510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Advia Ims Lithium Assay

K050374510(k) TraditionalCleared Jun 15, 2005121-day reviewClass II21 CFR 862.3560Recalls 6

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bayer Healthcare, LLC · NDW Assay, Porphyrin, Spectrophotometry, Lithium

Cleared on Jun 15, 2005 after a 121-day review. The FDA summary names its predicate without a number. 3 later devices descend from it. It has been recalled 6 times.

Decided
Jun 15, 2005
Review
121 days
Class
Class II
Product code
NDW
Recalls
6
Predicates
0

3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2024: 1 descendant cleared2025: 1 descendant cleared20052010201520202025
  1. This deviceK050374 Advia Ims Lithium AssayBayer Healthcare, LLC · 2005
  2. Descendant · cites it directly · 2 of its ownK161494 Atellica CH Creatinine_2 (Crea_2), Atellica CH Chemistry Calibrator…Siemens Healthcare Diagnostics, Inc. · 2016 · Recalled
  3. Descendant · 2 generations on · 1 of its ownK242685 Atellica® CH Creatinine_3 (Crea3)Siemens Healthcare Diagnostics, Inc. · 2024
  4. Descendant · 3 generations on · 0 of its ownK251058 Tru Kidney Health Test Panel; Tru AnalyzerTruvian Health · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K161494Atellica CH Creatinine_2 (Crea_2), Atellica CH Chemistry Calibrator (CHEM CAL)Siemens Healthcare Diagnostics, Inc. · 2016 · cites it directly2descendants
  • K242685Atellica® CH Creatinine_3 (Crea3)Siemens Healthcare Diagnostics, Inc. · 2024 · 2 generations on1descendant
  • K251058Tru Kidney Health Test Panel; Tru AnalyzerTruvian Health · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K050374Advia Ims Lithium AssayBayer Healthcare, LLC2005—
+1K161494Atellica CH Creatinine_2 (Crea_2), Atellica CH Chemistry Calibrator (CHEM CAL)Siemens Healthcare Diagnostics, Inc.20161
+2K242685Atellica® CH Creatinine_3 (Crea3)Siemens Healthcare Diagnostics, Inc.2024—
+3K251058Tru Kidney Health Test Panel; Tru AnalyzerTruvian Health2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
202410
202510
FIG. 1 — Lineage of K050374, 2005–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NDW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—ThermoTrace Lithium
Named without a submission number
—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161494Atellica CH Creatinine_2 (Crea_2), Atellica CH Chemistry Calibrator (CHEM CAL)Siemens Healthcare Diagnostics, Inc.20162

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 19, 2022Class IIZ-0105-2023Under Investigation by firmPotential for falsely elevated LITH_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially…
Sep 19, 2022Class IIZ-0104-2023Under Investigation by firmPotential for falsely elevated LITH_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially…
Feb 9, 2022Class IIZ-0931-2022Device DesignSiemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.
Jun 5, 2020Class IIZ-2430-2020Nonconforming Material/ComponentCalibration errors have been observed with the Total and Direct Bilirubin assays when using Chemistry Calibrator lot 534177 for ADVIA Chemistry and lot 534179 for Atellica CH.
Oct 7, 2016Class IIZ-0589-2017Under Investigation by firmSiemens has confirmed that the DBIL_2 Assigned Calibrator Values (ACV) currently assigned to the affected lots may cause, on average, a positive proportional bias of approximately 41% on patient samples compared to the reference method…
Sep 24, 2013Class IIZ-0365-2014Under Investigation by firmSiemens Healthcare Diagnostics is conducting a field correction for Siemens Chemistry Calibrator Lots 090445B and 090445C on the ADVIA 1200, 1650, 1800, and 2400 Chemistry Systems. The System Specific Values (SSVs) for the Direct…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K161494 (Siemens Healthcare Diagnostics, Inc., 2016) has gone furthest, with 2 descendants of its own.

How does its category compare?

All NDW devices

NDW Assay, Porphyrin, Spectrophotometry, Lithium: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NDW

1in 2025

2007: 22008: 12011: 12025: 1
2007high 2 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NDW

Too few NDW 510(k)s in any year since 2007 to give a median.

Recalls per year · NDW

3in 2022

2022: 3
2007high 3 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NDW

2in 2025

2009: 12010: 12011: 32013: 22019: 12023: 12024: 22025: 2
2007high 3 (2011) · low 0 (2007)2025

MAUDE reports naming product code NDW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20090—01
20100—01
20111—03
20120—00
20130—02
20140—00
20150—00
20160—00
20170—00
20180—00
20190—01
20200—00
20210—00
20220—30
20230—01
20240—02
20251—02
20260—0—

What is it indicated for?

The Bayer ADVIA IMS Lithium (LITH) method is an in vitro diagnostic device intended to measure lithium in human serum and plasma. Such measurements are used as an aid in monitoring lithium levels during the treatment of bipolar disorder.

The Assayed Chemistry Control 1 and Control 2 are for in vitro diagnostic use to monitor the performance of chemistry systems, including the ADVIA®IMS, ADVIA® Chemistry, and Technicon RA® and opeRA systems.

The Chemistry Calibrator is for in vitro diagnostic use in the calibration of chemistry assays on chemistry systems, including the ADVIA® IMS, ADVIA® Chemistry, and Technicon RA® and opeRA systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K050374: Advia Ims Lithium Assay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050374

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026