D732 Micro 27 PH.I.S.I.O. Adult Arterial Filter

K052717510(k) SpecialCleared Oct 20, 200521-day reviewClass II21 CFR 870.4260

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dideco S.R.L. · DTM Filter, Blood, Cardiopulmonary Bypass, Arterial Line

Cleared on Oct 20, 2005 as substantially equivalent to K952270 (Sorin Biomedical, Inc., 1995) and 1 other predicate after a 21-day review. Its family tree reaches back 1 generation to 1995.

Decided
Oct 20, 2005
Review
21 days
Class
Class II
Product code
DTM
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K952270 (1995). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 1 other ancestorK952270 · Dideco Adult Arterial Filters D732 Micro 20 W/20, D734 Micro 40 W/40 Micron Screen · Sorin Biomedical, Inc. · 1995199619982000200220042006
Other ancestors, by generation 1 generation back: 1 other ancestor K952270 · Dideco Adult Arterial Filters D732 Micro 20 W/20, D734 Micro 40 W/40 Micron Screen · Sorin Biomedical, Inc. · 19950
  1. Root · 1 generation backK952270 Dideco Adult Arterial Filters D732 Micro 20 W/20, D734 Micro 40 W/40…Sorin Biomedical, Inc. · 1995
  2. This deviceK052717 D732 Micro 27 PH.I.S.I.O. Adult Arterial FilterDideco S.R.L. · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K952270Dideco Adult Arterial Filters D732 Micro 20 W/20, D734 Micro 40 W/40 Micron…Sorin Biomedical, Inc.1995—
0 (this device)K052717D732 Micro 27 PH.I.S.I.O. Adult Arterial FilterDideco S.R.L.2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K052717, 1995–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTM device

  1. #1 K251744 Affinity Pixie™ Arterial Filter with Balance™…score 11.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K952270Dideco Adult Arterial Filters D732 Micro 20 W/20, D734 Micro 40 W/40 Micron Screen
Summary page 2
…ilter with 20 micron screen (hereafter referred to as D732 MICRO 20) (K952270). PREDICATE DEVICE: D736 Micro 40 Ph.I.S.I.O.: Dideco Micro…
Sorin Biomedical, Inc.1995—
*K002493Dideco Micro 40 PH.I.S.I.O (Phosphorylcholine Insert Surface in Oxgenation)…
Summary page 2
…with 40 micron screen with biocompatible treatment surface (K002493) (hereinafter referred to as the D736 MICRO Ph.I.S.1.O DEVICE DESCRIPTION: T…
Cobe Cardiovascular, Inc.2000—

Also cleared against K952270: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • 2 other devices also cite its predicate K952270.

How does its category compare?

All DTM devices

DTM Filter, Blood, Cardiopulmonary Bypass, Arterial Line: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DTM

2in 2024

2007: 32008: 12009: 52010: 22011: 12012: 22013: 12023: 12024: 22026 (partial year): 1
2007high 5 (2009) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTM

246in 2009

2007: 60 days median2009: 246 days median
2007high 246 (2009) · low 60 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTM

1in 2019

2008: 12019: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DTM

4in 2024

2007: 82008: 22010: 32011: 82012: 62013: 92014: 642015: 342016: 272017: 152018: 232019: 52020: 12021: 12022: 42024: 4
2007high 64 (2014) · low 0 (2009)2025

MAUDE reports naming product code DTM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200736008
20081—12
2009524600
20102—03
20111—08
20122—06
20131—09
20140—064
20150—034
20160—027
20170—015
20180—023
20190—15
20200—01
20210—01
20220—04
20231—00
20242—04
20250—00
20261—0—

What is it indicated for?

The Dideco D732 MICRO 27 Ph.I.S.I.O. with 27 micron screen with phosphorylcholine coating is recommended for use in the arterial line of the extracorporeal circuit during any procedure that requires cardiopulmonary bypass. The filter it is used to trap and remove gaseous emboli as well as particulate debris that maybe introduced through the arterial line. The device should not be used longer than 6 hours. Contact with blood for longer periods is not advised.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052717: D732 Micro 27 PH.I.S.I.O. Adult Arterial Filter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052717

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026