510(k) Report

510(k) · Cleared

Cleared

Pulmodyne CHF Flow Generator System

K080256510(k) TraditionalCleared May 9, 200899-day reviewClass II21 CFR 868.5965

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pulmodyne · BYE Attachment, Breathing, Positive End Expiratory Pressure

Cleared on May 9, 2008 as substantially equivalent to K982283 (Caradyne, Ltd., 1999) after a 99-day review. Its family tree reaches back 2 generations to 1980. 1 of the 8 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it.

Decided
May 9, 2008
Review
99 days
Class
Class II
Product code
BYE
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K801883 (1980). 5 ancestors in all. 2 later devices descend from it, 2 citing it directly. 1 of the 8 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1987: 1 other ancestor1983: 1 other ancestor1981: 1 other ancestor2013: 2 descendants cleared, 1 with a Class I recall1K801883 · Peep Face Mask · Vital Signs, Inc. · 1980K982283 · Whisperflow Oxygen Flow Generator - Adjustable Model WF 8500 Whisperflow Oxygen Flow Generator - Fixed Model WF 8530 WH · Caradyne, Ltd. · 199919801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 3 other ancestors 1 generation forward: 2 descendants, 1 with a Class I recall1 K982283 · Whisperflow Oxygen Flow Generator - Adjustable Model WF 8500 Whisperflow Oxygen Flow Generator - Fixed Model WF 8530 WH · Caradyne, Ltd. · 1999K801883 · Peep Face Mask · Vital Signs, Inc. · 19800
  1. Root · 2 generations backK801883 Peep Face MaskVital Signs, Inc. · 1980
  2. 1 generation backK982283 Whisperflow Oxygen Flow Generator - Adjustable Model WF 8500…Caradyne, Ltd. · 1999
  3. This deviceK080256 Pulmodyne CHF Flow Generator SystemPulmodyne · 2008
  4. Descendant · cites it directly · 0 of its ownK123957 Pneupac Parapac PlusSmiths Medical International, Ltd. · 2013 · Recalled (Class I)
  5. Descendant · cites it directly · 0 of its ownK122610 Plaxtron Cpap System, Model CH-FFM-87XX/CH-FFM-88XX SeriesSen MU Technology Co., Ltd. · 2013

Class I recalls in this family

Most influential descendants

Showing 2 of 2 · See all
  • K123957Pneupac Parapac PlusSmiths Medical International, Ltd. · 2013 · cites it directly0descendants
  • K122610Plaxtron Cpap System, Model CH-FFM-87XX/CH-FFM-88XX SeriesSen MU Technology Co., Ltd. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K801883Peep Face MaskVital Signs, Inc.1980—
−1K982283Whisperflow Oxygen Flow Generator - Adjustable Model WF 8500 Whisperflow…Caradyne, Ltd.1999—
0 (this device)K080256Pulmodyne CHF Flow Generator SystemPulmodyne2008—
+1K123957Pneupac Parapac PlusSmiths Medical International, Ltd.2013Class I
+1K122610Plaxtron Cpap System, Model CH-FFM-87XX/CH-FFM-88XX SeriesSen MU Technology Co., Ltd.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198310
198710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201321
FIG. 1 — Lineage of K080256, 1980–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K982283Whisperflow Oxygen Flow Generator - Adjustable Model WF 8500 Whisperflow Oxygen Flow…
Summary page 1
…Attachment Positive End Expiratory Pressure BYE - 868.5965 Predicate Devices: Caradyne - Whisperflow - K982283 Device Description: The Pulmodyne CHF Flow Generator is a venturi type oxygen / air mixture delivery device which provides CPAP…
Caradyne, Ltd.1999—

Also cleared against K982283: 3 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K123957Pneupac Parapac Plus Class ISmiths Medical International, Ltd.20130
K122610Plaxtron Cpap System, Model CH-FFM-87XX/CH-FFM-88XX SeriesSen MU Technology Co., Ltd.20130

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K123957Pneupac Parapac PlusSmiths Medical International, Ltd. · 2013 · Cites it directly · ◆ in the 2013 descendants bar of FIG. 16 Class I recalls

What does this lineage say?

  • The line of descent spans 28 years and passes through 3 companies; a new generation was cleared every 18.5 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K123957 (Smiths Medical International, Ltd., 2013) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K982283.

How does its category compare?

All BYE devices

BYE Attachment, Breathing, Positive End Expiratory Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · BYE

1in 2016

2007: 12008: 12009: 32010: 12011: 32013: 12014: 22016: 1
2007high 3 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BYE

117in 2011

2009: 155 days median2011: 117 days median
2007high 155 (2009) · low 117 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BYE

1in 2015

2007: 42008: 22015: 12026 (partial year): 1, 1 Class I
2007high 4 (2007) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · BYE

7in 2025

2007: 82008: 32009: 12010: 42011: 22012: 62013: 22014: 82015: 42017: 32018: 112019: 52020: 52021: 42022: 102023: 82024: 92025: 7
2007high 11 (2018) · low 0 (2016)2025

MAUDE reports naming product code BYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—48
20081—23
2009315501
20101—04
2011311702
20120—06
20131—02
20142—08
20150—14
20161—00
20170—03
20180—011
20190—05
20200—05
20210—04
20220—010
20230—08
20240—09
20250—07
20260—1 (1)—

What is it indicated for?

To provide CPAP to spontaneously breathing adult patients in the hospital and pre-hospital (EMS) environment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080256: Pulmodyne CHF Flow Generator System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K080256

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026