510(k) Report

510(k) · Cleared

Cleared

Modification to Space Cpsxl Bone Cement

K072496510(k) SpecialCleared Oct 5, 200730-day reviewClass II21 CFR 888.3027

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dfine, Inc. · NDN Cement, Bone, Vertebroplasty

Cleared on Oct 5, 2007 as substantially equivalent to K061531 (Dfine, Inc., 2006) after a 30-day review. Its family tree reaches back 5 generations to 2001. 1 later device descends from it.

Decided
Oct 5, 2007
Review
30 days
Class
Class II
Product code
NDN
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K002652 (2001). 6 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 5 generations backK002652 Surgical Simplex P Radiopaque Bone Cement and Acm and MixevaciiStryker Corp. · 2001 · Recalled
  2. 4 generations backK033801 Kyphx HV-R, Model C01AKyphon, Inc. · 2004 · Recalled
  3. 3 generations backK041584 Kyphx HV-R Bone Cement, Model C01AKyphon, Inc. · 2004 · Recalled
  4. 2 generations backK042415 Mendec SpineTecres S.P.A. · 2005
  5. 1 generation backK061531 Space Cpsxl Bone CementDfine, Inc. · 2006
  6. This deviceK072496 Modification to Space Cpsxl Bone CementDfine, Inc. · 2007
  7. Descendant · cites it directly · 0 of its ownK090986 Stabili Erx Bone Cement, Model 1135,Stabilit Vertebral Augmentation…Dfine, Inc. · 2009

Most influential descendants

Showing 1 of 1 · See all
  • K090986Stabili Erx Bone Cement, Model 1135,Stabilit Vertebral Augmentation System (for Use W/…Dfine, Inc. · 2009 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K002652Surgical Simplex P Radiopaque Bone Cement and Acm and MixevaciiStryker Corp.20011
−4K033801Kyphx HV-R, Model C01AKyphon, Inc.20042
−3K041584Kyphx HV-R Bone Cement, Model C01AKyphon, Inc.20042
−2K042415Mendec SpineTecres S.P.A.2005—
−1K061531Space Cpsxl Bone CementDfine, Inc.2006—
0 (this device)K072496Modification to Space Cpsxl Bone CementDfine, Inc.2007—
+1K090986Stabili Erx Bone Cement, Model 1135,Stabilit Vertebral Augmentation System…Dfine, Inc.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
FIG. 1 — Lineage of K072496, 2001–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NDN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NDN device

  1. #1 K241775 XeliteMed VertehighFix High Viscosity Spinal…score 14.9 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061531Space Cpsxl Bone Cement
Summary page 1
…cement is substantially equivalent to other bone cements intended for vertebroplasty, including SPACE CpsXL bone cement, cleared under 510(k) K061531 by DFine, Inc. San Jose, CA. 4. Intended use of the device The SPACE CpsXL bone cement is indicated fo…
Dfine, Inc.2006—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K090986Stabili Erx Bone Cement, Model 1135,Stabilit Vertebral Augmentation System (for Use W/…Dfine, Inc.20090

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 4 companies; a new generation was cleared every 1.1 years on median.
  • 4 of the 6 ancestors have a recall of any class.
  • Of its descendants, K090986 (Dfine, Inc., 2009) has gone furthest, with 0 descendants of its own.

How does its category compare?

All NDN devices

NDN Cement, Bone, Vertebroplasty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · NDN

2in 2025

2007: 92008: 12009: 62010: 52011: 112012: 72013: 72014: 72015: 62016: 42017: 52018: 32019: 22020: 42021: 22022: 22023: 22024: 32025: 22026 (partial year): 1
2007high 11 (2011) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NDN

90in 2024

2007: 128 days median2009: 211 days median2010: 215 days median2011: 164 days median2012: 90 days median2013: 118 days median2014: 106 days median2015: 76 days median2016: 154 days median2017: 125 days median2018: 111 days median2020: 157 days median2024: 90 days median
2007high 215 (2010) · low 76 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NDN

4in 2013

2009: 12013: 4
2007high 4 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NDN

626in 2025

2007: 212008: 392009: 702010: 3962011: 982012: 892013: 2422014: 2312015: 2042016: 1822017: 1912018: 1442019: 2272020: 2122021: 3442022: 2702023: 3112024: 4542025: 626
2007high 626 (2025) · low 21 (2007)2025

MAUDE reports naming product code NDN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079128021
20081—039
20096211170
201052150396
201111164098
2012790089
201371184242
201471060231
20156760204
201641540182
201751250191
201831110144
20192—0227
202041570212
20212—0344
20222—0270
20232—0311
20243900454
20252—0626
20261—0—

What is it indicated for?

The SPACE CpsXL bone cement is indicated for the treatment of pathological fractures of the vertebrae using a vertebroplasty or kyphoplasty procedure. Painful vertebral compression fractures may result from osteoporosis, benign lesions (hemangioma) and malignant lesions (metastatic cancers, myeloma).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072496: Modification to Space Cpsxl Bone Cement.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K072496

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026