510(k) Report

510(k) · Cleared

Cleared

Balance Hip System

K050251510(k) TraditionalCleared May 27, 2005113-day reviewClass III21 CFR 888.3330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomet, Inc. · KWA Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)

Cleared on May 27, 2005 as substantially equivalent to K921181 (Biomet, Inc., 1994) and 3 other predicates after a 113-day review. Its family tree reaches back 3 generations to 1985. 2 later devices descend from it.

Decided
May 27, 2005
Review
113 days
Class
Class III
Product code
KWA
Recalls
None
Predicates
4

Its longest line of descent runs back 3 generations to K854046 (1985). 19 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 2 other ancestors1994: 7 other ancestors2000: 1 other ancestor1999: 2 other ancestors1998: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor1986: 1 other ancestor2014: 1 descendant cleared2015: 1 descendant clearedK854046 · Conical Collar Hip Prosthesis · Kirschner Medical Corp. · 1985K960303 · Fenning Femoral Component · Biomet, Inc. · 1996K030055 · Mallory/Head Total Hip System; HA Mallory/Head Total Hip System; BI-Metric Femoral Components · Biomet, Inc. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 4 other ancestors3 generations back: 9 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant K030055 · Mallory/Head Total Hip System; HA Mallory/Head Total Hip System; BI-Metric Femoral Components · Biomet, Inc. · 2003 · recalledK960303 · Fenning Femoral Component · Biomet, Inc. · 1996K854046 · Conical Collar Hip Prosthesis · Kirschner Medical Corp. · 19850
  1. Root · 3 generations backK854046 Conical Collar Hip ProsthesisKirschner Medical Corp. · 1985
  2. 2 generations backK960303 Fenning Femoral ComponentBiomet, Inc. · 1996
  3. 1 generation backK030055 Mallory/Head Total Hip System; HA Mallory/Head Total Hip System…Biomet, Inc. · 2003 · Recalled
  4. This deviceK050251 Balance Hip SystemBiomet, Inc. · 2005
  5. Descendant · cites it directly · 1 of its ownK143009 Echo Bi-Metric Microplasty Hip SystemBiomet, Inc. · 2014
  6. Descendant · 2 generations on · 0 of its ownK150503 Echo Bi-Metric Microplasty Line ExtensionBiomet, Inc. · 2015

Most influential descendants

Showing 2 of 2 · See all
  • K143009Echo Bi-Metric Microplasty Hip SystemBiomet, Inc. · 2014 · cites it directly1descendant
  • K150503Echo Bi-Metric Microplasty Line ExtensionBiomet, Inc. · 2015 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K854046Conical Collar Hip ProsthesisKirschner Medical Corp.1985—
−2K960303Fenning Femoral ComponentBiomet, Inc.1996—
−1K030055Mallory/Head Total Hip System; HA Mallory/Head Total Hip System; BI-Metric…Biomet, Inc.20033
0 (this device)K050251Balance Hip SystemBiomet, Inc.2005—
+1K143009Echo Bi-Metric Microplasty Hip SystemBiomet, Inc.2014—
+2K150503Echo Bi-Metric Microplasty Line ExtensionBiomet, Inc.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199470
199510
199610
199720
199810
199920
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201510
FIG. 1 — Lineage of K050251, 1985–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K921181Mallory-Head Total Hip System
Summary page 2
…176 Legally Marketed Devices To Which Substantial Equivalence Is Claimed: Mallory - Head® Total Hip System - Biomet Inc. (K921181, K030055) Mayo® Conservative Hip Prosthesis - Zimmer Inc. (K943230) Bi-Metric® Total Hip Syst…
Biomet, Inc.1994—
*K030055Mallory/Head Total Hip System; HA Mallory/Head Total Hip System; BI-Metric Femoral…
Summary page 2
…176 Legally Marketed Devices To Which Substantial Equivalence Is Claimed: Mallory - Head® Total Hip System - Biomet Inc. (K921181, K030055) Mayo® Conservative Hip Prosthesis - Zimmer Inc. (K943230) Bi-Metric® Total Hip System - Biom…
Biomet, Inc.20033
*K943230Mayo Hip Prosthesis
Summary page 2
…lence Is Claimed: Mallory - Head® Total Hip System - Biomet Inc. (K921181, K030055) Mayo® Conservative Hip Prosthesis - Zimmer Inc. (K943230) Bi-Metric® Total Hip System - Biomet Inc. (K921224, K030055)…
Mayo Clinic1997—
*K921224Bimetric Total Hip System
Summary page 2
…- Biomet Inc. (K921181, K030055) Mayo® Conservative Hip Prosthesis - Zimmer Inc. (K943230) Bi-Metric® Total Hip System - Biomet Inc. (K921224, K030055) stems available Device Descr…
Biomet, Inc.1994—

Also cleared against K921181: 5 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K143009Echo Bi-Metric Microplasty Hip SystemBiomet, Inc.20141

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 2 companies; a new generation was cleared every 7.1 years on median.
  • 2 of the 19 ancestors have a recall of any class.
  • Of its descendants, K143009 (Biomet, Inc., 2014) has gone furthest, with 1 descendant of its own.
  • 5 other devices also cite its predicate K921181.

How does its category compare?

All KWA devices

KWA Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWA

4in 2012

2007: 82008: 92009: 72010: 62011: 112012: 4
2007high 11 (2011) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWA

76in 2012

2007: 74 days median2008: 57 days median2009: 139 days median2010: 167 days median2011: 101 days median2012: 76 days median
2007high 167 (2010) · low 57 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWA

19in 2023

2008: 132010: 842011: 282012: 212013: 12016: 12017: 12018: 12019: 22020: 12023: 19
2007high 84 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWA

1,216in 2025

2007: 2132008: 7622009: 8202010: 3,3482011: 17,7372012: 24,6012013: 20,0202014: 16,4942015: 12,3392016: 7,8722017: 6,8472018: 6,3882019: 7,6282020: 4,5382021: 2,0642022: 1,6172023: 1,4742024: 1,1682025: 1,216
2007high 24,601 (2012) · low 213 (2007)2025

MAUDE reports naming product code KWA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20078740213
200895713762
200971390820
20106167843,348
2011111012817,737
20124762124,601
20130—120,020
20140—016,494
20150—012,339
20160—17,872
20170—16,847
20180—16,388
20190—27,628
20200—14,538
20210—02,064
20220—01,617
20230—191,474
20240—01,168
20250—01,216
20260—0—

What is it indicated for?

1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis. 2. Rheumatoid arthritis 3. Correction of functional deformity 4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques. 5. Revision of previously failed total hip arthroplasty. Balance® Hip System Femoral Stems are intended for uncemented use only. 1.…

Read the full statement (117 words)

1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis.

2. Rheumatoid arthritis

3. Correction of functional deformity

4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques.

5. Revision of previously failed total hip arthroplasty.

Balance® Hip System Femoral Stems are intended for uncemented use only.

1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis.

2. Rheumatoid arthritis

3. Correction of functional deformity

4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques.

5. Revision of previously failed femoral head resurfacing components.

Balance® Hip System Microplasty® Stems are intended for uncemented use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K050251: Balance Hip System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050251

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026