510(k) · Cleared
ClearedAccent
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Air Techniques, Inc. · MUH System, X-Ray, Extraoral Source, Digital
Cleared on May 26, 2005 after a 70-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 55 later devices descend from it.
- Decided
- May 26, 2005
- Review
- 70 days
- Class
- Class II
- Product code
- MUH
- Recalls
- None
- Predicates
- 0
55 later devices descend from it, 5 citing it directly.
- This deviceK050693 AccentAir Techniques, Inc. · 2005
- Descendant · cites it directly · 44 of its ownK070505 Krystal-X WifiOwandy · 2007
- Descendant · 2 generations on · 43 of its ownK081722 YSIOSiemens Medical Solutions USA, Inc. · 2008 · Recalled
- Descendant · 3 generations on · 32 of its ownK121513 Multix FusionSiemens Medical Solution · 2012 · Recalled
- Descendant · 3 generations on · 23 of its ownK133259 Ysio MaxSiemens Medical Solutions USA, Inc. · 2014 · Recalled
- Descendant · 4 generations on · 18 of its ownK142049 Multix Fusion VA30 & VA40Siemens Medical Solutions USA, Inc. · 2014
Showing 5 of 55 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 55 · See all- K070505Krystal-X WifiOwandy · 2007 · cites it directly44descendants
- K081722YSIOSiemens Medical Solutions USA, Inc. · 2008 · 2 generations on43descendants
- K121513Multix FusionSiemens Medical Solution · 2012 · 3 generations on32descendants
- K133259Ysio MaxSiemens Medical Solutions USA, Inc. · 2014 · 3 generations on23descendants
- K142049Multix Fusion VA30 & VA40Siemens Medical Solutions USA, Inc. · 2014 · 4 generations on18descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K050693 | Accent | Air Techniques, Inc. | 2005 | — |
| +1 | K070505 | Krystal-X Wifi | Owandy | 2007 | — |
| +2 | K081722 | YSIO | Siemens Medical Solutions USA, Inc. | 2008 | 11 |
| +3 | K121513 | Multix Fusion | Siemens Medical Solution | 2012 | 4 |
| +3 | K133259 | Ysio Max | Siemens Medical Solutions USA, Inc. | 2014 | 7 |
| +4 | K142049 | Multix Fusion VA30 & VA40 | Siemens Medical Solutions USA, Inc. | 2014 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 2 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 2 | 0 |
| 2012 | 1 | 0 |
| 2014 | 3 | 0 |
| 2015 | 2 | 0 |
| 2016 | 3 | 0 |
| 2017 | 1 | 0 |
| 2018 | 3 | 0 |
| 2019 | 6 | 0 |
| 2020 | 4 | 0 |
| 2021 | 3 | 0 |
| 2022 | 4 | 0 |
| 2023 | 4 | 0 |
| 2024 | 3 | 0 |
| 2025 | 5 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MUH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MUH device
- #1 K242778 X Sensor (Model: IOS-A15IF, HDI-15DGF)score 16.0 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (55)
See all 555 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K070505 (Owandy, 2007) has gone furthest, with 44 descendants of its own.
How does its category compare?
All MUH devicesMUH System, X-Ray, Extraoral Source, Digital: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MUH
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MUH
159in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MUH
1in 2015
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MUH
1in 2025
MAUDE reports naming product code MUH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 11 | 48 | 0 | 0 |
| 2008 | 8 | 64 | 1 | 0 |
| 2009 | 9 | 88 | 2 | 12 |
| 2010 | 9 | 174 | 0 | 9 |
| 2011 | 10 | 89 | 0 | 0 |
| 2012 | 9 | 81 | 0 | 5 |
| 2013 | 9 | 172 | 1 | 1 |
| 2014 | 8 | 168 | 1 | 5 |
| 2015 | 12 | 111 | 1 | 3 |
| 2016 | 6 | 47 | 0 | 1 |
| 2017 | 9 | 84 | 0 | 4 |
| 2018 | 3 | 29 | 0 | 10 |
| 2019 | 5 | 64 | 0 | 6 |
| 2020 | 5 | 36 | 0 | 0 |
| 2021 | 10 | 80 | 0 | 1 |
| 2022 | 7 | 57 | 0 | 0 |
| 2023 | 11 | 57 | 0 | 1 |
| 2024 | 4 | 144 | 0 | 0 |
| 2025 | 3 | 159 | 0 | 1 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Accent Sensor is a digital x-ray sensor system for human and non human use in dental, medical and veterinary applications. It is used to provide instant X-ray images, typically of teeth, bone and surrounding tissues.
Accent replaces standard X-ray film and/or phosphor plate technology.
The X-ray tube (not part of this product) is pointed at the sensor and activated. The X-ray energy is detected by the sensor and transmitted as data to the computer to which it is connected. The software (not part of this product) interprets the image as a gray scale image and displays it on the computer monitor for diagnosis.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K050693 · printed Nov 3, 2026
Cite this page
510(k) Report. “K050693: Accent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K050693
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026