510(k) Report

510(k) · Cleared

Cleared

Pureflux-H Hemodialyzer

K122343510(k) TraditionalCleared May 7, 2013277-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nipro Medical Corporation · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on May 7, 2013 as substantially equivalent to K062079 (Baxter Healthcare Corporation, 2006) after a 277-day review. Its family tree reaches back 7 generations to 2001.

Decided
May 7, 2013
Review
277 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K001283 (2001). 15 ancestors in all, the oldest K872364 (1987). No later device cites it as a predicate yet.

  1. Root · 7 generations backK001283 Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  2. 6 generations backK012510 Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  3. 5 generations backK020858 Nxstage Therapy SystemNxstage Medical, Inc. · 2002
  4. 4 generations backK030470 Nxstage System OneNxstage Medical, Inc. · 2003
  5. 3 generations backK041424 Nxstage System OneNxstage Medical, Inc. · 2004
  6. 2 generations backK050525 Nxstage System OneNxstage Medical, Inc. · 2005 · Recalled
  7. 1 generation backK062079 Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2006
  8. This deviceK122343 Pureflux-H HemodialyzerNipro Medical Corporation · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K001283Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−6K012510Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−5K020858Nxstage Therapy SystemNxstage Medical, Inc.2002—
−4K030470Nxstage System OneNxstage Medical, Inc.2003—
−3K041424Nxstage System OneNxstage Medical, Inc.2004—
−2K050525Nxstage System OneNxstage Medical, Inc.20052
−1K062079Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation2006—
0 (this device)K122343Pureflux-H HemodialyzerNipro Medical Corporation2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199110
199410
199710
199820
200310
FIG. 1 — Lineage of K122343, 2001–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K062079Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210
Summary page 1
…n High permeability bemodialysis system Name per 2I1CFR 876.5860 Common Name Hemodiallyzer Substantial Equivalence K062079 Baxter Xcnium Hemodialyzer Device Description The PUREFLUX-H hemodialyzer is a medical device…
Baxter Healthcare Corporation2006—

Also cleared against K062079: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 12 months on median.
  • 2 of the 15 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K062079.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

Hemodinlysis with a PUREFLLJX-H hemodialyzer is indicated for patients with acute or chronic renal failure when conservative therapy is judged to be inadequate. It also may be indicated in the treatment of patients intoxicated with poisons or drugs.

The device is for prescription use only.

This product is intended for single use only. The performance properties of reused dialyzers have not been established.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122343: Pureflux-H Hemodialyzer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122343

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026