Pressio Icp Monitoring System

K062584510(k) TraditionalCleared Jul 5, 2007307-day reviewClass II21 CFR 882.1620Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sophysa SA · GWM Device, Monitoring, Intracranial Pressure

Cleared on Jul 5, 2007 as substantially equivalent to K945585 (Johnson & Johnson Professionals, Inc., 1995) and 3 other predicates after a 307-day review. Its family tree reaches back 1 generation to 1994. 8 later devices descend from it. It has been recalled 2 times.

Decided
Jul 5, 2007
Review
307 days
Class
Class II
Product code
GWM
Recalls
2
Predicates
4

Its longest line of descent runs back 1 generation to K914479 (1994). 4 ancestors in all. 8 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1999: 1 other ancestor1998: 1 other ancestor1995: 1 other ancestor2011: 2 descendants cleared2017: 2 descendants cleared2025: 1 descendant cleared2013: 1 descendant cleared2012: 1 descendant cleared2026: 1 descendant clearedK914479 · Microsensor Intracranial Pressure Transducer · Codman & Shurtleff, Inc. · 1994 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors 1 generation forward: 3 descendants2 generations forward: 4 descendants3 generations forward: 1 descendant K914479 · Microsensor Intracranial Pressure Transducer · Codman & Shurtleff, Inc. · 1994 · recalled0
  1. Root · 1 generation backK914479 Microsensor Intracranial Pressure TransducerCodman & Shurtleff, Inc. · 1994 · Recalled
  2. This deviceK062584 Pressio Icp Monitoring SystemSophysa SA · 2007
  3. Descendant · cites it directly · 7 of its ownK103206 Raumedic- Icp-Monitoring SystemRaumedic AG · 2011
  4. Descendant · cites it directly · 6 of its ownK112017 Raumedic Icp Monitoring SystemRaumedic AG · 2011
  5. Descendant · 2 generations on · 5 of its ownK120252 Raumedic-Icp-Temp-Monitoring-SystemRaumedic AG · 2012
  6. Descendant · 2 generations on · 4 of its ownK130529 Raumedic-Pto-Monitoring-SystemRaumedic AG · 2013
  7. Descendant · cites it directly · 1 of its ownK162108 Pressio 2 ICP Monitoring SystemSophysa SA · 2017 · Recalled

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2011: 22012: 12013: 12017: 22025: 12026: 1
2011high 2 (2011) · low 0 (2014)2026

Most influential descendants

Showing 5 of 8 · See all
  • K103206Raumedic- Icp-Monitoring SystemRaumedic AG · 2011 · cites it directly7descendants
  • K112017Raumedic Icp Monitoring SystemRaumedic AG · 2011 · cites it directly6descendants
  • K120252Raumedic-Icp-Temp-Monitoring-SystemRaumedic AG · 2012 · 2 generations on5descendants
  • K130529Raumedic-Pto-Monitoring-SystemRaumedic AG · 2013 · 2 generations on4descendants
  • K162108Pressio 2 ICP Monitoring SystemSophysa SA · 2017 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K914479Microsensor Intracranial Pressure TransducerCodman & Shurtleff, Inc.19943
0 (this device)K062584Pressio Icp Monitoring SystemSophysa SA2007—
+1K103206Raumedic- Icp-Monitoring SystemRaumedic AG2011—
+1K112017Raumedic Icp Monitoring SystemRaumedic AG2011—
+2K120252Raumedic-Icp-Temp-Monitoring-SystemRaumedic AG2012—
+2K130529Raumedic-Pto-Monitoring-SystemRaumedic AG2013—
+1K162108Pressio 2 ICP Monitoring SystemSophysa SA20173

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199810
199910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201120
201210
201310
201720
202510
202610
FIG. 1 — Lineage of K062584, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWM device

