510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Acumatch a-Series Connexion GXL Enhanced Crosslinked Polythylene

K051556510(k) SpecialCleared Sep 6, 200585-day reviewClass II21 CFR 888.3358Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Exactech, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Cleared on Sep 6, 2005 as substantially equivalent to K993082 (Exactech, Inc., 1999) and 2 other predicates after an 85-day review. Its family tree reaches back 5 generations to 1994. 60 later devices descend from it. It has been recalled 12 times.

Decided
Sep 6, 2005
Review
85 days
Class
Class II
Product code
LPH
Recalls
12
Predicates
3

Its longest line of descent runs back 5 generations to K931641 (1994). 19 ancestors in all, the oldest K862234 (1986). 60 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor1999: 3 other ancestors2000: 3 other ancestors1996: 2 other ancestors1994: 2 other ancestors1993: 2 other ancestors1986: 1 other ancestor2018: 4 descendants cleared2007: 1 descendant cleared2013: 1 descendant cleared2010: 2 descendants cleared2015: 3 descendants cleared2019: 8 descendants cleared2014: 4 descendants cleared2012: 2 descendants cleared2022: 4 descendants cleared2025: 5 descendants cleared2021: 3 descendants cleared2020: 3 descendants cleared2023: 3 descendants cleared2026: 8 descendants cleared2017: 2 descendants cleared2016: 1 descendant cleared2024: 6 descendants clearedK931641 · Porocoat Porous Coating · Depuy, Inc. · 1994K003800 · Aml Hip Prosthesis · DePuy Orthopaedics, Inc. · 2001K012364 · Aml Hip Prosthesis · DePuy Orthopaedics, Inc. · 2001K030236 · Acumatch P-Series Porous Press-Fit Femoral Component · Exactech, Inc. · 2003K041906 · Exactech 12/14 Total Hip System · Exactech, Inc. · 2004 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 8 other ancestors3 generations back: 3 other ancestors4 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 5 descendants4 generations forward: 22 descendants5 generations forward: 19 descendants6 generations forward: 5 descendants7 generations forward: 2 descendants K041906 · Exactech 12/14 Total Hip System · Exactech, Inc. · 2004 · recalledK030236 · Acumatch P-Series Porous Press-Fit Femoral Component · Exactech, Inc. · 2003K012364 · Aml Hip Prosthesis · DePuy Orthopaedics, Inc. · 2001K003800 · Aml Hip Prosthesis · DePuy Orthopaedics, Inc. · 2001K931641 · Porocoat Porous Coating · Depuy, Inc. · 1994−50+5
  1. Root · 5 generations backK931641 Porocoat Porous CoatingDepuy, Inc. · 1994
  2. 4 generations backK003800 Aml Hip ProsthesisDePuy Orthopaedics, Inc. · 2001
  3. 3 generations backK012364 Aml Hip ProsthesisDePuy Orthopaedics, Inc. · 2001
  4. 2 generations backK030236 Acumatch P-Series Porous Press-Fit Femoral ComponentExactech, Inc. · 2003
  5. 1 generation backK041906 Exactech 12/14 Total Hip SystemExactech, Inc. · 2004 · Recalled
  6. This deviceK051556 Acumatch a-Series Connexion GXL Enhanced Crosslinked PolythyleneExactech, Inc. · 2005
  7. Descendant · cites it directly · 59 of its ownK070479 Exactech Novation Crown Cup and LinersExactech, Inc. · 2007 · Recalled
  8. Descendant · 2 generations on · 53 of its ownK102975 Novation Crown Cup with Integrip Acetabular Shell, Cluster-HoleExactech, Inc. · 2010
  9. Descendant · 3 generations on · 36 of its ownK122798 Integrip Acetabular Shell, Integrip Revision Acetabular ShellExactech, Inc. · 2012
  10. Descendant · 3 generations on · 35 of its ownK140669 G7 Osseoti Acetublar ShellsBiomet, Inc. · 2014
  11. Descendant · 3 generations on · 12 of its ownK112898 Delta TT Cups, Delta TT Liners, Bone ScrewsLima Corporate S.P.A. · 2012

Showing 5 of 60 descendants. See all descendants

Descendants cleared per year

2007: 12010: 22012: 22013: 12014: 42015: 32016: 12017: 22018: 42019: 82020: 32021: 32022: 42023: 32024: 62025: 52026: 8
2007high 8 (2019) · low 0 (2008)2026

Most influential descendants

Showing 5 of 60 · See all
  • K070479Exactech Novation Crown Cup and LinersExactech, Inc. · 2007 · cites it directly59descendants
  • K102975Novation Crown Cup with Integrip Acetabular Shell, Cluster-HoleExactech, Inc. · 2010 · 2 generations on53descendants
  • K122798Integrip Acetabular Shell, Integrip Revision Acetabular ShellExactech, Inc. · 2012 · 3 generations on36descendants
  • K140669G7 Osseoti Acetublar ShellsBiomet, Inc. · 2014 · 3 generations on35descendants
  • K112898Delta TT Cups, Delta TT Liners, Bone ScrewsLima Corporate S.P.A. · 2012 · 3 generations on12descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K931641Porocoat Porous CoatingDepuy, Inc.1994—
−4K003800Aml Hip ProsthesisDePuy Orthopaedics, Inc.2001—
−3K012364Aml Hip ProsthesisDePuy Orthopaedics, Inc.2001—
−2K030236Acumatch P-Series Porous Press-Fit Femoral ComponentExactech, Inc.2003—
−1K041906Exactech 12/14 Total Hip SystemExactech, Inc.20041
0 (this device)K051556Acumatch a-Series Connexion GXL Enhanced Crosslinked PolythyleneExactech, Inc.2005—
+1K070479Exactech Novation Crown Cup and LinersExactech, Inc.200716
+2K102975Novation Crown Cup with Integrip Acetabular Shell, Cluster-HoleExactech, Inc.2010—
+3K122798Integrip Acetabular Shell, Integrip Revision Acetabular ShellExactech, Inc.2012—
+3K140669G7 Osseoti Acetublar ShellsBiomet, Inc.2014—
+3K112898Delta TT Cups, Delta TT Liners, Bone ScrewsLima Corporate S.P.A.2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199320
199420
199620
199930
200030
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
201020
201220
201310
201440
201530
201610
201720
201840
201980
202030
202130
202240
202330
202460
202550
202680
FIG. 1 — Lineage of K051556, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LPH device

