510(k) Report

510(k) · Cleared

Cleared

Modification to: Spirit

K080023510(k) SpecialCleared Jun 16, 2008164-day reviewClass II21 CFR 868.5655

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Caire, Inc. · BYJ Unit, Liquid-Oxygen, Portable

Cleared on Jun 16, 2008 as substantially equivalent to K013251 (Caire, Inc., 2001) after a 164-day review. Its family tree reaches back 3 generations to 1994. 1 of the 6 devices in its family, counting itself, has a Class I recall.

Decided
Jun 16, 2008
Review
164 days
Class
Class II
Product code
BYJ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K933930 (1994). 5 ancestors in all, the oldest K800742 (1980). No later device cites it as a predicate yet. 1 of the 6 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 1983: 1 other ancestor1980: 1 other ancestor, 1 with a Class I recall1K933930 · Puritan-Bennett Companion 550 Liquid Oxygen Portable Unit · Puritan Bennett Corp. · 1994K993220 · Puritan-Bennett Helios Portable Liquid Oxygen System · Puritan Bennett Corp. · 1999K013251 · Spirit 300 · Caire, Inc. · 20011980198519901995200020052010
  1. Root · 3 generations backK933930 Puritan-Bennett Companion 550 Liquid Oxygen Portable UnitPuritan Bennett Corp. · 1994
  2. 2 generations backK993220 Puritan-Bennett Helios Portable Liquid Oxygen SystemPuritan Bennett Corp. · 1999
  3. 1 generation backK013251 Spirit 300Caire, Inc. · 2001
  4. This deviceK080023 Modification to: SpiritCaire, Inc. · 2008

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K933930Puritan-Bennett Companion 550 Liquid Oxygen Portable UnitPuritan Bennett Corp.1994—
−2K993220Puritan-Bennett Helios Portable Liquid Oxygen SystemPuritan Bennett Corp.1999—
−1K013251Spirit 300Caire, Inc.2001—
0 (this device)K080023Modification to: SpiritCaire, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198011
198310
FIG. 1 — Lineage of K080023, 1994–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013251Spirit 300
Summary page 1
…CFR Section: 865.5655 Regulation Description: Portable Liquid Oxygen Unit Predicate Device: Spirit 300 [FDA 510(K) K013251] Device Description: The spirit 300 is a small, lightweight, liquid oxygen portable unit. The unit consists of a vacuum ins…
Caire, Inc.2001—

Also cleared against K013251: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K800742Liberator/Stroller II SystemCryogenic Assoc. · 1980 · 2 generations back · ◆ in the 1980 ancestors bar of FIG. 14 Class I recalls

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 5.6 years on median.
  • 1 of the 5 ancestors has a recall of any class; 1 has a Class I recall.
  • 2 other devices also cite its predicate K013251.

How does its category compare?

All BYJ devices

BYJ Unit, Liquid-Oxygen, Portable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · BYJ

1in 2013

2007: 22008: 32010: 12011: 12012: 12013: 1
2007high 3 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BYJ

164in 2008

2008: 164 days median
2007high 164 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BYJ

4in 2022

2007: 12022: 4, 4 Class I
2007high 4 (2022) · low 0 (2008)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · BYJ

1in 2025

2007: 242008: 332009: 122010: 242011: 152012: 112013: 222014: 252015: 342016: 192017: 182018: 212019: 242020: 392021: 72022: 42023: 102024: 102025: 1
2007high 39 (2020) · low 1 (2025)2025

MAUDE reports naming product code BYJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—124
20083164033
20090—012
20101—024
20111—015
20121—011
20131—022
20140—025
20150—034
20160—019
20170—018
20180—021
20190—024
20200—039
20210—07
20220—4 (4)4
20230—010
20240—010
20250—01
20260—0—

What is it indicated for?

The Caire Spirit 300 will provide a source of supplemental oxygen for ambulatory

healthcare patients by vaporizing medical grade liquid oxygen and then

dispensing it to the, patient via an integral electronic conserving device (digital

oxygen conserving device-DOCID). The Spirit 300 is neither a life sustaining nor

life supporting device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080023: Modification to: Spirit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K080023

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026