510(k) Report

510(k) · Cleared

Cleared

Continuous Cardiac Ouput Monitor, Truccom

K081776510(k) SpecialCleared Jul 22, 200829-day reviewClass II21 CFR 870.1435

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Omega Critical Care Limited · DXG Computer, Diagnostic, Pre-Programmed, Single-Function

Cleared on Jul 22, 2008 as substantially equivalent to K993245 (Alba Critical Care, Ltd., 1999) after a 29-day review. Its family tree reaches back 2 generations to 1993.

Decided
Jul 22, 2008
Review
29 days
Class
Class II
Product code
DXG
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K925444 (1993). No later device cites it as a predicate yet.

  1. Root · 2 generations backK925444 Cardiac Output Pulmonary Artery Catheter & MonitorAmi-Med Corp. · 1993
  2. 1 generation backK993245 Continous Cardiac Output Pulmonary Artery Catheter, Model Trucath…Alba Critical Care, Ltd. · 1999
  3. This deviceK081776 Continuous Cardiac Ouput Monitor, TruccomOmega Critical Care Limited · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K925444Cardiac Output Pulmonary Artery Catheter & MonitorAmi-Med Corp.1993—
−1K993245Continous Cardiac Output Pulmonary Artery Catheter, Model Trucath, Continous…Alba Critical Care, Ltd.1999—
0 (this device)K081776Continuous Cardiac Ouput Monitor, TruccomOmega Critical Care Limited2008—
FIG. 1 — Lineage of K081776, 1993–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXG device

  1. #1 K253092 Argos Infinity (Rev. 1.0)score 11.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993245Continous Cardiac Output Pulmonary Artery Catheter, Model Trucath, Continous Cardiac…
Summary page 1
…Continuous Output Pulmonary Artery Catheter and Continuous Outout Monitor, 510(k) number K993245 Omega Critical Care Special 510(k): Device Modification Device Description: The Continuous C…
Alba Critical Care, Ltd.1999—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 8.7 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All DXG devices

DXG Computer, Diagnostic, Pre-Programmed, Single-Function: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · DXG

1in 2025

2007: 12008: 52010: 42011: 32012: 22013: 32014: 62015: 12016: 12017: 12018: 22019: 22020: 12021: 12023: 12025: 12026 (partial year): 1
2007high 6 (2014) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXG

290in 2014

2008: 118 days median2010: 282 days median2011: 104 days median2013: 236 days median2014: 290 days median
2007high 290 (2014) · low 104 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXG

2in 2020

2007: 12008: 12009: 62010: 12020: 2
2007high 6 (2009) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXG

8in 2025

2007: 432008: 372009: 82010: 172011: 72012: 292013: 232014: 442015: 342016: 672017: 622018: 832019: 812020: 492021: 292022: 442023: 122024: 212025: 8
2007high 83 (2018) · low 7 (2011)2025

MAUDE reports naming product code DXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—143
20085118137
20090—68
20104282117
2011310407
20122—029
20133236023
20146290044
20151—034
20161—067
20171—062
20182—083
20192—081
20201—249
20211—029
20220—044
20231—012
20240—021
20251—08
20261—0—

What is it indicated for?

The Continuous Cardiac Output Pulmonary Artery Catheter and Continuous Cardiac Output Monitor systems intended use is for the assessment of a patients haemodynamic condition through direct intracardiac (right heart) and pulmonary artery pressure monitoring, cardiac output determination and for infusing solutions. The distal port on the catheter also allows for sampling of venous blood.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K081776: Continuous Cardiac Ouput Monitor, Truccom.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K081776

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026