510(k) Report

510(k) · Cleared

Cleared

Roll-X Guidewire

K082304510(k) TraditionalCleared Aug 27, 200814-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

St Jude Medical · DQX Wire, Guide, Catheter

Cleared on Aug 27, 2008 as substantially equivalent to K052339 (Asahi Intecc Co., Ltd., 2005) and 1 other predicate after a 14-day review. Its family tree reaches back 7 generations to 1989. 2 later devices descend from it.

Decided
Aug 27, 2008
Review
14 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K890505 (1989). 17 ancestors in all. 2 later devices descend from it, 2 citing it directly.

  1. Root · 7 generations backK890505 Usci Grey/Black Guide WireC.R. Bard, Inc. · 1989
  2. 6 generations backK961271 Usci Commander Series Guide WiresC.R. Bard, Inc. · 1996
  3. 5 generations backK990639 Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with…Guidant Corp. · 1999
  4. 4 generations backK022762 Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000…Jomed, Inc. · 2002
  5. 3 generations backK031277 Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc. · 2003
  6. 2 generations backK041531 Asahi Ptca Guide Wire Confianza ProAsahi Intecc Co., Ltd. · 2004
  7. 1 generation backK052339 Asahi Ptca Guide WireAsahi Intecc Co., Ltd. · 2005
  8. This deviceK082304 Roll-X GuidewireSt Jude Medical · 2008
  9. Descendant · cites it directly · 0 of its ownK101729 Neowire Pta/Ptca GuidewireNeometrics, Inc. · 2010
  10. Descendant · cites it directly · 0 of its ownK100710 Roll-X GuidewireSt Jude Medical · 2010

Most influential descendants

Showing 2 of 2 · See all
  • K101729Neowire Pta/Ptca GuidewireNeometrics, Inc. · 2010 · cites it directly0descendants
  • K100710Roll-X GuidewireSt Jude Medical · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K890505Usci Grey/Black Guide WireC.R. Bard, Inc.1989—
−6K961271Usci Commander Series Guide WiresC.R. Bard, Inc.1996—
−5K990639Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with Hydrocoat…Guidant Corp.1999—
−4K022762Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000, AG143000…Jomed, Inc.2002—
−3K031277Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc.2003—
−2K041531Asahi Ptca Guide Wire Confianza ProAsahi Intecc Co., Ltd.2004—
−1K052339Asahi Ptca Guide WireAsahi Intecc Co., Ltd.2005—
0 (this device)K082304Roll-X GuidewireSt Jude Medical2008—
+1K101729Neowire Pta/Ptca GuidewireNeometrics, Inc.2010—
+1K100710Roll-X GuidewireSt Jude Medical2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199310
199510
199720
199830
200010
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201020
FIG. 1 — Lineage of K082304, 1989–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052339Asahi Ptca Guide Wire
Summary page 1
…Catheter Guide Wire (870.1330) Product Code: DQX 3. PREDICATE DEVICE INFORMATION Asahi Prowater PTCA Coronary Guidewire (Abbott)- K052339 cleared Nov 2005 Hi-Torque Balanced Middleweight Universal (Abbott)- K013833 cleared Jan 2002 4. DEVICE DESCRIPTION R…
Asahi Intecc Co., Ltd.2005—
*K013833HI-Toque Balance Middleweight Universal Guide Wire with Hydrocoat Hydrophilic Coating…
Summary page 1
…DQX 3. PREDICATE DEVICE INFORMATION Asahi Prowater PTCA Coronary Guidewire (Abbott)- K052339 cleared Nov 2005 Hi-Torque Balanced Middleweight Universal (Abbott)- K013833 cleared Jan 2002 4. DEVICE DESCRIPTION Roll-XTM Guidewire is a steerable guide wire constructed of a stainless steel…
Guidant Corp.2002—

Also cleared against K052339: 8 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101729Neowire Pta/Ptca GuidewireNeometrics, Inc.20100
K100710Roll-X GuidewireSt Jude Medical20100

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 5 companies; a new generation was cleared every 2.7 years on median.
  • None of the 17 ancestors has a recall.
  • Of its descendants, K101729 (Neometrics, Inc., 2010) has gone furthest, with 0 descendants of its own.
  • 8 other devices also cite its predicate K052339.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

Roll-X Coronary Guidewires are intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The wire is also intended to facilitate the placement of compatible stent devices during therapeutic intravascular procedures. The Guidewire is not to be used in the cerebral blood vessels.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082304: Roll-X Guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K082304

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026