510(k) Report

510(k) · Cleared

Cleared

Neowire Pta/Ptca Guidewire

K101729510(k) TraditionalCleared Sep 23, 201094-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neometrics, Inc. · DQX Wire, Guide, Catheter

Cleared on Sep 23, 2010 as substantially equivalent to K070150 (Neometrics, Inc., 2007) and 4 other predicates after a 94-day review. Its family tree reaches back 8 generations to 1989. 1 of the 29 devices in its family, counting itself, has a Class I recall.

Decided
Sep 23, 2010
Review
94 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
5

Its longest line of descent runs back 8 generations to K890505 (1989). 28 ancestors in all. No later device cites it as a predicate yet. 1 of the 29 devices in this family, counting this one, has a Class I recall.

  1. Root · 8 generations backK890505 Usci Grey/Black Guide WireC.R. Bard, Inc. · 1989
  2. 7 generations backK961271 Usci Commander Series Guide WiresC.R. Bard, Inc. · 1996
  3. 6 generations backK990639 Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with…Guidant Corp. · 1999
  4. 5 generations backK022762 Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000…Jomed, Inc. · 2002
  5. 4 generations backK031277 Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc. · 2003
  6. 3 generations backK041531 Asahi Ptca Guide Wire Confianza ProAsahi Intecc Co., Ltd. · 2004
  7. 2 generations backK052339 Asahi Ptca Guide WireAsahi Intecc Co., Ltd. · 2005
  8. 1 generation backK082304 Roll-X GuidewireSt Jude Medical · 2008
  9. This deviceK101729 Neowire Pta/Ptca GuidewireNeometrics, Inc. · 2010

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K890505Usci Grey/Black Guide WireC.R. Bard, Inc.1989—
−7K961271Usci Commander Series Guide WiresC.R. Bard, Inc.1996—
−6K990639Acs HI-Torque Cross IT 100XT, 200XT and 300XT Guide Wires with Hydrocoat…Guidant Corp.1999—
−5K022762Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000, AG143000…Jomed, Inc.2002—
−4K031277Jowire Asahi Ptca Catheter Guide Wires, Models…Jomed, Inc.2003—
−3K041531Asahi Ptca Guide Wire Confianza ProAsahi Intecc Co., Ltd.2004—
−2K052339Asahi Ptca Guide WireAsahi Intecc Co., Ltd.2005—
−1K082304Roll-X GuidewireSt Jude Medical2008—
0 (this device)K101729Neowire Pta/Ptca GuidewireNeometrics, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199310
199510
199720
199840
199911
200010
200120
200220
200310
200410
200510
200710
200810
FIG. 1 — Lineage of K101729, 1989–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070150Vascupuncture Picc Guidewire
Summary page 1
…nformation The following commercially available guidewires are predicate devices for NeoWire. 510(k) Number Trade or Model Name Manufacturer K(070150 VascuPuncture PICC Guidewire Neolvetrics, Inc. K983927 ZingerGuidewire Me…
Neometrics, Inc.2007—
*K983927GT1 Floppy, GT1 HI-Per Flex, GT1 Light Support
Summary page 1
…evices for NeoWire. 510(k) Number Trade or Model Name Manufacturer K(070150 VascuPuncture PICC Guidewire Neolvetrics, Inc. K983927 ZingerGuidewire Medtronic K(013024 Selectiva Neolvetri…
Arterial Vascular Engineering, Inc.1999Class I
*K013024Selectiva Guidewire
Summary page 1
…Manufacturer K(070150 VascuPuncture PICC Guidewire Neolvetrics, Inc. K983927 ZingerGuidewire Medtronic K(013024 Selectiva Neolvetrics, Inc. K(082304 RolI-X St…
Neometrics, Inc.2001—
*K082304Roll-X Guidewire
Summary page 1
…Neolvetrics, Inc. K983927 ZingerGuidewire Medtronic K(013024 Selectiva Neolvetrics, Inc. K(082304 RolI-X St. Jude Medical K(081337 Approach CTO Coo…
St Jude Medical2008—
*K081337Approach Cto Wire Guide
Summary page 1
…Medtronic K(013024 Selectiva Neolvetrics, Inc. K(082304 RolI-X St. Jude Medical K(081337 Approach CTO Cook 5.4 Device Description NeoWire isa steerable guidewire constructed o…
Cook Incorporated2008—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K983927GT1 Floppy, GT1 HI-Per Flex, GT1 Light SupportArterial Vascular Engineering, Inc. · 1999 · Direct predicate · ◆ in the 1999 ancestors bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 2.7 years on median.
  • 1 of the 28 ancestors has a recall of any class; 1 has a Class I recall.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

The N~eoWire Guidewire is Intended to facilitate the Introduction and placement of catheters and interventional devices within the coronary and/or peripheral vasculature. Models with stiff tips I(> 9g) are intended for peripheral use only. Models with Floppy, Soft, and Medium tips (5 9g) are Intended for peripheral or coronary use. The guidewire Isnot Intended for use Inthe cerebral vasculature.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K101729: Neowire Pta/Ptca Guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K101729

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026