  1. #1 K252241 Pressio 3 Multi-parameter Neuromonitoring Systemscore 13.0 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K945585Coman (R) CU-11 Model Number 82-6634
Summary page 3
…ge 53 3.7 Substantial Equivalence Summary The Pressio® ICP monitoring system is substantially equivalent to the Codman® ICP express monitoring system (K945585, K914479, K991222 and K974088) in terms of intended use, materials, design, function and operating characteristics. The two monit…
Johnson & Johnson Professionals, Inc.1995—
*K914479Microsensor Intracranial Pressure Transducer
Summary page 3
…= Page 3 === 3.7 Substantial Equivalence Summary The Pressio® ICP monitoring system is substantially equivalent to the Codman® ICP express monitoring system (K945585, K914479, K991222 and K974088) in terms of intended use, materials, design, function and operating characteristics. The two monitoring sys…
Codman & Shurtleff, Inc.19943
*K991222Codman Microsensor Ventricular Catheter Kit
Summary page 3
…=== 3.7 Substantial Equivalence Summary The Pressio® ICP monitoring system is substantially equivalent to the Codman® ICP express monitoring system (K945585, K914479, K991222 and K974088) in terms of intended use, materials, design, function and operating characteristics. The two monitoring systems util…
Johnson & Johnson Professionals, Inc.1999—
*K974088Codman Intracranial Bolt
Summary page 3
…ubstantial Equivalence Summary The Pressio® ICP monitoring system is substantially equivalent to the Codman® ICP express monitoring system (K945585, K914479, K991222 and K974088) in terms of intended use, materials, design, function and operating characteristics. The two monitoring systems utilize the same…
Johnson & Johnson Professionals, Inc.19981

Also cleared against K945585: 1 other device →

What descends from it? (8)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K103206Raumedic- Icp-Monitoring SystemRaumedic AG20117
K112017Raumedic Icp Monitoring SystemRaumedic AG20116
K162108Pressio 2 ICP Monitoring SystemSophysa SA20171

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 9, 2024Class IIZ-1825-2024Process change controlAn increase in claims related to leakage of cerebrospinal fluid (CSF) from the proximal end of the catheter. In the event of a leak going undetected during implantation, it could pose an infectious risk to the patient. The cause of the…
Apr 9, 2024Class IIZ-1826-2024Process change controlAn increase in claims related to leakage of cerebrospinal fluid (CSF) from the proximal end of the catheter. In the event of a leak going undetected during implantation, it could pose an infectious risk to the patient. The cause of the…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 2 of the 4 ancestors have a recall of any class.
  • Of its descendants, K103206 (Raumedic AG, 2011) has gone furthest, with 7 descendants of its own.
  • 1 other device also cites its predicate K945585.

How does its category compare?

All GWM devices

GWM Device, Monitoring, Intracranial Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GWM

1in 2025

2007: 22008: 22009: 12010: 22011: 32012: 42013: 22014: 22016: 32017: 32018: 12019: 22020: 32021: 22024: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWM

30in 2020

2011: 123 days median2012: 100 days median2016: 192 days median2017: 37 days median2020: 30 days median
2007high 192 (2016) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWM

3in 2025

2008: 12010: 92011: 62012: 12013: 122014: 22019: 12023: 1, 1 Class I2024: 4, 2 Class I2025: 3
2007high 12 (2013) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · GWM

441in 2025

2007: 1262008: 1052009: 1172010: 1042011: 1842012: 1512013: 1202014: 3602015: 4862016: 4192017: 4452018: 3022019: 2602020: 2682021: 2112022: 4242023: 7442024: 6412025: 441
2007high 744 (2023) · low 104 (2010)2025

MAUDE reports naming product code GWM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0126
20082—1105
20091—0117
20102—9104
201131236184
201241001151
20132—12120
20142—2360
20150—0486
201631920419
20173370445
20181—0302
20192—1260
20203300268
20212—0211
20220—0424
20230—1 (1)744
20242—4 (2)641
20251—3441
20261—0—

What is it indicated for?

The Pressio® Ventricular Intracranial Pressure Monitoring Kit with Tunneling, Model PSO-VT, is indicated for use in intraventricular pressure monitoring and cerebrospinal fluid drainage applications.

The Pressio® Intracranial Parenchymal Pressure Monitoring Kit with Tunneling, Model PSO-PT, is indicated for use in subdural or parenchymal pressure monitoring.

The Pressio® Intracranial Parenchymal Pressure Monitoring Kit with Bolt, Model PSO-PB, is indicated for use in parenchymal pressure monitoring.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062584: Pressio Icp Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K062584

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026