510(k) Report

510(k) · Cleared

Cleared

Pipeline II Access System

K062814510(k) TraditionalCleared Dec 15, 200686-day reviewClass II21 CFR 882.4800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Depuy Spine, Inc. · GZT Retractor, Self-Retaining, For Neurosurgery

Cleared on Dec 15, 2006 as substantially equivalent to K992898 (Bright Medical Instruments, 1999) after an 86-day review. Its family tree reaches back 1 generation to 1999. 2 later devices descend from it.

Decided
Dec 15, 2006
Review
86 days
Class
Class II
Product code
GZT
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K992898 (1999). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2012: 1 descendant cleared2011: 1 descendant clearedK992898 · The Bright Medical Dilation Retractor System · Bright Medical Instruments · 19991995200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants K992898 · The Bright Medical Dilation Retractor System · Bright Medical Instruments · 19990
  1. Root · 1 generation backK992898 The Bright Medical Dilation Retractor SystemBright Medical Instruments · 1999
  2. This deviceK062814 Pipeline II Access SystemDepuy Spine, Inc. · 2006
  3. Descendant · cites it directly · 0 of its ownK113273 Spotlight Access SystemJohnson & Johnson · 2012
  4. Descendant · cites it directly · 0 of its ownK112913 Spotlight Access SystemJohnson & Johnson · 2011

Most influential descendants

Showing 2 of 2 · See all
  • K113273Spotlight Access SystemJohnson & Johnson · 2012 · cites it directly0descendants
  • K112913Spotlight Access SystemJohnson & Johnson · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K992898The Bright Medical Dilation Retractor SystemBright Medical Instruments1999—
0 (this device)K062814Pipeline II Access SystemDepuy Spine, Inc.2006—
+1K113273Spotlight Access SystemJohnson & Johnson2012—
+1K112913Spotlight Access SystemJohnson & Johnson2011—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
FIG. 1 — Lineage of K062814, 1999–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GZT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZT device

  1. #1 K252995 Durashield Device Kitscore 12.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992898The Bright Medical Dilation Retractor System
Summary page 1
…For Neurosurgery §882.4800 PROPRIETARY NAME: PIPELINE 1IAccess System PREDICATE DEVICE: Bright Medical Dilation Retractor System, K992898 DEVICE DESCRIPTION: The PIPELINE 11Access System consists of a series of dilators and tubular retra…
Bright Medical Instruments1999—

Also cleared against K992898: 5 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K113273Spotlight Access SystemJohnson & Johnson20120
K112913Spotlight Access SystemJohnson & Johnson20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K113273 (Johnson & Johnson, 2012) has gone furthest, with 0 descendants of its own.
  • 5 other devices also cite its predicate K992898.

How does its category compare?

All GZT devices

GZT Retractor, Self-Retaining, For Neurosurgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GZT

1in 2022

2007: 22009: 12010: 12011: 12012: 22015: 12016: 12017: 32018: 12020: 12021: 12022: 12026 (partial year): 1
2007high 3 (2017) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZT

280in 2017

2017: 280 days median
2007high 280 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZT

1in 2012

2007: 12012: 1, 1 Class I
2007high 1 (2007) · low 0 (2008)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GZT

1in 2025

2009: 12010: 42011: 42012: 62013: 122014: 162015: 42016: 52017: 92018: 32019: 52020: 32021: 22022: 42023: 22024: 82025: 1
2007high 16 (2014) · low 0 (2007)2025

MAUDE reports naming product code GZT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—10
20080—00
20091—01
20101—04
20111—04
20122—1 (1)6
20130—012
20140—016
20151—04
20161—05
2017328009
20181—03
20190—05
20201—03
20211—02
20221—04
20230—02
20240—08
20250—01
20261—0—

What is it indicated for?

The PIPELINE Access System is intended to provide the surgeon with minimally invasive surgical access to the spine by ensuring the placement/positioning of the port, down to the lamina, with its attachment to a rigid arm to provide a self-locking method of access to the spinal site which can be visualized using a microscope or loupes, and through which surgical instruments can be manipulated.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062814: Pipeline II Access System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062814

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026