510(k) Report

510(k) · Cleared

Cleared

Renu Medical Oximetry Sensor, Adult, Ped, Inf,Neo

K081927510(k) TraditionalCleared Feb 6, 2009214-day reviewClass II21 CFR 870.2700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Renu Medical, Inc. · NLF Oximeter, Reprocessed

Cleared on Feb 6, 2009 after a 214-day review. The FDA summary names its predicate without a number. 1 later device descends from it.

Decided
Feb 6, 2009
Review
214 days
Class
Class II
Product code
NLF
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared20052010201520202025
  1. This deviceK081927 Renu Medical Oximetry Sensor, Adult, Ped, Inf,NeoRenu Medical, Inc. · 2009
  2. Descendant · cites it directly · 0 of its ownK111773 Renu Medical Reprocessed Oximax Sensors: Adult, Pediatric, Infant…Renu Medical, Inc. · 2011

Most influential descendants

Showing 1 of 1 · See all
  • K111773Renu Medical Reprocessed Oximax Sensors: Adult, Pediatric, Infant and NeonateRenu Medical, Inc. · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K081927Renu Medical Oximetry Sensor, Adult, Ped, Inf,NeoRenu Medical, Inc.2009—
+1K111773Renu Medical Reprocessed Oximax Sensors: Adult, Pediatric, Infant and NeonateRenu Medical, Inc.2011—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
FIG. 1 — Lineage of K081927, 2009–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NLF device

  1. #1 K241758 Reprocessed RD SET Adt Pulse Oximeter Sensor…score 14.5 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Masimo LNCS Adtx Oximetry sensor
Named without a submission number
—
*—Masimo LNCS Pdtx Oximetry sensor
Named without a submission number
—
*—Masimo LNCS Inf Oximetry sensor
Named without a submission number
—
*—Masimo LNCS Neo Oximetry sensor
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111773Renu Medical Reprocessed Oximax Sensors: Adult, Pediatric, Infant and NeonateRenu Medical, Inc.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K111773 (Renu Medical, Inc., 2011) has gone furthest, with 0 descendants of its own.

How does its category compare?

All NLF devices

NLF Oximeter, Reprocessed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · NLF

1in 2024

2007: 22008: 22009: 32010: 12011: 32019: 12020: 12022: 22024: 1
2007high 3 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NLF

146in 2011

2009: 214 days median2011: 146 days median
2007high 214 (2009) · low 146 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NLF

3in 2008

2008: 3
2007high 3 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NLF

3in 2025

2008: 72009: 32010: 22011: 42012: 52013: 62014: 32015: 32016: 42017: 42018: 82019: 112020: 22021: 12022: 22023: 42024: 12025: 3
2007high 11 (2019) · low 0 (2007)2025

MAUDE reports naming product code NLF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20082—37
2009321403
20101—02
2011314604
20120—05
20130—06
20140—03
20150—03
20160—04
20170—04
20180—08
20191—011
20201—02
20210—01
20222—02
20230—04
20241—01
20250—03
20260—0—

What is it indicated for?

The ReNu Medical Reprocessed Oximetry Sensors are intended as single patient use 02 transducer/accessory sensors for use in conjunction with the Masimo TMMOximeter system.

The LNCS Adult is used for patients >30 kg.

The LNCS Pediatric is used for patients 10-50 kg.

The LNCS Infant is used for patients 3-20 kg.

The LNCS Neo is used for neonates <3 kg or adults >40 kg.

All sensors are used for non-invasive monitoring of pulse oxygen hemoglobin saturation (Sp02) and pulse rate.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K081927: Renu Medical Oximetry Sensor, Adult, Ped, Inf,Neo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K081927

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026