Defibrillator Analyzer - DA-2006P

K110192510(k) TraditionalCleared Feb 8, 201115-day reviewClass II21 CFR 870.5325Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bc Group International, Inc. · DRL Tester, Defibrillator

Cleared on Feb 8, 2011 as substantially equivalent to K963190 (Metron U.S., Inc., 1997) after a 15-day review. Its family tree reaches back 1 generation to 1997. 1 later device descends from it. It has been recalled once.

Decided
Feb 8, 2011
Review
15 days
Class
Class II
Product code
DRL
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K963190 (1997). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2019: 1 descendant clearedK963190 · QA-40M Defibrillator Tester · Metron U.S., Inc. · 19971995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K963190 · QA-40M Defibrillator Tester · Metron U.S., Inc. · 19970
  1. Root · 1 generation backK963190 QA-40M Defibrillator TesterMetron U.S., Inc. · 1997
  2. This deviceK110192 Defibrillator Analyzer - DA-2006PBc Group International, Inc. · 2011
  3. Descendant · cites it directly · 0 of its ownK190437 Delta 3300Netech Corporation · 2019

Most influential descendants

Showing 1 of 1 · See all
  • K190437Delta 3300Netech Corporation · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K963190QA-40M Defibrillator TesterMetron U.S., Inc.1997—
0 (this device)K110192Defibrillator Analyzer - DA-2006PBc Group International, Inc.2011—
+1K190437Delta 3300Netech Corporation2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K110192, 1997–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K963190QA-40M Defibrillator Tester
Summary page 1
…Class Class 11/21CFR 870.5325 Product Code DRL Predicate Devices *Metron QA-40/45M Defibrillator Tester (K(963190) 5.1 BC Group International, Inc. Section 514 Compliance…
Metron U.S., Inc.1997—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K190437Delta 3300Netech Corporation20190

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 28, 2015Class IIIZ-0457-2016Employee errorDevice is not functioning as intended: Two wires running to the ECG distribution circuit board are reversed resulting in inverted waveforms.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K190437 (Netech Corporation, 2019) has gone furthest, with 0 descendants of its own.

How does its category compare?

All DRL devices

DRL Tester, Defibrillator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · DRL

1in 2019

2007: 12008: 22011: 12015: 12018: 12019: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRL

Too few DRL 510(k)s in any year since 2007 to give a median.

Recalls per year · DRL

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRL

2in 2013

2009: 12013: 2
2007high 2 (2013) · low 0 (2007)2025

MAUDE reports naming product code DRL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—00
20090—01
20100—00
20111—00
20120—00
20130—02
20140—00
20151—10
20160—00
20170—00
20181—00
20191—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The DA-2006/DA-2006P are used to determine that defibrillators and transcutaneous pacemakers are performing within their performance specifications through the measurement of energy output. The DA-2006 tests defibrillators while the DA-2006P additionally tests transcutaneous pacemakers.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110192: Defibrillator Analyzer - DA-2006P.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K110192

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026