510(k) Report

510(k) · Cleared

Cleared

Acumed Scapula Congruent Bone Plate System

K051083510(k) TraditionalCleared May 12, 200515-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Acumed, LLC · HRS Plate, Fixation, Bone

Cleared on May 12, 2005 as substantially equivalent to K012655 (Acu Med, Inc., 2001) and 1 other predicate after a 15-day review. Its family tree reaches back 3 generations to 2000. 2 later devices descend from it.

Decided
May 12, 2005
Review
15 days
Class
Class II
Product code
HRS
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K000684 (2000). 8 ancestors in all, the oldest K890939 (1989). 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2000: 1 other ancestor1995: 1 other ancestor1991: 1 other ancestor1989: 1 other ancestor2025: 1 descendant cleared2024: 1 descendant clearedK000684 · Small Fragment Dynamic Compression Locking (DCL) System · Synthes (Usa) · 2000 · recalled×2: 2 generations cleared close together, K011335 (2001), K012655 (2001) 1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 5 other ancestors 1 generation forward: 2 descendants K012655 · Congruent Bone Plate System · Acu Med, Inc. · 2001 · recalledK011335 · Synths One-Third Tubular DCL Plate · Synthes (Usa) · 2001 · recalledK000684 · Small Fragment Dynamic Compression Locking (DCL) System · Synthes (Usa) · 2000 · recalled0
  1. Root · 3 generations backK000684 Small Fragment Dynamic Compression Locking (DCL) SystemSynthes (Usa) · 2000 · Recalled
  2. 2 generations backK011335 Synths One-Third Tubular DCL PlateSynthes (Usa) · 2001 · Recalled
  3. 1 generation backK012655 Congruent Bone Plate SystemAcu Med, Inc. · 2001 · Recalled
  4. This deviceK051083 Acumed Scapula Congruent Bone Plate SystemAcumed, LLC · 2005
  5. Descendant · cites it directly · 0 of its ownK243275 Equinoxe® Scapula Fracture SystemExactech, Inc. · 2025
  6. Descendant · cites it directly · 0 of its ownK240181 Clavicle and Scapula SystemAuxein Medical Pvt., Ltd. · 2024

Most influential descendants

Showing 2 of 2 · See all
  • K243275Equinoxe® Scapula Fracture SystemExactech, Inc. · 2025 · cites it directly0descendants
  • K240181Clavicle and Scapula SystemAuxein Medical Pvt., Ltd. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K000684Small Fragment Dynamic Compression Locking (DCL) SystemSynthes (Usa)20001
−2K011335Synths One-Third Tubular DCL PlateSynthes (Usa)20012
−1K012655Congruent Bone Plate SystemAcu Med, Inc.200116
0 (this device)K051083Acumed Scapula Congruent Bone Plate SystemAcumed, LLC2005—
+1K243275Equinoxe® Scapula Fracture SystemExactech, Inc.2025—
+1K240181Clavicle and Scapula SystemAuxein Medical Pvt., Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199110
199510
200010
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
202510
FIG. 1 — Lineage of K051083, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRS device

  1. #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012655Congruent Bone Plate System
Summary page 1
…Class II, 21 CFR 888.3030 Device Product Code: HIRS Legally Marketed Equivalent Device(s): Acumed LLC Congruent Bone Plate System K012655 Synthes (USA) One-Third Tubular DCL Plate K01 1335 Device Description: The Acumed S…
Acu Med, Inc.200116
*K011335Synths One-Third Tubular DCL Plate
Summary page 1
…arketed Equivalent Device(s): Acumed LLC Congruent Bone Plate System K012655 Synthes (USA) One-Third Tubular DCL Plate K01 1335 Device Description: The Acumed Scapula Congruent Bone Plate System consists of bone plates and screws for fractures, fusions, an…
Synthes (Usa)20012

Also cleared against K012655: 27 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243275Equinoxe® Scapula Fracture SystemExactech, Inc.20250
K240181Clavicle and Scapula SystemAuxein Medical Pvt., Ltd.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 1.2 years on median.
  • 4 of the 8 ancestors have a recall of any class.
  • Of its descendants, K243275 (Exactech, Inc., 2025) has gone furthest, with 0 descendants of its own.
  • 27 other devices also cite its predicate K012655.

How does its category compare?

All HRS devices

HRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HRS

54in 2025

2007: 352008: 352009: 472010: 492011: 432012: 592013: 562014: 762015: 562016: 442017: 572018: 402019: 462020: 482021: 402022: 472023: 402024: 542025: 542026 (partial year): 51
2007high 76 (2014) · low 35 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRS

90in 2025

2007: 63 days median2008: 87 days median2009: 85 days median2010: 100 days median2011: 88 days median2012: 106 days median2013: 89 days median2014: 57 days median2015: 97 days median2016: 109 days median2017: 122 days median2018: 116 days median2019: 89 days median2020: 88 days median2021: 87 days median2022: 144 days median2023: 120 days median2024: 96 days median2025: 90 days median2026 (partial year): 82 days median
2007high 144 (2022) · low 57 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRS

1in 2025

2007: 22008: 112009: 32010: 162011: 52012: 42013: 112015: 72016: 52017: 32018: 22019: 252020: 12021: 92022: 32023: 12025: 12026 (partial year): 3
2007high 25 (2019) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRS

2,306in 2025

2007: 3392008: 3112009: 4352010: 4912011: 7732012: 1,6632013: 2,6432014: 2,4132015: 3,0952016: 2,2762017: 2,2202018: 2,6632019: 3,3592020: 2,7902021: 2,4422022: 1,7002023: 2,0492024: 1,8492025: 2,306
2007high 3,359 (2019) · low 311 (2008)2025

MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735632339
2008358711311
200947853435
20104910016491
201143885773
20125910641,663
20135689112,643
2014765702,413
2015569773,095
20164410952,276
20175712232,220
20184011622,663
20194689253,359
2020488812,790
2021408792,442
20224714431,700
20234012012,049
2024549601,849
2025549012,306
202651823—

What is it indicated for?

The Acumed Scapula Congruent Bone Plate System provides fixation during fractures, fusions, and osteotomies for the scapula,

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K051083: Acumed Scapula Congruent Bone Plate System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K051083

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026