510(k) Report

510(k) · Cleared

Recalled · 2008

Biscem Translucent, Biscem Opaque

K060701510(k) TraditionalCleared May 15, 200660-day reviewClass II21 CFR 872.3275Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bisco, Inc. · EMA Cement, Dental

Cleared on May 15, 2006 as substantially equivalent to K032597 (Bisco, Inc., 2003) after a 60-day review. Its family tree reaches back 1 generation to 2003. 4 later devices descend from it. It has been recalled 2 times.

Decided
May 15, 2006
Review
60 days
Class
Class II
Product code
EMA
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K032597 (2003). 4 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared2018: 2 descendants cleared2026: 1 descendant clearedK032597 · Biscem GI · Bisco, Inc. · 2003200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 1 descendant K032597 · Biscem GI · Bisco, Inc. · 20030
  1. Root · 1 generation backK032597 Biscem GIBisco, Inc. · 2003
  2. This deviceK060701 Biscem Translucent, Biscem OpaqueBisco, Inc. · 2006
  3. Descendant · cites it directly · 3 of its ownK081913 Metacem, Meta P&Bond, Metacem Silane Ceramic PrimerMeta Biomed Co., Ltd. · 2008
  4. Descendant · 2 generations on · 1 of its ownK171449 MetacemMeta Biomed Co., Ltd. · 2018
  5. Descendant · 3 generations on · 0 of its ownK261166 Dia-CemDiaDent Group International · 2026
  6. Descendant · 2 generations on · 0 of its ownK180802 Meta P&BondMeta Biomed Co., Ltd. · 2018

Most influential descendants

Showing 4 of 4 · See all
  • K081913Metacem, Meta P&Bond, Metacem Silane Ceramic PrimerMeta Biomed Co., Ltd. · 2008 · cites it directly3descendants
  • K171449MetacemMeta Biomed Co., Ltd. · 2018 · 2 generations on1descendant
  • K261166Dia-CemDiaDent Group International · 2026 · 3 generations on0descendants
  • K180802Meta P&BondMeta Biomed Co., Ltd. · 2018 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K032597Biscem GIBisco, Inc.2003—
0 (this device)K060701Biscem Translucent, Biscem OpaqueBisco, Inc.2006—
+1K081913Metacem, Meta P&Bond, Metacem Silane Ceramic PrimerMeta Biomed Co., Ltd.2008—
+2K171449MetacemMeta Biomed Co., Ltd.2018—
+3K261166Dia-CemDiaDent Group International2026—
+2K180802Meta P&BondMeta Biomed Co., Ltd.2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
201820
202610
FIG. 1 — Lineage of K060701, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EMA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EMA device

  1. #1 K254109 G-Cem Universalscore 15.0 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032597Biscem GI
Summary page 1
…dental cement designed to be used as a luting cement. Its physical properties and uses are similar to the predicate device. Predicate Devices: BisCemi GI cleared under (K032597) dated November 4, 2003. Significant Performance Characteristics: BisCem GI…
Bisco, Inc.2003—

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K081913Metacem, Meta P&Bond, Metacem Silane Ceramic PrimerMeta Biomed Co., Ltd.20083

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 28, 2008Not classifiedZ-1696-2008Incorrect or no expiration dateDuring product stability testing, Bisco determined that after 15 months of storage, BISCEM Self-Adhesive Luting Cement used in self-cure mode only without light-curing may take longer than specified to set, resulting in reduced bond…
Apr 28, 2008Not classifiedZ-1697-2008Incorrect or no expiration dateDuring product stability testing, Bisco determined that after 15 months of storage, BISCEM Self-Adhesive Luting Cement used in self-cure mode only without light-curing may take longer than specified to set, resulting in reduced bond…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K081913 (Meta Biomed Co., Ltd., 2008) has gone furthest, with 3 descendants of its own.

How does its category compare?

All EMA devices

EMA Cement, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EMA

10in 2025

2007: 62008: 132009: 102010: 142011: 82012: 102013: 122014: 42015: 92016: 102017: 32018: 32019: 72020: 82021: 42022: 72023: 22024: 32025: 102026 (partial year): 7
2007high 14 (2010) · low 2 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EMA

106in 2025

2007: 48 days median2008: 71 days median2009: 86 days median2010: 86 days median2011: 79 days median2012: 128 days median2013: 178 days median2014: 174 days median2015: 134 days median2016: 182 days median2017: 141 days median2018: 237 days median2019: 127 days median2020: 164 days median2021: 184 days median2022: 245 days median2024: 59 days median2025: 106 days median2026 (partial year): 150 days median
2007high 245 (2022) · low 48 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EMA

1in 2023

2008: 22009: 12010: 12011: 52023: 1
2007high 5 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EMA

9in 2025

2007: 332008: 502009: 902010: 1062011: 2242012: 2492013: 3852014: 2072015: 852016: 162017: 132018: 42019: 122020: 52021: 82022: 32023: 62024: 52025: 9
2007high 385 (2013) · low 3 (2022)2025

MAUDE reports naming product code EMA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007648033
20081371250
20091086190
201014861106
20118795224
2012101280249
2013121780385
201441740207
20159134085
201610182016
20173141013
2018323704
20197127012
2020816405
2021418408
2022724503
20232—16
202435905
20251010609
202671500—

What is it indicated for?

1. Luting metal crowns, bridges, inlay, and onlays including porcelain-fused-to-metal and composite-to-metal varieties;

2. Luting resin crowns, bridges, inlays, onlays and veneers;

3. Luting metal or non-metal/fiber posts;

4. Luting orthodontic appliances;

5. Luting porcelain inlays, onlays, crowns, and veneers (includes alumina and zirconia).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K060701: Biscem Translucent, Biscem Opaque.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K060701

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026