510(k) Report

510(k) · Cleared

Cleared

Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensor

K201699510(k) SpecialCleared Jul 22, 202030-day reviewClass II21 CFR 870.2700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Surgical Instrument and Savings Inc (Dba Medline Renewal) · NLF Oximeter, Reprocessed

Cleared on Jul 22, 2020 as substantially equivalent to K181738 (Surgical Instrument Service and Savings Inc (Dba Medline, 2019) after a 30-day review. Its family tree reaches back 8 generations to 1997.

Decided
Jul 22, 2020
Review
30 days
Class
Class II
Product code
NLF
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K962603 (1997). 12 ancestors in all, the oldest K904039 (1990). No later device cites it as a predicate yet.

  1. Root · 8 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 7 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 6 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 5 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 4 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 3 generations backK021089 Oximax Max-Fast Adhesive Forehead SensorNellcor Puritan Bennett, Inc. · 2002
  7. 2 generations backK052186 Nellcor Oximax Pulse Oximetry Sensons (Max-a, Max-AL, Max-N, Max-I…Nellcor Puritan Bennett, Inc. · 2005
  8. 1 generation backK181738 Medline ReNewal Reprocessed OxiMax Pulse Oximetry SensorsSurgical Instrument Service and Savings Inc (Dba Medline · 2019
  9. This deviceK201699 Medline ReNewal Reprocessed Nellcor OxiMax SpO2 SensorSurgical Instrument and Savings Inc (Dba Medline Renewal) · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−7K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−6K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−5K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−4K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−3K021089Oximax Max-Fast Adhesive Forehead SensorNellcor Puritan Bennett, Inc.2002—
−2K052186Nellcor Oximax Pulse Oximetry Sensons (Max-a, Max-AL, Max-N, Max-I, Max-PNellcor Puritan Bennett, Inc.2005—
−1K181738Medline ReNewal Reprocessed OxiMax Pulse Oximetry SensorsSurgical Instrument Service and Savings Inc (Dba Medline2019—
0 (this device)K201699Medline ReNewal Reprocessed Nellcor OxiMax SpO2 SensorSurgical Instrument and Savings Inc (Dba Medline Renewal)2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199510
199610
199910
FIG. 1 — Lineage of K201699, 1997–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NLF device

  1. #1 K241758 Reprocessed RD SET Adt Pulse Oximeter Sensor…score 14.5 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K181738Medline ReNewal Reprocessed OxiMax Pulse Oximetry Sensors
Summary page 5
…Name/Reference: Regulatory Class: Class II Product Code: NLF 510(k) number: K181738 (March 22, 2019) Proprietary/Trade Medline ReNewal Reprocessed Nellcor OxiMax SpO2 N…
Surgical Instrument Service and Savings Inc (Dba Medline2019—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 5 companies; a new generation was cleared every 1.3 years on median.
  • 3 of the 12 ancestors have a recall of any class.

How does its category compare?

All NLF devices

NLF Oximeter, Reprocessed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · NLF

1in 2024

2007: 22008: 22009: 32010: 12011: 32019: 12020: 12022: 22024: 1
2007high 3 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NLF

146in 2011

2009: 214 days median2011: 146 days median
2007high 214 (2009) · low 146 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NLF

3in 2008

2008: 3
2007high 3 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NLF

3in 2025

2008: 72009: 32010: 22011: 42012: 52013: 62014: 32015: 32016: 42017: 42018: 82019: 112020: 22021: 12022: 22023: 42024: 12025: 3
2007high 11 (2019) · low 0 (2007)2025

MAUDE reports naming product code NLF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20082—37
2009321403
20101—02
2011314604
20120—05
20130—06
20140—03
20150—03
20160—04
20170—04
20180—08
20191—011
20201—02
20210—01
20222—02
20230—04
20241—01
20250—03
20260—0—

What is it indicated for?

The Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensor Model MAXNAR is indicated for single patient use when continuous non-invasive arterial oxygen saturation and pulse rate monitoring is required for adult patients as indicated in the sensor directions for use. This device is for prescription use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201699: Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K201699

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026