510(k) Report

510(k) · Cleared

Cleared

Jindell High Spped Air Turbine Handpiece, Models SW, SP, SU, Etu, MU

K062740510(k) TraditionalCleared Nov 2, 200650-day reviewClass I21 CFR 872.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Jindell Medical Instruments Co., Ltd. · EFB Handpiece, Air-Powered, Dental

Cleared on Nov 2, 2006 as substantially equivalent to K052822 (Thunder Tiger Corp., 2006) after a 50-day review. Its family tree reaches back 3 generations to 1995. 21 later devices descend from it.

Decided
Nov 2, 2006
Review
50 days
Class
Class I
Product code
EFB
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K935676 (1995). 21 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2010: 2 descendants cleared2011: 1 descendant cleared2015: 2 descendants cleared2012: 1 descendant cleared2013: 1 descendant cleared2022: 1 descendant cleared2023: 3 descendants cleared2021: 1 descendant cleared2019: 1 descendant cleared2024: 2 descendants cleared2018: 1 descendant cleared2017: 1 descendant cleared2020: 2 descendants cleared2026: 1 descendant clearedK935676 · Micro RSH High Speed Handpiece · Micro Motors, Inc. · 1995K033213 · Codent Dental Air-Powered Handpiece, Model HPS · Codent Technical Industry Co., Ltd. · 2004K052822 · Dental Air-Powered Handpiece, Models Tiger 100, 101, 200, 201 and 202 · Thunder Tiger Corp. · 20061995200020052010201520202025
Descendants, by generation 1 generation forward: 4 descendants2 generations forward: 2 descendants3 generations forward: 5 descendants4 generations forward: 2 descendants5 generations forward: 4 descendants6 generations forward: 2 descendants7 generations forward: 1 descendant8 generations forward: 1 descendant K052822 · Dental Air-Powered Handpiece, Models Tiger 100, 101, 200, 201 and 202 · Thunder Tiger Corp. · 2006K033213 · Codent Dental Air-Powered Handpiece, Model HPS · Codent Technical Industry Co., Ltd. · 2004K935676 · Micro RSH High Speed Handpiece · Micro Motors, Inc. · 19950+5
  1. Root · 3 generations backK935676 Micro RSH High Speed HandpieceMicro Motors, Inc. · 1995
  2. 2 generations backK033213 Codent Dental Air-Powered Handpiece, Model HPSCodent Technical Industry Co., Ltd. · 2004
  3. 1 generation backK052822 Dental Air-Powered Handpiece, Models Tiger 100, 101, 200, 201 and 202Thunder Tiger Corp. · 2006
  4. This deviceK062740 Jindell High Spped Air Turbine Handpiece, Models SW, SP, SU, Etu, MUJindell Medical Instruments Co., Ltd. · 2006
  5. Descendant · cites it directly · 17 of its ownK101717 Dental Handpieces, Models: Karam STD/Mini; Breeze STD/Mini: Karam…Aerobine, Inc. · 2010
  6. Descendant · 2 generations on · 16 of its ownK112024 TI-Max X450Nakanishi, Inc. · 2012
  7. Descendant · 3 generations on · 9 of its ownK130455 430 SWL 45 and 430 SW 45 High-Speed HandpiecesDentalez Group, Stardental Division · 2013
  8. Descendant · 4 generations on · 8 of its ownK152146 High Speed Handpieces and AccessoriesCodent Technical Industry Co., Ltd. · 2015
  9. Descendant · 5 generations on · 4 of its ownK170229 Dental High-speed Turbine HandpieceGuangdong Jinme Medical Technology Co., Ltd. · 2017

Showing 5 of 21 descendants. See all descendants

Descendants cleared per year

2009: 12010: 22011: 12012: 12013: 12015: 22017: 12018: 12019: 12020: 22021: 12022: 12023: 32024: 22026: 1
2009high 3 (2023) · low 0 (2014)2026

