510(k) Report

510(k) · Cleared

Recalled · 2007

Spirit, Model Has

K050153510(k) TraditionalCleared Apr 15, 200581-day reviewClass II21 CFR 868.5655Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Caire, Inc. · BYJ Unit, Liquid-Oxygen, Portable

Cleared on Apr 15, 2005 as substantially equivalent to K013251 (Caire, Inc., 2001) after an 81-day review. Its family tree reaches back 3 generations to 1994. 1 of the 7 devices in its family, counting itself, has a Class I recall. 1 later device descends from it. It has been recalled once.

Decided
Apr 15, 2005
Review
81 days
Class
Class II
Product code
BYJ
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to K933930 (1994). 5 ancestors in all, the oldest K800742 (1980). 1 later device descends from it, 1 citing it directly. 1 of the 7 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1983: 1 other ancestor1980: 1 other ancestor, 1 with a Class I recall12007: 1 descendant clearedK933930 · Puritan-Bennett Companion 550 Liquid Oxygen Portable Unit · Puritan Bennett Corp. · 1994K993220 · Puritan-Bennett Helios Portable Liquid Oxygen System · Puritan Bennett Corp. · 1999K013251 · Spirit 300 · Caire, Inc. · 200119801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors, 1 with a Class I recall1 1 generation forward: 1 descendant K013251 · Spirit 300 · Caire, Inc. · 2001K993220 · Puritan-Bennett Helios Portable Liquid Oxygen System · Puritan Bennett Corp. · 1999K933930 · Puritan-Bennett Companion 550 Liquid Oxygen Portable Unit · Puritan Bennett Corp. · 19940
  1. Root · 3 generations backK933930 Puritan-Bennett Companion 550 Liquid Oxygen Portable UnitPuritan Bennett Corp. · 1994
  2. 2 generations backK993220 Puritan-Bennett Helios Portable Liquid Oxygen SystemPuritan Bennett Corp. · 1999
  3. 1 generation backK013251 Spirit 300Caire, Inc. · 2001
  4. This deviceK050153 Spirit, Model HasCaire, Inc. · 2005
  5. Descendant · cites it directly · 0 of its ownK071461 Model 300D Home Oxygen LiquefierCopd Partners, Inc. · 2007

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K071461Model 300D Home Oxygen LiquefierCopd Partners, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K933930Puritan-Bennett Companion 550 Liquid Oxygen Portable UnitPuritan Bennett Corp.1994—
−2K993220Puritan-Bennett Helios Portable Liquid Oxygen SystemPuritan Bennett Corp.1999—
−1K013251Spirit 300Caire, Inc.2001—
0 (this device)K050153Spirit, Model HasCaire, Inc.2005—
+1K071461Model 300D Home Oxygen LiquefierCopd Partners, Inc.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198011
198310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K050153, 1994–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013251Spirit 300
Summary page 1
…ame: Portable Liquid Oxygen Unit CFR Section: 868.5655 Product Code: BYJ Predicate Device: Spirit 300 [FDA 510(k) #K013251] Device Description: The Spirit 300 HAS is a small, lightweight, liquid oxygen portable unit. The unit consists of a vacuum-insu…
Caire, Inc.2001—

Also cleared against K013251: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071461Model 300D Home Oxygen LiquefierCopd Partners, Inc.20070

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 23, 2007Not classifiedZ-1716-2008Device DesignMoisture ingress into the electronic liquid level indicator may cause inaccurate liquid oxygen level readings. The oxygen could run out without the patient knowledge.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K800742Liberator/Stroller II SystemCryogenic Assoc. · 1980 · 2 generations back · ◆ in the 1980 ancestors bar of FIG. 14 Class I recalls

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 3.3 years on median.
  • 1 of the 5 ancestors has a recall of any class; 1 has a Class I recall.
  • Of its descendants, K071461 (Copd Partners, Inc., 2007) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K013251.

How does its category compare?

All BYJ devices

BYJ Unit, Liquid-Oxygen, Portable: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BYJ

1in 2013

2007: 22008: 32010: 12011: 12012: 12013: 1
2007high 3 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BYJ

164in 2008

2008: 164 days median
2007high 164 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BYJ

4in 2022

2007: 12022: 4, 4 Class I
2007high 4 (2022) · low 0 (2008)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · BYJ

1in 2025

2007: 242008: 332009: 122010: 242011: 152012: 112013: 222014: 252015: 342016: 192017: 182018: 212019: 242020: 392021: 72022: 42023: 102024: 102025: 1
2007high 39 (2020) · low 1 (2025)2025

MAUDE reports naming product code BYJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—124
20083164033
20090—012
20101—024
20111—015
20121—011
20131—022
20140—025
20150—034
20160—019
20170—018
20180—021
20190—024
20200—039
20210—07
20220—4 (4)4
20230—010
20240—010
20250—01
20260—0—

What is it indicated for?

The Spirit 300 HAS will provide a source of supplemental oxygen for ambulatory home healthcare patients, by vaporizing 93% liquid oxygen and then dispensing it to the patient via an integral electronic conserving device. The Spirit 300 HAS is intended to be transfilled only by the In-X Corporation's Home-Away System. The Spirit 300 HAS is neither a life-sustaining nor life-supporting device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K050153: Spirit, Model Has.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K050153

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026