510(k) · Cleared
ClearedVitality Hip System Model#420
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Encore Medical L.P. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Cleared on May 23, 2007 after a 139-day review. The FDA summary names no predicate by number.
- Decided
- May 23, 2007
- Review
- 139 days
- Class
- Class II
- Product code
- LPH
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LPH device
- #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.3 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LPH devicesLPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · LPH
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LPH
153in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LPH
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LPH
6,163in 2025
MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 116 | 16 | 509 |
| 2008 | 10 | 86 | 1 | 706 |
| 2009 | 3 | 112 | 2 | 1,156 |
| 2010 | 15 | 100 | 22 | 2,007 |
| 2011 | 16 | 110 | 26 | 3,320 |
| 2012 | 25 | 76 | 30 | 3,785 |
| 2013 | 11 | 135 | 9 | 5,002 |
| 2014 | 20 | 129 | 3 | 5,163 |
| 2015 | 18 | 111 | 1 | 5,830 |
| 2016 | 10 | 150 | 8 | 4,900 |
| 2017 | 12 | 121 | 14 | 5,312 |
| 2018 | 9 | 145 | 2 | 5,954 |
| 2019 | 22 | 164 | 8 | 7,130 |
| 2020 | 7 | 164 | 6 | 5,429 |
| 2021 | 8 | 410 | 4 | 5,978 |
| 2022 | 14 | 247 | 2 | 5,223 |
| 2023 | 10 | 111 | 2 | 5,345 |
| 2024 | 6 | 92 | 1 | 5,626 |
| 2025 | 12 | 153 | 4 | 6,163 |
| 2026 | 8 | 256 | 2 | — |
What is it indicated for?
Joint replacement is indicated for patients suffering from disability due to: * noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis of the natural femoral head; * rheumatoid arthritis; * correction of functional deformity; * femoral fracture This device may also be indicated in the salvage of previously failed surgical attempts. The Encore hip systems are for total hip replacement except for the bipolar or unipolar…
Read the full statement (136 words)
Joint replacement is indicated for patients suffering from disability due to:
* noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis of the natural femoral head;
* rheumatoid arthritis;
* correction of functional deformity;
* femoral fracture
This device may also be indicated in the salvage of previously failed surgical attempts.
The Encore hip systems are for total hip replacement except for the bipolar or unipolar hip systems which are for hemi-afftroplasty applications. The CLP Offset, CLP-R, and Stamina hip systems are for either total or hemi-applications.
The following Hip Systems are for Cementless application:
Linear Stamina Keystone Modular Revelation
Foundation Press-Fit CLP Offset CLP I Foundation Fracture
The following hip systems are for cemented application:
Vitality Foundation Cemented
The following hip systems are for either cemented or cementless applications:
Alpha Il CLP R R120 R12OPC
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070050 · printed Nov 4, 2026
Cite this page
510(k) Report. “K070050: Vitality Hip System Model#420.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K070050
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026