510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

Infx-8000F (Infinix Csi and Infinix Dpi)

K081624510(k) TraditionalCleared Jun 23, 200813-day reviewClass II21 CFR 892.1680Recalls 8

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshiba America Medical Systems, In.C · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Jun 23, 2008 as substantially equivalent to K052412 (GE Healthcare, 2005) and 1 other predicate after a 13-day review. Its family tree reaches back 6 generations to 1989. 13 later devices descend from it. It has been recalled 8 times.

Decided
Jun 23, 2008
Review
13 days
Class
Class II
Product code
MQB
Recalls
8
Predicates
2

Its longest line of descent runs back 6 generations to K890348 (1989). 18 ancestors in all. 13 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2003: 1 other ancestor2001: 2 other ancestors1998: 1 other ancestor2002: 2 other ancestors1995: 3 other ancestors1994: 1 other ancestor1993: 1 other ancestor2018: 4 descendants cleared2020: 1 descendant cleared2021: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant cleared2024: 3 descendants cleared2025: 1 descendant cleared2026: 1 descendant clearedK890348 · LC, Cardiac Positioner #B5078A · General Electric Co. · 1989 · recalledK993037 · LCV+ Version 2 · Ge Medical Systems, Inc. · 2000 · recalledK022322 · Innova and Innova 2000 S · Ge Medical Systems, Inc. · 2002 · recalledK031637 · Innova 3100 · GE Medical Systems · 2003 · recalledK050489 · Innova 2100 · Ge Medical Systems, LLC · 2005 · recalledK052412 · Innova 2100-IQ, Innova 3100, Innova 3100-IQ, Innova 4100, and Innova 4100-IQ · GE Healthcare · 2005 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 4 other ancestors4 generations back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 1 descendant4 generations forward: 1 descendant5 generations forward: 1 descendant6 generations forward: 2 descendants7 generations forward: 2 descendants8 generations forward: 2 descendants K052412 · Innova 2100-IQ, Innova 3100, Innova 3100-IQ, Innova 4100, and Innova 4100-IQ · GE Healthcare · 2005 · recalledK050489 · Innova 2100 · Ge Medical Systems, LLC · 2005 · recalledK031637 · Innova 3100 · GE Medical Systems · 2003 · recalledK022322 · Innova and Innova 2000 S · Ge Medical Systems, Inc. · 2002 · recalledK993037 · LCV+ Version 2 · Ge Medical Systems, Inc. · 2000 · recalledK890348 · LC, Cardiac Positioner #B5078A · General Electric Co. · 1989 · recalled−50+5
  1. Root · 6 generations backK890348 LC, Cardiac Positioner #B5078AGeneral Electric Co. · 1989 · Recalled
  2. 5 generations backK993037 LCV+ Version 2Ge Medical Systems, Inc. · 2000 · Recalled
  3. 4 generations backK022322 Innova and Innova 2000 SGe Medical Systems, Inc. · 2002 · Recalled
  4. 3 generations backK031637 Innova 3100GE Medical Systems · 2003 · Recalled
  5. 2 generations backK050489 Innova 2100Ge Medical Systems, LLC · 2005 · Recalled
  6. 1 generation backK052412 Innova 2100-IQ, Innova 3100, Innova 3100-IQ, Innova 4100, and Innova…GE Healthcare · 2005 · Recalled
  7. This deviceK081624 Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C · 2008
  8. Descendant · cites it directly · 11 of its ownK173088 Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018
  9. Descendant · 2 generations on · 9 of its ownK183013 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2018
  10. Descendant · 3 generations on · 8 of its ownK192923 Vitrea Software PackageCanon Medical Systems Corporation · 2020
  11. Descendant · 4 generations on · 7 of its ownK203312 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2021
  12. Descendant · 5 generations on · 6 of its ownK213504 Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System…Canon Medical Systems Corporation · 2022

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2018: 42020: 12021: 12022: 12023: 12024: 32025: 12026: 1
2018high 4 (2018) · low 0 (2019)2026

