510(k) Report

510(k) · Cleared

Recalled · Class II · 2020

Jetstream Workspace

K061029510(k) TraditionalCleared May 1, 200617-day reviewClass II21 CFR 892.2050Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Adac Laboratories · LLZ System, Image Processing, Radiological

Cleared on May 1, 2006 as substantially equivalent to K993946 (Adac Laboratories, 2000) and 1 other predicate after a 17-day review. Its family tree reaches back 2 generations to 1989. 26 later devices descend from it. It has been recalled once.

Decided
May 1, 2006
Review
17 days
Class
Class II
Product code
LLZ
Recalls
1
Predicates
2

Its longest line of descent runs back 2 generations to K892358 (1989). 3 ancestors in all. 26 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2008: 1 descendant cleared2007: 1 descendant cleared2016: 4 descendants cleared2011: 4 descendants cleared2020: 2 descendants cleared2015: 1 descendant cleared2018: 3 descendants cleared2021: 2 descendants cleared2026: 2 descendants cleared2024: 1 descendant cleared2025: 3 descendants cleared2019: 1 descendant cleared2023: 1 descendant clearedK892358 · Pegasys Nuclear Medicine Imaging Computer · Adac Laboratories · 1989K993946 · Pegasys Ultra · Adac Laboratories · 20001990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 5 descendants3 generations forward: 4 descendants4 generations forward: 5 descendants5 generations forward: 5 descendants6 generations forward: 2 descendants7 generations forward: 1 descendant8 generations forward: 1 descendant K993946 · Pegasys Ultra · Adac Laboratories · 2000K892358 · Pegasys Nuclear Medicine Imaging Computer · Adac Laboratories · 19890+5
  1. Root · 2 generations backK892358 Pegasys Nuclear Medicine Imaging ComputerAdac Laboratories · 1989
  2. 1 generation backK993946 Pegasys UltraAdac Laboratories · 2000
  3. This deviceK061029 Jetstream WorkspaceAdac Laboratories · 2006
  4. Descendant · cites it directly · 12 of its ownK080961 NM Application SuitePhilips Nuclear Medicine, Inc. · 2008 · Recalled
  5. Descendant · cites it directly · 10 of its ownK072468 Modification to D-Spect Cardiac Scanner SystemSpectrum Dynamics, Ltd. · 2007 · Recalled
  6. Descendant · 2 generations on · 9 of its ownK110507 Cardiac Scanner and Processing SystemSpectrum Dynamics (Israel), Ltd. · 2011
  7. Descendant · 2 generations on · 9 of its ownK111336 EBW NM 2.0Philips Medical Systems (Cleveland), Inc. · 2011
  8. Descendant · 3 generations on · 5 of its ownK162955 Multi-Modality Tumor Tracking (MMTT) applicationPhilips Medical Systems Nederland B.V. · 2016

Showing 5 of 26 descendants. See all descendants

Descendants cleared per year

2007: 12008: 12011: 42015: 12016: 42018: 32019: 12020: 22021: 22023: 12024: 12025: 32026: 2
2007high 4 (2011) · low 0 (2009)2026

Most influential descendants

Showing 5 of 26 · See all
  • K080961NM Application SuitePhilips Nuclear Medicine, Inc. · 2008 · cites it directly12descendants
  • K072468Modification to D-Spect Cardiac Scanner SystemSpectrum Dynamics, Ltd. · 2007 · cites it directly10descendants
  • K110507Cardiac Scanner and Processing SystemSpectrum Dynamics (Israel), Ltd. · 2011 · 2 generations on9descendants
  • K111336EBW NM 2.0Philips Medical Systems (Cleveland), Inc. · 2011 · 2 generations on9descendants
  • K162955Multi-Modality Tumor Tracking (MMTT) applicationPhilips Medical Systems Nederland B.V. · 2016 · 3 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K892358Pegasys Nuclear Medicine Imaging ComputerAdac Laboratories1989—
−1K993946Pegasys UltraAdac Laboratories2000—
0 (this device)K061029Jetstream WorkspaceAdac Laboratories2006—
+1K080961NM Application SuitePhilips Nuclear Medicine, Inc.20081
+1K072468Modification to D-Spect Cardiac Scanner SystemSpectrum Dynamics, Ltd.20071
+2K110507Cardiac Scanner and Processing SystemSpectrum Dynamics (Israel), Ltd.2011—
+2K111336EBW NM 2.0Philips Medical Systems (Cleveland), Inc.2011—
+3K162955Multi-Modality Tumor Tracking (MMTT) applicationPhilips Medical Systems Nederland B.V.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
200810
201140
201510
201640
201830
201910
202020
202120
202310
202410
202530
202620
FIG. 1 — Lineage of K061029, 1989–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993946Pegasys Ultra
Summary page 1
…vice(s): Manufacturer Product Name 510(k) No. ADAC Laboratories Pegasys UltraTM K993946 ADAC Laboratories Predicate JETStream® Workspace K042880 D. Device Description: JETS…
Adac Laboratories2000—
*K042880Jetstream Workspace
Summary page 1
…510(k) No. ADAC Laboratories Pegasys UltraTM K993946 ADAC Laboratories Predicate JETStream® Workspace K042880 D. Device Description: JETStreamCR) Workspace is a Windows®-based Nuclear Medicine workstation for the…
Adac Laboratories20041

Also cleared against K993946: 4 other devices →

What descends from it? (26)

See all 26

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080961NM Application SuitePhilips Nuclear Medicine, Inc.200812
K072468Modification to D-Spect Cardiac Scanner SystemSpectrum Dynamics, Ltd.200710
K152503ImagenSPECTCardiovascular Imaging Technologies20161

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 19, 2020Class IIZ-0852-2021Device DesignA software defect that has the potential to result in image misdiagnosis and incorrect treatment of a patient.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 1 company; a new generation was cleared every 10.5 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K080961 (Philips Nuclear Medicine, Inc., 2008) has gone furthest, with 12 descendants of its own.
  • 4 other devices also cite its predicate K993946.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

JETStream® Workspace is a nuclear medicine image display and processing workstation that provides software applications used to process, analyze, and display medical images/data. The results obtained may be used as a tool, by a nuclear physician, in determining the diagnosis of patient disease conditions in various organs, tissues, and other anatomical structures. The data processed may be derived from any nuclear medicine gamma camera. The JETStream® Workspace system should only be operated by qualified healthcare professionals trained in the use of nuclear medicine equipment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061029: Jetstream Workspace.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K061029

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026