510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Model DFP-8000D/FPD Digital Radiography System with Flat Panel Detector

K052884510(k) TraditionalCleared Oct 26, 200513-day reviewClass II21 CFR 892.1650Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshiba America Medical Systems, In.C · OWB Interventional Fluoroscopic X-Ray System

Cleared on Oct 26, 2005 as substantially equivalent to K013608 (Toshiba America Medical Systems, In.C, 2001) after a 13-day review. Its family tree reaches back 2 generations to 1994. 57 later devices descend from it. It has been recalled 2 times.

Decided
Oct 26, 2005
Review
13 days
Class
Class II
Product code
OWB
Recalls
2
Predicates
1

Its longest line of descent runs back 2 generations to K941611 (1994). 57 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2008: 4 descendants cleared2010: 2 descendants cleared2011: 2 descendants cleared2018: 10 descendants cleared2012: 2 descendants cleared2015: 5 descendants cleared2016: 3 descendants cleared2014: 3 descendants cleared2019: 2 descendants cleared2013: 1 descendant cleared2020: 3 descendants cleared2021: 4 descendants cleared2025: 3 descendants cleared2022: 2 descendants cleared2023: 2 descendants cleared2024: 4 descendants cleared2017: 3 descendants cleared2026: 2 descendants clearedK941611 · TDA-4000/A4 · Toshiba America Medical Systems, In.C · 1994 · recalledK013608 · Digital Radiography System, Model DFP-8000D · Toshiba America Medical Systems, In.C · 2001 · recalled1990200020102020
Descendants, by generation 1 generation forward: 4 descendants2 generations forward: 7 descendants3 generations forward: 9 descendants4 generations forward: 9 descendants5 generations forward: 6 descendants6 generations forward: 3 descendants7 generations forward: 4 descendants8 generations forward: 5 descendants9 generations forward: 3 descendants10 generations forward: 2 descendants11 generations forward: 2 descendants12 generations forward: 2 descendants13 generations forward: 1 descendant K013608 · Digital Radiography System, Model DFP-8000D · Toshiba America Medical Systems, In.C · 2001 · recalledK941611 · TDA-4000/A4 · Toshiba America Medical Systems, In.C · 1994 · recalled0+5+10
  1. Root · 2 generations backK941611 TDA-4000/A4Toshiba America Medical Systems, In.C · 1994 · Recalled
  2. 1 generation backK013608 Digital Radiography System, Model DFP-8000DToshiba America Medical Systems, In.C · 2001 · Recalled
  3. This deviceK052884 Model DFP-8000D/FPD Digital Radiography System with Flat Panel…Toshiba America Medical Systems, In.C · 2005
  4. Descendant · cites it directly · 23 of its ownK081582 Infx-8000V, Infinix-Cfi and Infinix VfiToshiba America Medical Systems, In.C · 2008 · Recalled
  5. Descendant · 2 generations on · 21 of its ownK101868 Infinix-I Interventional Angiography System Model Infx-8000VToshiba America Medical Systems, In.C · 2010
  6. Descendant · 3 generations on · 20 of its ownK120073 Infx-8000V withToshibamedical Systems Corporation · 2012 · Recalled
  7. Descendant · cites it directly · 13 of its ownK081624 Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C · 2008 · Recalled
  8. Descendant · 2 generations on · 11 of its ownK173088 Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018

Showing 5 of 57 descendants. See all descendants

Descendants cleared per year

2008: 42010: 22011: 22012: 22013: 12014: 32015: 52016: 32017: 32018: 102019: 22020: 32021: 42022: 22023: 22024: 42025: 32026: 2
2008high 10 (2018) · low 0 (2009)2026

Most influential descendants

Showing 5 of 57 · See all
  • K081582Infx-8000V, Infinix-Cfi and Infinix VfiToshiba America Medical Systems, In.C · 2008 · cites it directly23descendants
  • K101868Infinix-I Interventional Angiography System Model Infx-8000VToshiba America Medical Systems, In.C · 2010 · 2 generations on21descendants
  • K120073Infx-8000V withToshibamedical Systems Corporation · 2012 · 3 generations on20descendants
  • K081624Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C · 2008 · cites it directly13descendants
  • K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018 · 2 generations on11descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941611TDA-4000/A4Toshiba America Medical Systems, In.C19941
−1K013608Digital Radiography System, Model DFP-8000DToshiba America Medical Systems, In.C20012
0 (this device)K052884Model DFP-8000D/FPD Digital Radiography System with Flat Panel DetectorToshiba America Medical Systems, In.C2005—
+1K081582Infx-8000V, Infinix-Cfi and Infinix VfiToshiba America Medical Systems, In.C20081
+2K101868Infinix-I Interventional Angiography System Model Infx-8000VToshiba America Medical Systems, In.C2010—
+3K120073Infx-8000V withToshibamedical Systems Corporation20123
+1K081624Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C20088
+2K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200840
201020
201120
201220
201310
201430
201550
201630
201730
2018100
201920
202030
202140
202220
202320
202440
202530
202620
FIG. 1 — Lineage of K052884, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.3 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013608Digital Radiography System, Model DFP-8000D
Summary page 1
…ICAL SYSTEMS CORPORATION 1385 Shimoishigami Otawara-shi, Tochigi 324-8550, Japan Date of Submission: October 05, 2005 Predicate Device: DFP-8000D with Image Intensifier (K013608) DEVICE DESCRIPTION This equipment is a digital radiography with Flat Panel Detector (FPD) used in diagnostic X-ray angiography s…
Toshiba America Medical Systems, In.C20012

Also cleared against K013608: 1 other device →

What descends from it? (57)

See all 57

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K081582Infx-8000V, Infinix-Cfi and Infinix VfiToshiba America Medical Systems, In.C200823
K081624Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C200813
K081621Infx-8000C (Infinix CC-I and VC-I)Toshiba America Medical Systems, In.C200810
K100102CS-Series-FPOmega Medical Imaging, Inc.20108

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 8, 2012Class IIZ-0994-2013Software designLost and incorrect images. When using the "F-Rec" fluoroscopy image acquisition recording option in the "manual mode" an infrequent software error may cause images from another study to be displayed on the monitor. The acquired images may…
Oct 1, 2007Not classifiedZ-0293-2008Software designSystem Lock-up: When performing DAS One Shot, the system may lockup due to a software timing error.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 1 company; a new generation was cleared every 7.5 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • Of its descendants, K081582 (Toshiba America Medical Systems, In.C, 2008) has gone furthest, with 23 descendants of its own.
  • 1 other device also cites its predicate K013608.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

This device is a digital radiography system used in diagnostic X-ray angiography system configuration.

This X-ray angiography system is indicated for use in diagnostic and interventional procedures for cardiac blood vessels, cerebral blood vessels, abdominal blood vessels and lower limb blood vessels.

It is intended to replace images obtained through the image intensifier technology.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K052884: Model DFP-8000D/FPD Digital Radiography System with Flat Panel Detector.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K052884

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026