Most influential descendants

Showing 5 of 13 · See all
  • K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018 · cites it directly11descendants
  • K183013Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2018 · 2 generations on9descendants
  • K192923Vitrea Software PackageCanon Medical Systems Corporation · 2020 · 3 generations on8descendants
  • K203312Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2021 · 4 generations on7descendants
  • K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package…Canon Medical Systems Corporation · 2022 · 5 generations on6descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K890348LC, Cardiac Positioner #B5078AGeneral Electric Co.19895
−5K993037LCV+ Version 2Ge Medical Systems, Inc.20006
−4K022322Innova and Innova 2000 SGe Medical Systems, Inc.20027
−3K031637Innova 3100GE Medical Systems200325
−2K050489Innova 2100Ge Medical Systems, LLC200527
−1K052412Innova 2100-IQ, Innova 3100, Innova 3100-IQ, Innova 4100, and Innova 4100-IQGE Healthcare200550
0 (this device)K081624Infx-8000F (Infinix Csi and Infinix Dpi)Toshiba America Medical Systems, In.C2008—
+1K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation2018—
+2K183013Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2018—
+3K192923Vitrea Software PackageCanon Medical Systems Corporation2020—
+4K203312Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2021—
+5K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software…Canon Medical Systems Corporation2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199410
199530
199810
200120
200220
200310
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201840
202010
202110
202210
202310
202430
202510
202610
FIG. 1 — Lineage of K081624, 1989–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052412Innova 2100-IQ, Innova 3100, Innova 3100-IQ, Innova 4100, and Innova 4100-IQ
Summary page 1
…[Fed. Reg. No. 892.1650, Pro. Code: 90MQB] Ik (per 21 CFR 892.1650) 21 CFR Subchapter J, Federal Diagnostic X-ray Equipment Standard GE Innova 4100; 510(k) Control # k052412 Toshiba DFP-8000D/FPD; 510(k) Control # K052884 Model Number Change These systems are single or dual plane systems that employ…
GE Healthcare200550
*K052884Model DFP-8000D/FPD Digital Radiography System with Flat Panel Detector
Summary page 1
…(per 21 CFR 892.1650) 21 CFR Subchapter J, Federal Diagnostic X-ray Equipment Standard GE Innova 4100; 510(k) Control # k052412 Toshiba DFP-8000D/FPD; 510(k) Control # K052884 Model Number Change These systems are single or dual plane systems that employ x-rays to obtain fluoroscopy or radiography imag…
Toshiba America Medical Systems, In.C20052

Also cleared against K052412: 7 other devices →

What descends from it? (13)

See all 13

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation201811
K182415Alphenix, INFX-8000F/B, V8.0Canon Medical Systems Corporation20180

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 5, 2021Class IIZ-1176-2021Software designThe x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
Dec 8, 2020Class IIZ-1271-2021Component design/selectionSystem table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose.
Mar 3, 2020Class IIZ-2327-2020Process controlBolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting.
Feb 8, 2019Class IIZ-0360-2020Error in labelingTable tilts without operator involvement as a result of liquid spilling into tilt console triggering a short circuit.
Dec 29, 2017Class IIZ-0842-2018Process controlDuring an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error.
Nov 8, 2012Class IIZ-0994-2013Software designLost and incorrect images. When using the "F-Rec" fluoroscopy image acquisition recording option in the "manual mode" an infrequent software error may cause images from another study to be displayed on the monitor. The acquired images may…
Oct 3, 2011Not classifiedZ-0331-2012Device DesignThe recall was initiated because Toshiba has confirmed that during patient transfer from a gurney to the catherization table, the tabletop may rotate unexpectedly when sufficient force is applied to the tabletop. The result of the…
Sep 29, 2008Not classifiedZ-0005-2009Software designAudible signal is not available at all times when using the HLC fluoroscopy mode. Special means of activation are not designed in for selection of High Level Controls, as required by regulation.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 6 companies; a new generation was cleared every 2.6 years on median.
  • 14 of the 18 ancestors have a recall of any class.
  • Of its descendants, K173088 (Toshibamedical Systems Corporation, 2018) has gone furthest, with 11 descendants of its own.
  • 7 other devices also cite its predicate K052412.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

This device is a digital radiography/flucroscopy system used in a diagnostic angiography configuration. This system is indicated for use in diagnostic and angicgraphic procedures for blood vessels in the heart, brain, abdomen and lower extremities.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K081624: Infx-8000F (Infinix Csi and Infinix Dpi).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K081624

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026