510(k) Report

510(k) · Cleared

Cleared

Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210

K062079510(k) TraditionalCleared Oct 19, 200690-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corporation · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Oct 19, 2006 as substantially equivalent to K030974 (Baxter Healthcare Corp, 2003) and 1 other predicate after a 90-day review. Its family tree reaches back 6 generations to 2001. 26 later devices descend from it.

Decided
Oct 19, 2006
Review
90 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K001283 (2001). 14 ancestors in all, the oldest K872364 (1987). 26 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor1998: 2 other ancestors1994: 1 other ancestor1989: 1 other ancestor1987: 1 other ancestor1997: 1 other ancestor1991: 1 other ancestor2008: 1 descendant cleared2009: 1 descendant cleared2013: 6 descendants cleared2016: 1 descendant cleared2014: 2 descendants cleared2010: 1 descendant cleared2015: 1 descendant cleared2017: 2 descendants cleared2026: 3 descendants cleared2020: 3 descendants cleared2023: 1 descendant cleared2025: 3 descendants cleared2024: 1 descendant clearedK001283 · Lifemate Hemofiltration System · Nxstage Medical, Inc. · 2001K012510 · Modification to: Lifemate Hemofiltration System · Nxstage Medical, Inc. · 2001K020858 · Nxstage Therapy System · Nxstage Medical, Inc. · 2002K030470 · Nxstage System One · Nxstage Medical, Inc. · 2003K041424 · Nxstage System One · Nxstage Medical, Inc. · 2004K050525 · Nxstage System One · Nxstage Medical, Inc. · 2005 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors4 generations back: 2 other ancestors5 generations back: 2 other ancestors 1 generation forward: 6 descendants2 generations forward: 4 descendants3 generations forward: 3 descendants4 generations forward: 5 descendants5 generations forward: 3 descendants6 generations forward: 3 descendants7 generations forward: 2 descendants K050525 · Nxstage System One · Nxstage Medical, Inc. · 2005 · recalledK041424 · Nxstage System One · Nxstage Medical, Inc. · 2004K030470 · Nxstage System One · Nxstage Medical, Inc. · 2003K020858 · Nxstage Therapy System · Nxstage Medical, Inc. · 2002K012510 · Modification to: Lifemate Hemofiltration System · Nxstage Medical, Inc. · 2001K001283 · Lifemate Hemofiltration System · Nxstage Medical, Inc. · 2001−50+5
  1. Root · 6 generations backK001283 Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  2. 5 generations backK012510 Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  3. 4 generations backK020858 Nxstage Therapy SystemNxstage Medical, Inc. · 2002
  4. 3 generations backK030470 Nxstage System OneNxstage Medical, Inc. · 2003
  5. 2 generations backK041424 Nxstage System OneNxstage Medical, Inc. · 2004
  6. 1 generation backK050525 Nxstage System OneNxstage Medical, Inc. · 2005 · Recalled
  7. This deviceK062079 Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2006
  8. Descendant · cites it directly · 20 of its ownK083778 Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2009
  9. Descendant · cites it directly · 16 of its ownK082414 Optiflux F250NR, Model 0500325EFresenius Medical Care North America · 2008 · Recalled
  10. Descendant · 2 generations on · 13 of its ownK123262 Optiflux Ultra DialyzerFresenius Medical Care North America · 2014
  11. Descendant · 3 generations on · 12 of its ownK152367 Optiflux dialyzerFresenius Medical Care North America · 2015 · Recalled
  12. Descendant · 4 generations on · 9 of its ownK162488 Optiflux dialyzerFresenius Medical Care North America · 2017 · Recalled

Showing 5 of 26 descendants. See all descendants

Descendants cleared per year

2008: 12009: 12010: 12013: 62014: 22015: 12016: 12017: 22020: 32023: 12024: 12025: 32026: 3
2008high 6 (2013) · low 0 (2011)2026

Most influential descendants

Showing 5 of 26 · See all
  • K083778Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2009 · cites it directly20descendants
  • K082414Optiflux F250NR, Model 0500325EFresenius Medical Care North America · 2008 · cites it directly16descendants
  • K123262Optiflux Ultra DialyzerFresenius Medical Care North America · 2014 · 2 generations on13descendants
  • K152367Optiflux dialyzerFresenius Medical Care North America · 2015 · 3 generations on12descendants
  • K162488Optiflux dialyzerFresenius Medical Care North America · 2017 · 4 generations on9descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K001283Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−5K012510Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−4K020858Nxstage Therapy SystemNxstage Medical, Inc.2002—
−3K030470Nxstage System OneNxstage Medical, Inc.2003—
−2K041424Nxstage System OneNxstage Medical, Inc.2004—
−1K050525Nxstage System OneNxstage Medical, Inc.20052
0 (this device)K062079Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation2006—
+1K083778Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation2009—
+1K082414Optiflux F250NR, Model 0500325EFresenius Medical Care North America20083
+2K123262Optiflux Ultra DialyzerFresenius Medical Care North America2014—
+3K152367Optiflux dialyzerFresenius Medical Care North America20151
+4K162488Optiflux dialyzerFresenius Medical Care North America20174

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199110
199410
199710
199820
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
200910
201010
201360
201420
201510
201610
201720
202030
202310
202410
202530
202630
FIG. 1 — Lineage of K062079, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030974Exeltra High Flux Dialyzer, Models 150 & 170
Summary page 1
…Common Name: Dialyzer Classification Name: High Permeability Hemodialysis System Predicate Devices: Baxter's Exeltra dialyzer, K030974 NxStage Medical's NxStage System One, K050525 Device Description: Xenium dialyzers are polye…
Baxter Healthcare Corp2003—
*K050525Nxstage System One
Summary page 1
…: High Permeability Hemodialysis System Predicate Devices: Baxter's Exeltra dialyzer, K030974 NxStage Medical's NxStage System One, K050525 Device Description: Xenium dialyzers are polyethersulfone fiber dialyzers and will be labele…
Nxstage Medical, Inc.20052

Also cleared against K030974: 1 other device →

What descends from it? (26)

See all 26

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K083778Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation200920
K082414Optiflux F250NR, Model 0500325EFresenius Medical Care North America200816
K160558Rapido Hollow-Fibre DialyzersBellco Srl20160
K131050Nxstage 1.6M2 DialyzerNxstage Medical, Inc.20130
K122952Nipro Pureflux-L HemodialyzerNipro Medical Corporation20130
K122343Pureflux-H HemodialyzerNipro Medical Corporation20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 12 months on median.
  • 2 of the 14 ancestors have a recall of any class.
  • Of its descendants, K083778 (Baxter Healthcare Corporation, 2009) has gone furthest, with 20 descendants of its own.
  • 1 other device also cites its predicate K030974.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

Hemodialysis with Xenium dialyzers is indicated for patients with acute or chronic renal failure when conservative therapy is judged to be inadequate. It also may be indicated in the treatment of patients intoxicated with poisons or drugs.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062079: Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062079

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026