510(k) Report

510(k) · Cleared

Cleared

Lorenz Biotech Aptiva, Version 2.13

K061828510(k) TraditionalCleared Aug 24, 2007422-day reviewClass II21 CFR 882.5890

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lorenz Biotech S.P.A. · GZJ Stimulator, Nerve, Transcutaneous, For Pain Relief

Cleared on Aug 24, 2007 as substantially equivalent to K021755 (Apex Medical Corp., 2002) and 8 other predicates after a 422-day review. Its family tree reaches back 2 generations to 1989.

Decided
Aug 24, 2007
Review
422 days
Class
Class II
Product code
GZJ
Recalls
None
Predicates
9

Its longest line of descent runs back 2 generations to K892649 (1989). 22 ancestors in all, the oldest K843924 (1985). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2003: 1 other ancestor2002: 2 other ancestors2001: 3 other ancestors1998: 2 other ancestors1997: 2 other ancestors1999: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestors1993: 2 other ancestors1992: 1 other ancestor1991: 1 other ancestor1987: 1 other ancestor1985: 1 other ancestorK892649 · Verimed Myoexorciser Iii (Myo Iii) · Verimed Holdings, Inc. · 1989K972487 · Emg Retrainer · Chattanooga Group, Inc. · 199719851990199520002005
Other ancestors, by generation 1 generation back: 8 other ancestors2 generations back: 12 other ancestors K972487 · Emg Retrainer · Chattanooga Group, Inc. · 1997K892649 · Verimed Myoexorciser Iii (Myo Iii) · Verimed Holdings, Inc. · 19890
  1. Root · 2 generations backK892649 Verimed Myoexorciser Iii (Myo Iii)Verimed Holdings, Inc. · 1989
  2. 1 generation backK972487 Emg RetrainerChattanooga Group, Inc. · 1997
  3. This deviceK061828 Lorenz Biotech Aptiva, Version 2.13Lorenz Biotech S.P.A. · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K892649Verimed Myoexorciser Iii (Myo Iii)Verimed Holdings, Inc.1989—
−1K972487Emg RetrainerChattanooga Group, Inc.1997—
0 (this device)K061828Lorenz Biotech Aptiva, Version 2.13Lorenz Biotech S.P.A.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198710
199110
199210
199320
199420
199510
199720
199820
199910
200130
200220
200310
FIG. 1 — Lineage of K061828, 1989–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GZJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZJ device

  1. #1 K252767 actiTENS miniscore 13.1 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (9)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021755Apex Medical Digital Tens TS1211, TS1212
Summary page 1
…EDICATE DEVICES Functionality Predicate Device TENS * Apex Medical Digital TENS (K021755) * GEMS-HV TENS (K032994) * Bioscope…
Apex Medical Corp.2002—
*K032994GM3 Series HV Tens, Model GM3X3HV (Where X IS Parameter of Different Housing)
Summary page 1
…Predicate Device TENS * Apex Medical Digital TENS (K021755) * GEMS-HV TENS (K032994) * Bioscope SD TENS (K970249) * Proma…
Gemore Technology Co, Ltd.2003—
*K970429Bioscope SD Tens, Arista SD Plus, AP-102080T
Our reading of the summary gave K970249, FDA’s number for Simplex Airbrator (Simplex Medical Systems, Inc.). Corrected to the number with two digits swapped whose FDA name carries the summary’s words for the device, “Bioscope SD TENS”.
Apex Medical Corp.1997—
*K022405Modification to Promax-XP, Tens and Microcurrent Device; Promax-Tens, Tens Device…
Summary page 1
…* GEMS-HV TENS (K032994) * Bioscope SD TENS (K970249) * Promax TENS (K022405) * NeuroTrain III (K003433) Electromyography (EMG)/Biofeedback a EMG Ret…
Rehabilicare, Inc.2002—
*K003433Neuro-Train Iii (3)
Summary page 1
…* Bioscope SD TENS (K970249) * Promax TENS (K022405) * NeuroTrain III (K003433) Electromyography (EMG)/Biofeedback a EMG Retrainer Dual Channel (K972487)…
Sterne Equipment Co., Ltd.2001—
*K972487Emg Retrainer
Summary page 1
…romax TENS (K022405) * NeuroTrain III (K003433) Electromyography (EMG)/Biofeedback a EMG Retrainer Dual Channel (K972487) a MES-9000/EMG System (K013399) a Sy…
Chattanooga Group, Inc.1997—
*K013399Model Mes-9000/Emg System
Summary page 1
…n III (K003433) Electromyography (EMG)/Biofeedback a EMG Retrainer Dual Channel (K972487) a MES-9000/EMG System (K013399) a Synergy System (K981405) Nerve conduction velocity (ENG) Brevio (K0…
Myotronics-Noromed, Inc.2001—
*K981405Synergy LT
Summary page 1
…iner Dual Channel (K972487) a MES-9000/EMG System (K013399) a Synergy System (K981405) Nerve conduction velocity (ENG) Brevio (K010269) Lorenz Biotech, S.p.A. August 6, 2007…
Oxford Instruments, Plc.1998—
*K012069Modification to:Brevio Nerve Conduction Test Instrument
Our reading of the summary gave K010269, which is not a number in FDA’s lists. Corrected to the number with two digits swapped whose FDA name carries the summary’s words for the device, “Brevio”.
Neurotron Medical, Inc.2001—

Also cleared against K021755: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 9.9 years on median.
  • None of the 22 ancestors has a recall.
  • 5 other devices also cite its predicate K021755.

How does its category compare?

All GZJ devices

GZJ Stimulator, Nerve, Transcutaneous, For Pain Relief: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GZJ

1in 2025

2007: 132008: 112009: 162010: 52011: 52012: 122013: 22014: 42015: 32016: 32017: 32018: 22019: 32020: 42021: 32022: 42023: 12024: 32025: 12026 (partial year): 2
2007high 16 (2009) · low 1 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZJ

207in 2024

2007: 223 days median2008: 136 days median2009: 155 days median2010: 232 days median2011: 168 days median2012: 154 days median2014: 344 days median2015: 202 days median2016: 163 days median2017: 113 days median2019: 156 days median2020: 183 days median2021: 231 days median2022: 175 days median2024: 207 days median
2007high 344 (2014) · low 113 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZJ

1in 2011

2007: 42008: 12011: 1
2007high 4 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GZJ

13in 2025

2007: 42008: 452009: 172010: 222011: 222012: 202013: 102014: 232015: 182016: 322017: 582018: 212019: 72020: 102021: 52022: 42023: 392024: 122025: 13
2007high 58 (2017) · low 4 (2007)2025

MAUDE reports naming product code GZJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071322344
200811136145
200916155017
20105232022
20115168122
201212154020
20132—010
20144344023
20153202018
20163163032
20173113058
20182—021
2019315607
20204183010
2021323105
2022417504
20231—039
20243207012
20251—013
20262—0—

What is it indicated for?

The Aptiva TM v2.13U is a multifunctional transcutaneous electrical nerve stimulator

(TENS) equipped with a surface electromyography and electroneurography.

Aptiva TM is indicated for symptomatic relief and management of chronic pain, intractable

pain and/or as an adjunctive treatment for the management of post-traumatic pain.

The dynamic surface electromyography and electroneurography system is used for

biofeedback, relaxation training, and muscle re-education as well as monitoring and

display of bioelectric signals produced by muscles, stimulate peripheral nerves, and

monitor and display the electrical activity produced by nerves.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061828: Lorenz Biotech Aptiva, Version 2.13.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K061828

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026