  1. #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993082Exactech Acumatch Integrated Hip System a-Series Porous Coated Acetabular Component
Summary page 3
…(k) # Clearance Product Date Code(s) AcuMatch® A-Series Porous Exactech K993082 11/19/1999 LPH & JDI Coated Acetabular Cornponent AcuMatch® A-Series and Exactech K040613 06/4/200…
Exactech, Inc.19992
*K040613Exactech Acumatch a-Series and MCS Acetabular Shells and Liners
Summary page 3
…) AcuMatch® A-Series Porous Exactech K993082 11/19/1999 LPH & JDI Coated Acetabular Cornponent AcuMatch® A-Series and Exactech K040613 06/4/2004 JDI, LPH & MCS Acetabular Shells & MEH Liners AcuMatch…
Exactech, Inc.20041
*K041906Exactech 12/14 Total Hip System
Summary page 3
…06/4/2004 JDI, LPH & MCS Acetabular Shells & MEH Liners AcuMatch® A-Series 36mm Exactech K041906 09/10/2004 LPH, LZO, Acetabular Liner, 12/14 MEH, LWJ Femoral Head an…
Exactech, Inc.20041

Also cleared against K993082: 8 other devices →

What descends from it? (60)

See all 60

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070479Exactech Novation Crown Cup and LinersExactech, Inc.200759
K173583Exactech® Novation® and AcuMatch® E-HXL Acetabular LinersExactech, Inc.20183

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 11, 2022Class IIZ-1728-2022Process controlSpecific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.
Jun 29, 2021Class IIZ-2121-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2122-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2117-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2131-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2118-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2112-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2113-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2116-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2124-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2133-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.
Jun 29, 2021Class IIZ-2114-2021Unknown/Undetermined by firmRisk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 1.3 years on median.
  • 4 of the 19 ancestors have a recall of any class.
  • Of its descendants, K070479 (Exactech, Inc., 2007) has gone furthest, with 59 descendants of its own.
  • 8 other devices also cite its predicate K993082.

How does its category compare?

All LPH devices

LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LPH

12in 2025

2007: 102008: 102009: 32010: 152011: 162012: 252013: 112014: 202015: 182016: 102017: 122018: 92019: 222020: 72021: 82022: 142023: 102024: 62025: 122026 (partial year): 8
2007high 25 (2012) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LPH

153in 2025

2007: 116 days median2008: 86 days median2009: 112 days median2010: 100 days median2011: 110 days median2012: 76 days median2013: 135 days median2014: 129 days median2015: 111 days median2016: 150 days median2017: 121 days median2018: 145 days median2019: 164 days median2020: 164 days median2021: 410 days median2022: 247 days median2023: 111 days median2024: 92 days median2025: 153 days median2026 (partial year): 256 days median
2007high 410 (2021) · low 76 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LPH

4in 2025

2007: 162008: 12009: 22010: 222011: 262012: 302013: 92014: 32015: 12016: 82017: 142018: 22019: 82020: 62021: 42022: 22023: 22024: 12025: 42026 (partial year): 2
2007high 30 (2012) · low 1 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LPH

6,163in 2025

2007: 5092008: 7062009: 1,1562010: 2,0072011: 3,3202012: 3,7852013: 5,0022014: 5,1632015: 5,8302016: 4,9002017: 5,3122018: 5,9542019: 7,1302020: 5,4292021: 5,9782022: 5,2232023: 5,3452024: 5,6262025: 6,163
2007high 7,130 (2019) · low 509 (2007)2025

MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071011616509
200810861706
2009311221,156
201015100222,007
201116110263,320
20122576303,785
20131113595,002
20142012935,163
20151811115,830
20161015084,900
201712121145,312
2018914525,954
20192216487,130
2020716465,429
2021841045,978
20221424725,223
20231011125,345
202469215,626
20251215346,163
202682562—

What is it indicated for?

AcuMatch® A-Series Enhanced Polyethylene Acetabular Liners are indicated for use in skeletally mature individuals undergoing primary surgery for total hip replacement due to osteoarthritis, rheumatoid arthritis, osteonecrosis, ankylosing spondylitis, congenital hip dysplasia, post-traumatic degenerative problems of the hip, and for treatment of proximal femoral fractures where prosthetic replacement is determined by the surgeon as the preferred treatment. Components of Exactech Hip Systems are also potentially indicated for revision of failed previous reconstructions where sufficient bone stock is present and to restore mobility resulting from previous fusion.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K051556: Acumatch a-Series Connexion GXL Enhanced Crosslinked Polythylene.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051556

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026