Novosci Corp. · MPB Catheter, Hemodialysis, Non-Implanted

Cleared on Jul 27, 2007 as substantially equivalent to K963446 (Kendall Healthcare Products Co. Div.Of Tyco Health, 1997) and 2 other predicates after a 262-day review. Its family tree reaches back 2 generations to 1995. 1 of the 6 devices in its family, counting itself, has a Class I recall. 1 later device descends from it.

Decided
Jul 27, 2007
Review
262 days
Class
Class II
Product code
MPB
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K941851 (1995). 4 ancestors in all. 1 later device descends from it, 1 citing it directly. 1 of the 6 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor, 1 with a Class I recall11999: 1 other ancestor2011: 1 descendant clearedK941851 · Dual Lumen Catheter (DLC) Tray · Neostar Medical Technologies, Inc. · 1995 · recalledK963446 · Kendall Dual Lumen Catheter · Kendall Healthcare Products Co. Div.Of Tyco Health · 19971995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors, 1 with a Class I recall1 1 generation forward: 1 descendant K963446 · Kendall Dual Lumen Catheter · Kendall Healthcare Products Co. Div.Of Tyco Health · 1997K941851 · Dual Lumen Catheter (DLC) Tray · Neostar Medical Technologies, Inc. · 1995 · recalled0
  1. Root · 2 generations backK941851 Dual Lumen Catheter (DLC) TrayNeostar Medical Technologies, Inc. · 1995 · Recalled
  2. 1 generation backK963446 Kendall Dual Lumen CatheterKendall Healthcare Products Co. Div.Of Tyco Health · 1997
  3. This deviceK063355 D-Line Catheter ST, Double Lumen ST; Extra FlowNovosci Corp. · 2007
  4. Descendant · cites it directly · 0 of its ownK102833 Disposable Hemodialysis Access Catheter SetsFoshan Nanhai Bai HE Medical Technology Co., Ltd. · 2011

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K102833Disposable Hemodialysis Access Catheter SetsFoshan Nanhai Bai HE Medical Technology Co., Ltd. · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941851Dual Lumen Catheter (DLC) TrayNeostar Medical Technologies, Inc.19951
−1K963446Kendall Dual Lumen CatheterKendall Healthcare Products Co. Div.Of Tyco Health1997—
0 (this device)K063355D-Line Catheter ST, Double Lumen ST; Extra FlowNovosci Corp.2007—
+1K102833Disposable Hemodialysis Access Catheter SetsFoshan Nanhai Bai HE Medical Technology Co., Ltd.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
200311

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
FIG. 1 — Lineage of K063355, 1995–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MPB device

  1. #1 K250836 14F Duo-Flow® Side X Side Double Lumen Catheterscore 10.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K963446Kendall Dual Lumen Catheter
Summary page 1
…ation Name: 78 MPB-Catheter, Hemodialysis, Non-implanted 21 CFR 876.5540 (b)(2) 3. Predicate Device Kendall Mahurkar Catheter, K963446 Kendall Mahurkar QPlus Catheter, K030209 Medcomp Duo-flow Catheter, K974236 4. Description of Device The Joline…
Kendall Healthcare Products Co. Div.Of Tyco Health1997—
*K030209Mahurkar Oplus Catheter, Model 13.5 FR
Summary page 1
…n-implanted 21 CFR 876.5540 (b)(2) 3. Predicate Device Kendall Mahurkar Catheter, K963446 Kendall Mahurkar QPlus Catheter, K030209 Medcomp Duo-flow Catheter, K974236 4. Description of Device The Joline D-Line Catheter ST family of catheters, consist…
The Kendall Company2003Class I
*K974236Medcomp Schon XL Soft-Line Double Lumen Catheter, 15CM SBF146, Medcomp Schon XL…
Summary page 1
…21 CFR 876.5540 (b)(2) 3. Predicate Device Kendall Mahurkar Catheter, K963446 Kendall Mahurkar QPlus Catheter, K030209 Medcomp Duo-flow Catheter, K974236 4. Description of Device The Joline D-Line Catheter ST family of catheters, consisting of the Dual Lumen Short Term Hemodi…
Medical Components, Inc.1999—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102833Disposable Hemodialysis Access Catheter SetsFoshan Nanhai Bai HE Medical Technology Co., Ltd.20110

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K030209Mahurkar Oplus Catheter, Model 13.5 FRThe Kendall Company · 2003 · Direct predicate · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 10.4 years on median.
  • 2 of the 4 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K102833 (Foshan Nanhai Bai HE Medical Technology Co., Ltd., 2011) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MPB devices

MPB Catheter, Hemodialysis, Non-Implanted: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MPB

1in 2025

2007: 32009: 12010: 12011: 22012: 12013: 12016: 12017: 22020: 32025: 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MPB

205in 2020

2007: 136 days median2020: 205 days median
2007high 205 (2020) · low 136 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MPB

4so far in 2026, the most since 2007

2007: 12017: 22026 (partial year): 4, 3 Class I
2007high 4 (2026) · low 0 (2008)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · MPB

187in 2025

2007: 412008: 1472009: 1662010: 602011: 742012: 782013: 1242014: 822015: 512016: 702017: 862018: 1202019: 1192020: 1792021: 1922022: 1662023: 2032024: 1812025: 187
2007high 203 (2023) · low 41 (2007)2025

MAUDE reports naming product code MPB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073136141
20080—0147
20091—0166
20101—060
20112—074
20121—078
20131—0124
20140—082
20150—051
20161—070
20172—286
20180—0120
20190—0119
202032050179
20210—0192
20220—0166
20230—0203
20240—0181
20251—0187
20260—4 (3)—

What is it indicated for?

The Dual Lumen Short Term Hemodialysis and Extra Flow (EF) Short Term Hemodialysis catheters are indicated for use in hemodialysis, hemoperfusion and apheresis for short-term duration of less than 30 days via the subclavian, femoral or jugular vein

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063355: D-Line Catheter ST, Double Lumen ST; Extra Flow.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K063355

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026