510(k) · Cleared
Recalled · Class II · 2020Magstim RAPID2, Magstim Super RAPID2, Models 3004-000, 3005-00
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
The Magstim Company, Ltd. · GWF Stimulator, Electrical, Evoked Response
Cleared on Dec 21, 2005 as substantially equivalent to K992911 (Magstim Corporation US, 2000) and 2 other predicates after a 166-day review. Its family tree reaches back 1 generation to 1991. 10 later devices descend from it. It has been recalled 2 times.
- Decided
- Dec 21, 2005
- Review
- 166 days
- Class
- Class II
- Product code
- GWF
- Recalls
- 2
- Predicates
- 3
Its longest line of descent runs back 1 generation to K905059 (1991). 3 ancestors in all. 10 later devices descend from it, 5 citing it directly.
- Root · 1 generation backK905059 High Speed Magnetic StimulatorCadwell Laboratories, Inc. · 1991
- This deviceK051864 Magstim RAPID2, Magstim Super RAPID2, Models 3004-000, 3005-00The Magstim Company, Ltd. · 2005
- Descendant · cites it directly · 7 of its ownK061645 Magpro, Model R30Tonica Elektronik A/S · 2006
- Descendant · cites it directly · 2 of its ownK091940 Magpro, Models R30 with Magoption, X100, X100 with MagoptionTonica Elektronik A/S · 2010
- Descendant · 2 generations on · 1 of its ownK160280 MagPro R20Tonica Elektronik A/S · 2016
- Descendant · 3 generations on · 0 of its ownK242345 Delphi StimulatorQuantalx Neuroscience · 2024
- Descendant · 2 generations on · 0 of its ownK192823 Mega-TMSSoterix Medical, Inc. · 2021
Showing 5 of 10 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 10 · See all- K061645Magpro, Model R30Tonica Elektronik A/S · 2006 · cites it directly7descendants
- K091940Magpro, Models R30 with Magoption, X100, X100 with MagoptionTonica Elektronik A/S · 2010 · cites it directly2descendants
- K160280MagPro R20Tonica Elektronik A/S · 2016 · 2 generations on1descendant
- K242345Delphi StimulatorQuantalx Neuroscience · 2024 · 3 generations on0descendants
- K192823Mega-TMSSoterix Medical, Inc. · 2021 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K905059 | High Speed Magnetic Stimulator | Cadwell Laboratories, Inc. | 1991 | — |
| 0 (this device) | K051864 | Magstim RAPID2, Magstim Super RAPID2, Models 3004-000, 3005-00 | The Magstim Company, Ltd. | 2005 | — |
| +1 | K061645 | Magpro, Model R30 | Tonica Elektronik A/S | 2006 | — |
| +1 | K091940 | Magpro, Models R30 with Magoption, X100, X100 with Magoption | Tonica Elektronik A/S | 2010 | — |
| +2 | K160280 | MagPro R20 | Tonica Elektronik A/S | 2016 | — |
| +3 | K242345 | Delphi Stimulator | Quantalx Neuroscience | 2024 | — |
| +2 | K192823 | Mega-TMS | Soterix Medical, Inc. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2010 | 1 | 0 |
| 2013 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2021 | 1 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GWF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GWF device
- #1 K263010 ISIS Headboxes, ISIS Neurostimulator, ISIS…score 17.5 · 19 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K992911 | Magstim RapidSummary page 1…005 2 Name of the Device: Magstim Rapid 2 and Magstim Super Rapid Identification of predicate device(s): Magstim Rapid K992911 Cadwell High Speed Magnetic Stimulator K905059… | 2000 |
| * | K905059 | High Speed Magnetic StimulatorSummary page 1…cation of predicate device(s): Magstim Rapid K992911 Cadwell High Speed Magnetic Stimulator K905059 Dantec Mag Pro K926516 Description of the device and modifications:… | 1991 |
| * | K926516 | Dantec Magnetic Stimulator MagproSummary page 1…Cadwell High Speed Magnetic Stimulator K905059 Dantec Mag Pro K926516 Description of the device and modifications:… | 1993 |
What descends from it? (10)
5 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Mar 23, 2020 | Class II | Z-1965-2020 | Nonconforming Material/Component | It was identified that there is a potential for the Stim Interconnecting high Voltage Cable located at the rear of the Rapid2 and Horizon power supply unit to fail. |
| Mar 23, 2020 | Class II | Z-1966-2020 | Nonconforming Material/Component | It was identified that there is a potential for the Stim Interconnecting high Voltage Cable located at the rear of the Rapid2 and Horizon power supply unit to fail. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 3 ancestors has a recall.
- Of its descendants, K061645 (Tonica Elektronik A/S, 2006) has gone furthest, with 7 descendants of its own.
How does its category compare?
All GWF devicesGWF Stimulator, Electrical, Evoked Response: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GWF
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GWF
92in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GWF
2so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · GWF
1,034in 2025
MAUDE reports naming product code GWF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 69 | 0 | 2 |
| 2008 | 2 | — | 0 | 1 |
| 2009 | 5 | 178 | 0 | 1 |
| 2010 | 3 | 269 | 0 | 4 |
| 2011 | 2 | — | 0 | 10 |
| 2012 | 4 | 230 | 1 | 44 |
| 2013 | 3 | 174 | 0 | 89 |
| 2014 | 1 | — | 0 | 25 |
| 2015 | 2 | — | 1 | 22 |
| 2016 | 1 | — | 0 | 20 |
| 2017 | 3 | 169 | 0 | 60 |
| 2018 | 0 | — | 0 | 58 |
| 2019 | 1 | — | 0 | 94 |
| 2020 | 1 | — | 0 | 65 |
| 2021 | 2 | — | 0 | 55 |
| 2022 | 2 | — | 0 | 45 |
| 2023 | 2 | — | 0 | 150 |
| 2024 | 4 | 92 | 0 | 854 |
| 2025 | 1 | — | 0 | 1,034 |
| 2026 | 3 | 125 | 2 | — |
What is it indicated for?
Peripheral Nerve Stimulation
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051864 · printed Nov 5, 2026
Cite this page
510(k) Report. “K051864: Magstim RAPID2, Magstim Super RAPID2, Models 3004-000, 3005-00.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K051864
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026