510(k) Report

510(k) · Cleared

Cleared

Audit Microcv Immunoassay Linearity Set

K062668510(k) TraditionalCleared Oct 16, 200638-day reviewClass I21 CFR 862.1660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aalto Scientific, Ltd. · JJY Multi-Analyte Controls, All Kinds (Assayed)

Cleared on Oct 16, 2006 as substantially equivalent to K042318 (Aalto Scientific, Ltd., 2004) after a 38-day review. Its family tree reaches back 3 generations to 1991. 2 later devices descend from it.

Decided
Oct 16, 2006
Review
38 days
Class
Class I
Product code
JJY
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K910440 (1991). 2 later devices descend from it, 2 citing it directly.

  1. Root · 3 generations backK910440 Document Reflectance II Linearity Test SetCasco Standards · 1991
  2. 2 generations backK023410 Validate Chem 10 Calibration Verification Test Set, Model 110Maine Standards Co. · 2003
  3. 1 generation backK042318 Audit Microcv General Chemistry Linearity SetAalto Scientific, Ltd. · 2004
  4. This deviceK062668 Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd. · 2006
  5. Descendant · cites it directly · 0 of its ownK112143 Audit Microcv T-Uptake LinearityAalto Scientific, Ltd. · 2012
  6. Descendant · cites it directly · 0 of its ownK103601 Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd. · 2011

Most influential descendants

Showing 2 of 2 · See all
  • K112143Audit Microcv T-Uptake LinearityAalto Scientific, Ltd. · 2012 · cites it directly0descendants
  • K103601Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd. · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K910440Document Reflectance II Linearity Test SetCasco Standards1991—
−2K023410Validate Chem 10 Calibration Verification Test Set, Model 110Maine Standards Co.2003—
−1K042318Audit Microcv General Chemistry Linearity SetAalto Scientific, Ltd.2004—
0 (this device)K062668Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd.2006—
+1K112143Audit Microcv T-Uptake LinearityAalto Scientific, Ltd.2012—
+1K103601Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd.2011—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
FIG. 1 — Lineage of K062668, 1991–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042318Audit Microcv General Chemistry Linearity Set
Summary page 1
…JJY E. Device to Which SubstantialEquivalence is Claimed AuditTM MicroCVTM General Chemistry Linearity Set Aalto Scientific, Ltd., Carlsbad, CA K042318 Page 2.1 of 2.2…
Aalto Scientific, Ltd.2004—

Also cleared against K042318: 11 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112143Audit Microcv T-Uptake LinearityAalto Scientific, Ltd.20120
K103601Audit Microcv Immunoassay Linearity SetAalto Scientific, Ltd.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 1.9 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K112143 (Aalto Scientific, Ltd., 2012) has gone furthest, with 0 descendants of its own.
  • 11 other devices also cite its predicate K042318.

How does its category compare?

All JJY devices

JJY Multi-Analyte Controls, All Kinds (Assayed): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JJY

3in 2017

2007: 112008: 72009: 82010: 102011: 142012: 132013: 162014: 102015: 42016: 12017: 3
2007high 16 (2013) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJY

78in 2017

2007: 49 days median2008: 54 days median2009: 80 days median2010: 109 days median2011: 120 days median2012: 40 days median2013: 82 days median2014: 49 days median2015: 153 days median2017: 78 days median
2007high 153 (2015) · low 40 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJY

2in 2025

2007: 52009: 22010: 62011: 12012: 32013: 22014: 22015: 12016: 32017: 42018: 32019: 42020: 62022: 32023: 32025: 22026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJY

13in 2025

2007: 22008: 12009: 32010: 32011: 62012: 202013: 52014: 42015: 42016: 132017: 122018: 72019: 12020: 72021: 12023: 42024: 12025: 13
2007high 20 (2012) · low 0 (2022)2025

MAUDE reports naming product code JJY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007114952
200875401
200988023
20101010963
20111412016
20121340320
2013168225
2014104924
2015415314
20161—313
2017378412
20180—37
20190—41
20200—67
20210—01
20220—30
20230—34
20240—01
20250—213
20260—1—

What is it indicated for?

The AuditTM MicroCVTM Immunoassay Linearity Set consists of five levels in Human and Bovine serum albumin matrix. Each level contains the following analytes: Cortisol, Digoxin, Estradiol, Ferritin, Folate, Free T4, FSH, hCG, LH, Progesterone, Prolactin, Testosterone, Total PSA, Total T3, Total T4, TSH, and Vitamin B12. The five levels demonstrate a linear relationship to each other for their respective analytes, reagents, and instruments. This product…

Read the full statement (153 words)

The AuditTM MicroCVTM Immunoassay Linearity Set consists of five levels in Human and Bovine serum albumin matrix. Each level contains the following analytes: Cortisol, Digoxin, Estradiol, Ferritin, Folate, Free T4, FSH, hCG, LH, Progesterone, Prolactin, Testosterone, Total PSA, Total T3, Total T4, TSH, and Vitamin B12. The five levels demonstrate a linear relationship to each other for their respective analytes, reagents, and instruments.

This product may be used for proficiency testing in interlaboratory surveys and to perform CLIA directed calibration verification for these same analytes with similar reagents on similar instrumentation in accordance with current CLIA-88 guidelines and regulations.

In addition, Level A - E of this product may be used as unassayed quality control material for these analytes or as an assayed quality control material for the analyzer systems specified in the package insert. It is not intended to be used as an assayed quality control material for any other analyzer systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062668: Audit Microcv Immunoassay Linearity Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062668

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026