510(k) Report

510(k) · Cleared

Cleared

Air Solfy, Models as-4H, as-4H-O, as-4H-V, as-4H-OV, as-1,as-1-0,as-1-V, as-1-OV

K043497510(k) TraditionalCleared Mar 21, 200594-day reviewClass I21 CFR 872.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

J. Morita USA, Inc. · EFB Handpiece, Air-Powered, Dental

Cleared on Mar 21, 2005 as substantially equivalent to K033812 (Sirona Dental Systems GmbH, 2004) after a 94-day review. Its family tree reaches back 2 generations to 1995.

Decided
Mar 21, 2005
Review
94 days
Class
Class I
Product code
EFB
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K944714 (1995). No later device cites it as a predicate yet.

  1. Root · 2 generations backK944714 W&H Corsair ScalerA-Dec, Inc. · 1995
  2. 1 generation backK033812 Siroair L Air ScalerSirona Dental Systems GmbH · 2004
  3. This deviceK043497 Air Solfy, Models as-4H, as-4H-O, as-4H-V, as-4H-OV…J. Morita USA, Inc. · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K944714W&H Corsair ScalerA-Dec, Inc.1995—
−1K033812Siroair L Air ScalerSirona Dental Systems GmbH2004—
0 (this device)K043497Air Solfy, Models as-4H, as-4H-O, as-4H-V, as-4H-OV, as-1,as-1-0,as-1-V, as-1-OVJ. Morita USA, Inc.2005—
FIG. 1 — Lineage of K043497, 1995–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EFB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EFB device

  1. #1 K262144 DIAMED Handpiece;DIAMED Airmotor;DIAMED…score 13.3 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033812Siroair L Air Scaler
Summary page 2
…ir Solfy is substantially equivalent to the general scaler from Sirona dental syatem , Inc(K#033812). Air Solfy has similar characteristics as intended us…
Sirona Dental Systems GmbH2004—

Also cleared against K033812: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 8.5 years on median.
  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K033812.

How does its category compare?

All EFB devices

EFB Handpiece, Air-Powered, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EFB

1in 2025

2007: 122008: 72009: 112010: 82011: 42012: 82013: 32014: 72015: 72016: 32017: 72018: 32019: 32020: 52021: 22022: 52023: 42024: 52025: 12026 (partial year): 4
2007high 12 (2007) · low 1 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EFB

209in 2024

2007: 61 days median2008: 97 days median2009: 120 days median2010: 116 days median2011: 168 days median2012: 130 days median2013: 207 days median2014: 200 days median2015: 296 days median2016: 205 days median2017: 246 days median2018: 210 days median2019: 348 days median2020: 259 days median2022: 430 days median2023: 158 days median2024: 209 days median2026 (partial year): 252 days median
2007high 430 (2022) · low 61 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EFB

No recall names EFB since 2007.

Adverse event reports per year · EFB

83in 2025

2007: 132008: 192009: 402010: 782011: 962012: 972013: 612014: 732015: 872016: 1222017: 1532018: 812019: 1172020: 942021: 1232022: 1572023: 1162024: 1042025: 83
2007high 157 (2022) · low 13 (2007)2025

MAUDE reports naming product code EFB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071261013
2008797019
200911120040
20108116078
20114168096
20128130097
20133207061
20147200073
20157296087
201632050122
201772460153
20183210081
201933480117
20205259094
20212—0123
202254300157
202341580116
202452090104
20251—083
202642520—

What is it indicated for?

The Air Solfy is a dental air-powered handpiece scaler and tips that can remove calculus deposits from the teeth by application of an air-powered vibrating scaler tip to the teeth during dental cleaning and periodontal therapy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K043497: Air Solfy, Models as-4H, as-4H-O, as-4H-V, as-4H-OV, as-1,as-1-0,as-1-V, as-1-OV.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K043497

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026