ClearedFresenius Renal Acute Care (Rac 100) Filter, Model 0500610N
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fresenius Medical Care North America · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System
Cleared on Apr 24, 2007 as substantially equivalent to K003498 (Fresenius Medical Care North America, 2001) and 2 other predicates after a 90-day review. Its family tree reaches back 3 generations to 1994.
- Decided
- Apr 24, 2007
- Review
- 90 days
- Class
- Class II
- Product code
- KDI
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 3 generations to K924437 (1994). 6 ancestors in all. No later device cites it as a predicate yet.
- Root · 3 generations backK924437 Hemospal Kit B22 / Multiflow 60 KitC.G.H. Medical, Inc. · 1994
- 2 generations backK980386 Hospal Multiflow 100, Multiflow 100 Kits A0 (A0,A0/B and A0/0)…Gambro Healthcare · 1999 · Recalled
- 1 generation backK032431 Prisma M60/M100 SetsGambro, Inc. · 2003 · Recalled
- This deviceK070222 Fresenius Renal Acute Care (Rac 100) Filter, Model 0500610NFresenius Medical Care North America · 2007
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K924437 | Hemospal Kit B22 / Multiflow 60 Kit | C.G.H. Medical, Inc. | 1994 | — |
| −2 | K980386 | Hospal Multiflow 100, Multiflow 100 Kits A0 (A0,A0/B and A0/0), Multiflow 100… | Gambro Healthcare | 1999 | 1 |
| −1 | K032431 | Prisma M60/M100 Sets | Gambro, Inc. | 2003 | 6 |
| 0 (this device) | K070222 | Fresenius Renal Acute Care (Rac 100) Filter, Model 0500610N | Fresenius Medical Care North America | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 1998 | 1 | 0 |
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KDI device
- #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K003498 | Fresenius Optiflux 200ASummary page 2…Hemofilter and the Gambro M100 Hemofilter, Gambro Hospal Multiflow 100: * K980386 (2/24/99) Gambro M100 * K032431 (9/15/03) Optiflux F16ONR * K003498 (1/4/01) D. Indications for Use/Intended Use: Intended for use in removing solutes or fluid in renal supportive therapie… | 2001 |
| * | K980386 | Hospal Multiflow 100, Multiflow 100 Kits A0 (A0,A0/B and A0/0), Multiflow 100 Kits B22…Summary page 2…tially equivalent to the Fresenius Optiflux F16ONR, Gambro Hospal Multiflow 100 Hemofilter and the Gambro M100 Hemofilter, Gambro Hospal Multiflow 100: * K980386 (2/24/99) Gambro M100 * K032431 (9/15/03) Optiflux F16ONR * K003498 (1/4/01) D. Indications for Use/Intended Use:… | 1999 |
| * | K032431 | Prisma M60/M100 SetsSummary page 2…ptiflux F16ONR, Gambro Hospal Multiflow 100 Hemofilter and the Gambro M100 Hemofilter, Gambro Hospal Multiflow 100: * K980386 (2/24/99) Gambro M100 * K032431 (9/15/03) Optiflux F16ONR * K003498 (1/4/01) D. Indications for Use/Intended Use: Intended for use in removing so… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 4.6 years on median.
- 4 of the 6 ancestors have a recall of any class.
- 1 other device also cites its predicate K003498.
How does its category compare?
All KDI devicesKDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · KDI
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KDI
199in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KDI
2in 2025
Class I (10 since 2007) Class II/III not classified
Adverse event reports per year · KDI
2,786in 2025
MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 11 | 91 | 4 | 916 |
| 2008 | 6 | 148 | 0 | 1,042 |
| 2009 | 4 | 236 | 3 | 522 |
| 2010 | 9 | 186 | 1 | 823 |
| 2011 | 5 | 85 | 4 | 2,270 |
| 2012 | 6 | 153 | 1 | 1,765 |
| 2013 | 11 | 247 | 2 | 2,360 |
| 2014 | 8 | 164 | 3 | 6,154 |
| 2015 | 5 | 69 | 5 | 4,182 |
| 2016 | 5 | 230 | 4 | 766 |
| 2017 | 8 | 188 | 1 | 963 |
| 2018 | 2 | — | 1 | 1,716 |
| 2019 | 4 | 263 | 6 | 1,587 |
| 2020 | 9 | 266 | 0 | 1,633 |
| 2021 | 2 | — | 2 | 1,944 |
| 2022 | 7 | 259 | 17 | 2,180 |
| 2023 | 7 | 157 | 8 (8) | 2,692 |
| 2024 | 7 | 235 | 4 (2) | 2,441 |
| 2025 | 9 | 199 | 2 | 2,786 |
| 2026 | 6 | 154 | 2 | — |
What is it indicated for?
Intended for use in removing solutes or fluid in renal supportive therapies in an acute setting. This filter can be used for intermittent and continuous therapies.
The RAC 100 Filter is intended for use in the following continuous veno-venous therapies:
* continuous veno-venous hemofiltration (CVVH)
* continuous veno-venous hemodialysis (CVVHD)
The RAC 100 Filter is intended for use in the following intermittent therapies, e.g. slow low efficiency dialysis (SLED) or other renal supportive therapies of less than 8 hours duration.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070222 · printed Nov 6, 2026
Cite this page
510(k) Report. “K070222: Fresenius Renal Acute Care (Rac 100) Filter, Model 0500610N.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070222
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026