Most influential descendants

Showing 5 of 21 · See all
  • K101717Dental Handpieces, Models: Karam STD/Mini; Breeze STD/Mini: Karam 45; Dexor 45; Karam 4H…Aerobine, Inc. · 2010 · cites it directly17descendants
  • K112024TI-Max X450Nakanishi, Inc. · 2012 · 2 generations on16descendants
  • K130455430 SWL 45 and 430 SW 45 High-Speed HandpiecesDentalez Group, Stardental Division · 2013 · 3 generations on9descendants
  • K152146High Speed Handpieces and AccessoriesCodent Technical Industry Co., Ltd. · 2015 · 4 generations on8descendants
  • K170229Dental High-speed Turbine HandpieceGuangdong Jinme Medical Technology Co., Ltd. · 2017 · 5 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K935676Micro RSH High Speed HandpieceMicro Motors, Inc.1995—
−2K033213Codent Dental Air-Powered Handpiece, Model HPSCodent Technical Industry Co., Ltd.2004—
−1K052822Dental Air-Powered Handpiece, Models Tiger 100, 101, 200, 201 and 202Thunder Tiger Corp.2006—
0 (this device)K062740Jindell High Spped Air Turbine Handpiece, Models SW, SP, SU, Etu, MUJindell Medical Instruments Co., Ltd.2006—
+1K101717Dental Handpieces, Models: Karam STD/Mini; Breeze STD/Mini: Karam 45; Dexor…Aerobine, Inc.2010—
+2K112024TI-Max X450Nakanishi, Inc.2012—
+3K130455430 SWL 45 and 430 SW 45 High-Speed HandpiecesDentalez Group, Stardental Division2013—
+4K152146High Speed Handpieces and AccessoriesCodent Technical Industry Co., Ltd.2015—
+5K170229Dental High-speed Turbine HandpieceGuangdong Jinme Medical Technology Co., Ltd.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201020
201110
201210
201310
201520
201710
201810
201910
202020
202110
202210
202330
202420
202610
FIG. 1 — Lineage of K062740, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EFB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EFB device

  1. #1 K262144 DIAMED Handpiece;DIAMED Airmotor;DIAMED…score 13.3 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052822Dental Air-Powered Handpiece, Models Tiger 100, 101, 200, 201 and 202
Summary page 1
…models: TIGER 100, TIGER 101, TIGER 200, TIGER 201, TIGER 202 510K No -K052822 * Statement of Intended Use: The JINDELL High Speed Air Turbine Handpieces are intended for removing c…
Thunder Tiger Corp.2006—

Also cleared against K052822: 5 other devices →

What descends from it? (21)

See all 21

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101717Dental Handpieces, Models: Karam STD/Mini; Breeze STD/Mini: Karam 45; Dexor 45; Karam 4H…Aerobine, Inc.201017
K093084Rolence Dental High Speed Handpiece, RHPRolence Ent., Inc.20092
K101551Pacemaker High-Speed Handpiece Model PM-MQ, PM-MDelma Medical Instrument (Guangzhou) Co., Ltd.20101
K112623Airlight Dental HandpieceBeyes Dental Canada, Inc.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 4 companies; a new generation was cleared every 2.0 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K101717 (Aerobine, Inc., 2010) has gone furthest, with 17 descendants of its own.
  • 5 other devices also cite its predicate K052822.

How does its category compare?

All EFB devices

EFB Handpiece, Air-Powered, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EFB

1in 2025

2007: 122008: 72009: 112010: 82011: 42012: 82013: 32014: 72015: 72016: 32017: 72018: 32019: 32020: 52021: 22022: 52023: 42024: 52025: 12026 (partial year): 4
2007high 12 (2007) · low 1 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EFB

209in 2024

2007: 61 days median2008: 97 days median2009: 120 days median2010: 116 days median2011: 168 days median2012: 130 days median2013: 207 days median2014: 200 days median2015: 296 days median2016: 205 days median2017: 246 days median2018: 210 days median2019: 348 days median2020: 259 days median2022: 430 days median2023: 158 days median2024: 209 days median2026 (partial year): 252 days median
2007high 430 (2022) · low 61 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EFB

No recall names EFB since 2007.

Adverse event reports per year · EFB

83in 2025

2007: 132008: 192009: 402010: 782011: 962012: 972013: 612014: 732015: 872016: 1222017: 1532018: 812019: 1172020: 942021: 1232022: 1572023: 1162024: 1042025: 83
2007high 157 (2022) · low 13 (2007)2025

MAUDE reports naming product code EFB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071261013
2008797019
200911120040
20108116078
20114168096
20128130097
20133207061
20147200073
20157296087
201632050122
201772460153
20183210081
201933480117
20205259094
20212—0123
202254300157
202341580116
202452090104
20251—083
202642520—

What is it indicated for?

JINDELL High Speed Air Turbine Handpiece, models: SW, SP SU, ETU, MU are intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth.

JINDELL High Speed Air Turbine Handpiece carries the following label:

CAUTION: Federal (US) law restricts the use of this device to licensed professionals.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062740: Jindell High Spped Air Turbine Handpiece, Models SW, SP, SU, Etu, MU.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062740

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026