Duragen XS Dural Regeneration Matrix

K072207510(k) SpecialCleared Aug 23, 200715-day reviewClass II21 CFR 882.5910Recalls 6

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Lifesciences Corp. · GXQ Dura Substitute

Cleared on Aug 23, 2007 as substantially equivalent to K032693 (Integra Lifesciences Corp., 2003) after a 15-day review. Its family tree reaches back 4 generations to 1995. 2 later devices descend from it. It has been recalled 6 times.

Decided
Aug 23, 2007
Review
15 days
Class
Class II
Product code
GXQ
Recalls
6
Predicates
1

Its longest line of descent runs back 4 generations to K950956 (1995). 7 ancestors in all, the oldest K910555 (1992). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1995: 1 other ancestor1992: 1 other ancestor2012: 1 descendant cleared2017: 1 descendant clearedK950956 · Dura-Guard Dural Repair Patch, Dura-Guard Dura Substitute · Bio-Vascular, Inc. · 1995K973706 · Dura-Guard-Dural Repair Patch · Bio-Vascular, Inc. · 1997K982180 · Duragen Dural Graft Matrix · Integra Lifesciences Corp. · 1999 · recalledK032693 · Duragen Plus Dural Graft Matrix · Integra Lifesciences Corp. · 2003 · recalled1990200020102020
  1. Root · 4 generations backK950956 Dura-Guard Dural Repair Patch, Dura-Guard Dura SubstituteBio-Vascular, Inc. · 1995
  2. 3 generations backK973706 Dura-Guard-Dural Repair PatchBio-Vascular, Inc. · 1997
  3. 2 generations backK982180 Duragen Dural Graft MatrixIntegra Lifesciences Corp. · 1999 · Recalled
  4. 1 generation backK032693 Duragen Plus Dural Graft MatrixIntegra Lifesciences Corp. · 2003 · Recalled
  5. This deviceK072207 Duragen XS Dural Regeneration MatrixIntegra Lifesciences Corp. · 2007
  6. Descendant · cites it directly · 1 of its ownK120600 Duragen Secure Dural Regneration MatrixIntegra Life Sciences · 2012
  7. Descendant · 2 generations on · 0 of its ownK163456 DuraGen Secure Dural Regeneration MatrixIntegra LifeSciences Corporation · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K120600Duragen Secure Dural Regneration MatrixIntegra Life Sciences · 2012 · cites it directly1descendant
  • K163456DuraGen Secure Dural Regeneration MatrixIntegra LifeSciences Corporation · 2017 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K950956Dura-Guard Dural Repair Patch, Dura-Guard Dura SubstituteBio-Vascular, Inc.1995—
−3K973706Dura-Guard-Dural Repair PatchBio-Vascular, Inc.1997—
−2K982180Duragen Dural Graft MatrixIntegra Lifesciences Corp.19991
−1K032693Duragen Plus Dural Graft MatrixIntegra Lifesciences Corp.20031
0 (this device)K072207Duragen XS Dural Regeneration MatrixIntegra Lifesciences Corp.2007—
+1K120600Duragen Secure Dural Regneration MatrixIntegra Life Sciences2012—
+2K163456DuraGen Secure Dural Regeneration MatrixIntegra LifeSciences Corporation2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199510
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201710
FIG. 1 — Lineage of K072207, 1995–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXQ device

  1. #1 K251191 Collagen Dura Regeneration Membrane - Repairscore 12.2 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032693Duragen Plus Dural Graft Matrix
Summary page 1
…e: The DuraGen XSTm Dural Regeneration Matrix is substantially equivalent in function and intended use to the currently marketed DuraGen Plus® Dural Regeneration Matrix (K032693). Intended Use: DuraGen XSTm Dural Regeneration Matrix is indicated as a dura substitute for the repair of dura mater. Device D…
Integra Lifesciences Corp.20031

Also cleared against K032693: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K120600Duragen Secure Dural Regneration MatrixIntegra Life Sciences20121

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 28, 2013Class IIZ-1285-2013Process controlDue to the process deviation, product lots in question may have been released with higher levels of pyrogens than permitted by the specifications for the products.
Mar 28, 2013Class IIZ-1286-2013Process controlDue to the process deviation, product lots in question may have been released with higher levels of pyrogens than permitted by the specifications for the products.
Sep 29, 2010Not classifiedZ-0450-2011OtherTest results no longer support a 3 year shelf life.
Sep 29, 2010Not classifiedZ-0451-2011OtherTest results no longer support a 3 year shelf life.
Sep 29, 2010Not classifiedZ-0452-2011OtherTest results no longer support a 3 year shelf life.
Sep 29, 2010Not classifiedZ-0453-2011OtherTest results no longer support a 3 year shelf life.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 2 companies; a new generation was cleared every 3.9 years on median.
  • 2 of the 7 ancestors have a recall of any class.
  • Of its descendants, K120600 (Integra Life Sciences, 2012) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K032693.

How does its category compare?

All GXQ devices

GXQ Dura Substitute: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GXQ

2in 2025

2007: 22010: 12012: 22013: 32014: 12015: 32016: 32017: 22019: 12022: 12023: 12025: 2
2007high 3 (2013) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXQ

94in 2016

2013: 181 days median2015: 214 days median2016: 94 days median
2007high 214 (2015) · low 94 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXQ

2in 2024

2010: 62013: 12021: 22024: 2
2007high 6 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXQ

61in 2025

2007: 552008: 432009: 462010: 362011: 312012: 382013: 722014: 182015: 622016: 582017: 572018: 942019: 632020: 1142021: 762022: 592023: 1092024: 552025: 61
2007high 114 (2020) · low 18 (2014)2025

MAUDE reports naming product code GXQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—055
20080—043
20090—046
20101—636
20110—031
20122—038
20133181172
20141—018
20153214062
2016394058
20172—057
20180—094
20191—063
20200—0114
20210—276
20221—059
20231—0109
20240—255
20252—061
20260—0—

What is it indicated for?

DuraGen XSTM Dural Regeneration Matrix is indicated as a dura substitute for the repair of dura mater.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072207: Duragen XS Dural Regeneration Matrix.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K072207

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026