510(k) Report

510(k) · Cleared

Cleared

Phase 3, Model DT-1

K062099510(k) TraditionalCleared Jan 25, 2007185-day reviewClass II21 CFR 870.5325

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Datrend Systems, Inc. · DRL Tester, Defibrillator

Cleared on Jan 25, 2007 as substantially equivalent to K941404 (Hogan & Hartson, 1994) after a 185-day review. Its family tree reaches back 1 generation to 1994.

Decided
Jan 25, 2007
Review
185 days
Class
Class II
Product code
DRL
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K941404 (1994). No later device cites it as a predicate yet.

K941404 · Impulse 4000 Defibrillator/Transcutaneous Pacer Analyzer · Hogan & Hartson · 19941990199520002005
  1. Root · 1 generation backK941404 Impulse 4000 Defibrillator/Transcutaneous Pacer AnalyzerHogan & Hartson · 1994
  2. This deviceK062099 Phase 3, Model DT-1Datrend Systems, Inc. · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K941404Impulse 4000 Defibrillator/Transcutaneous Pacer AnalyzerHogan & Hartson1994—
0 (this device)K062099Phase 3, Model DT-1Datrend Systems, Inc.2007—
FIG. 1 — Lineage of K062099, 1994–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K941404Impulse 4000 Defibrillator/Transcutaneous Pacer AnalyzerHogan & Hartson1994—

Also cleared against K941404: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K941404.

How does its category compare?

All DRL devices

DRL Tester, Defibrillator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · DRL

1in 2019

2007: 12008: 22011: 12015: 12018: 12019: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRL

Too few DRL 510(k)s in any year since 2007 to give a median.

Recalls per year · DRL

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRL

2in 2013

2009: 12013: 2
2007high 2 (2013) · low 0 (2007)2025

MAUDE reports naming product code DRL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—00
20090—01
20100—00
20111—00
20120—00
20130—02
20140—00
20151—10
20160—00
20170—00
20181—00
20191—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

Datrend Systems Inc. Phase 3 Defibrillator/PacerAnalyzeris a precision instrument for ensuring that defibrillators and defibrillators with transcutaneous pacemakers comply with performance specifications. Phase 3 is connected to the output of a defibrillator and is used to measure the energy delivered by the defibrillator into a standard resistive load. It can also provide waveform information. Phase 3's main function is to measure the energy output of a…

Read the full statement (255 words)

Datrend Systems Inc. Phase 3 Defibrillator/PacerAnalyzeris a precision instrument for ensuring

that defibrillators and defibrillators with transcutaneous pacemakers comply with performance

specifications.

Phase 3 is connected to the output of a defibrillator and is used to measure the energy delivered

by the defibrillator into a standard resistive load. It can also provide waveform information.

Phase 3's main function is to measure the energy output of a defibrillator. The instrument has a

built-in load resistance of 50 ohms, which roughly corresponds to the impedance of the human

body. The defibrillator paddles are connected to Phase 3 contact plates, or directly connected to

the energy input if using the hands-free defibrillator function. Thus, the defibrillator is connected

through the load resistance of Phase 3. When the defibrillator is discharged, Phase 3 will

calculate and display the energy delivered.

The intended end user is a trained / skilled biomedical equipment technician who is required to

perform incoming inspections, scheduled periodic maintenance, and repair servicing of

defibrillators, both stand alone and with pacing. Such end users may be associated with public,

private, or commercial institutions, including: hospitals, clinics, third-party service companies that

repair or calibrate medical equipment. In general, the end user is a technically trained individual,

at a post-secondary school level, specializing in medical instrumentation technology.

Phase 3 is intended to be used in the laboratory environment, outside of the patient care vicinity,

and is not intended to be used on patients or to test devices while connected to patients.

Phase 3 is not intended for over-the-counter use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062099: Phase 3, Model DT-1.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062099

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026