Shimadzu Corp. · IZI System, X-Ray, Angiographic
Cleared on Oct 5, 2006 after a 52-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled 4 times.
- Decided
- Oct 5, 2006
- Review
- 52 days
- Class
- Class II
- Product code
- IZI
- Recalls
- 4
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK062360 Bransist SafireShimadzu Corp. · 2006
- Descendant · cites it directly · 0 of its ownK072006 DAR-9400FShimadzu Corp. · 2007
Most influential descendants
Showing 1 of 1 · See all- K072006DAR-9400FShimadzu Corp. · 2007 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K062360 | Bransist Safire | Shimadzu Corp. | 2006 | — |
| +1 | K072006 | DAR-9400F | Shimadzu Corp. | 2007 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2007 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IZI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IZI device
- #1 K230727 SPY Portable Handheld Imaging (SPY-PHI) Systemscore 23.2 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K072006 | DAR-9400F | 2007 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Apr 20, 2026 | Class II | Z-2294-2026 | Component design/selection | Electromagnetic contactors within high voltage generator may weld together, resulting in current being supplied to power supply even if power is off. |
| Dec 16, 2021 | Class II | Z-0654-2022 | Process change control | Due to the inadequate adjusting criteria in installation, the system generator on two Digital Angiography Systems, the irradiated x-ray may exceed the x-ray radiation dose rate in fluoroscopic mode. |
| Nov 18, 2020 | Class II | Z-0554-2021 | Software design | The firm has identified a problem with the control software for the celling arm of the X-Ray System . This software issue could cause the ceiling arm of the device to move after the operator has released the movement lever. This could… |
| Jan 14, 2019 | Class II | Z-0959-2019 | Software design | Normal operation of the device is to power up the device in the morning, register the first patient, and then perform a fluoroscopy. If, however, the user powers up the device in the morning and makes an error by starting a fluoroscopy… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K072006 (Shimadzu Corp., 2007) has gone furthest, with 0 descendants of its own.
How does its category compare?
All IZI devicesIZI System, X-Ray, Angiographic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · IZI
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IZI
81in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IZI
1in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IZI
2,171in 2025
MAUDE reports naming product code IZI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 28 | 6 | 92 |
| 2008 | 6 | 68 | 52 | 101 |
| 2009 | 2 | — | 18 | 132 |
| 2010 | 2 | — | 11 | 252 |
| 2011 | 4 | 104 | 6 | 377 |
| 2012 | 1 | — | 6 | 77 |
| 2013 | 1 | — | 6 | 58 |
| 2014 | 4 | 111 | 5 | 123 |
| 2015 | 0 | — | 14 | 36 |
| 2016 | 1 | — | 7 | 102 |
| 2017 | 2 | — | 1 | 88 |
| 2018 | 2 | — | 2 | 49 |
| 2019 | 2 | — | 2 | 30 |
| 2020 | 1 | — | 2 | 14 |
| 2021 | 1 | — | 1 | 29 |
| 2022 | 1 | — | 0 | 265 |
| 2023 | 3 | 81 | 0 | 1,204 |
| 2024 | 2 | — | 0 | 1,332 |
| 2025 | 2 | — | 0 | 2,171 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
This device is an angiographic X-ray system, as described in 21 CFR 892.1600. This system is intended to be used for radiologic visualization of the heart, blood vessels or lymphatic system during or after injection of a contrast medium. It is to be used in the diagnosis of the circulatory vascular system while being combined with a positioning device and other devices.
This device is operated and used by physicians and X-ray Technologists.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K062360 · printed Nov 6, 2026
Cite this page
510(k) Report. “K062360: Bransist Safire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062360
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026