510(k) · Cleared
ClearedSubcutaneous Needle Infusion Set
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Marcal Medical, Inc. · FPA Set, Administration, Intravascular
Cleared on Dec 23, 2008 as substantially equivalent to K020530 (Evans Medical, Inc., 2002) and 1 other predicate after an 89-day review. Its family tree reaches back 3 generations to 1983. 6 later devices descend from it.
- Decided
- Dec 23, 2008
- Review
- 89 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 3 generations to K831445 (1983). 5 ancestors in all. 6 later devices descend from it, 4 citing it directly.
- Root · 3 generations backK831445 Infusion Sets #'S 124 & 142 PersonalPacesetter Systems · 1983
- 2 generations backK961474 Polyfin Infusion Set MMT-106/MMT-107/MMT-133Medtronic Minimed · 1996
- 1 generation backK020530 Evans Sub-Q, Model MC4206Evans Medical, Inc. · 2002
- This deviceK082818 Subcutaneous Needle Infusion SetMarcal Medical, Inc. · 2008
- Descendant · cites it directly · 3 of its ownK102512 RMS Subcutaneous Needle SetRepro-Med Systems, Inc. · 2011
- Descendant · 2 generations on · 0 of its ownK202279 Insignis Subcutaneous Needle SetsInnovative Health Sciences, LLC · 2021
- Descendant · cites it directly · 0 of its ownK122404 Model Number: RMS1-2604, RMS1-2614, RMS1-2404, RMS1-2414, RMS2-2604…Repro-Med Systems, Inc. Dba Rms Medical Products · 2013 · Recalled
- Descendant · cites it directly · 0 of its ownK120195 Safety Subcutaneous Tissue Infusion SetMulti Med · 2012
- Descendant · 2 generations on · 0 of its ownK121092 Flowease [Subcutaneous] Infusion SetBaxter Healthcare Corp · 2012
Showing 5 of 6 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 6 · See all- K102512RMS Subcutaneous Needle SetRepro-Med Systems, Inc. · 2011 · cites it directly3descendants
- K202279Insignis Subcutaneous Needle SetsInnovative Health Sciences, LLC · 2021 · 2 generations on0descendants
- K122404Model Number: RMS1-2604, RMS1-2614, RMS1-2404, RMS1-2414, RMS2-2604, RMS2-2614…Repro-Med Systems, Inc. Dba Rms Medical Products · 2013 · cites it directly0descendants
- K120195Safety Subcutaneous Tissue Infusion SetMulti Med · 2012 · cites it directly0descendants
- K121092Flowease [Subcutaneous] Infusion SetBaxter Healthcare Corp · 2012 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K831445 | Infusion Sets #'S 124 & 142 Personal | Pacesetter Systems | 1983 | — |
| −2 | K961474 | Polyfin Infusion Set MMT-106/MMT-107/MMT-133 | Medtronic Minimed | 1996 | — |
| −1 | K020530 | Evans Sub-Q, Model MC4206 | Evans Medical, Inc. | 2002 | — |
| 0 (this device) | K082818 | Subcutaneous Needle Infusion Set | Marcal Medical, Inc. | 2008 | — |
| +1 | K102512 | RMS Subcutaneous Needle Set | Repro-Med Systems, Inc. | 2011 | — |
| +2 | K202279 | Insignis Subcutaneous Needle Sets | Innovative Health Sciences, LLC | 2021 | — |
| +1 | K122404 | Model Number: RMS1-2604, RMS1-2614, RMS1-2404, RMS1-2414, RMS2-2604… | Repro-Med Systems, Inc. Dba Rms Medical Products | 2013 | 2 |
| +1 | K120195 | Safety Subcutaneous Tissue Infusion Set | Multi Med | 2012 | — |
| +2 | K121092 | Flowease [Subcutaneous] Infusion Set | Baxter Healthcare Corp | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 1 | 0 |
| 1989 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 1 | 0 |
| 2012 | 3 | 0 |
| 2013 | 1 | 0 |
| 2021 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K020530 | Evans Sub-Q, Model MC4206Summary page 1…rauma, and offer an opportunity to improve compliance cost-effectively through the use of a dedicated infusion set. The device is for single use only. Predicate Device: K020530 - Evans Medical, Inc - Evans Sub-Q, Model MC4206 K89 1072 - Multi-Med, Inc - Intravascular Administration Set.… | 2002 |
| * | K891072 | Intravascular Administration SetSummary page 1…t-effectively through the use of a dedicated infusion set. The device is for single use only. Predicate Device: K020530 - Evans Medical, Inc - Evans Sub-Q, Model MC4206 K89 1072 - Multi-Med, Inc - Intravascular Administration Set.… | 1989 |
What descends from it? (6)
4 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 6.7 years on median.
- None of the 5 ancestors has a recall.
- Of its descendants, K102512 (Repro-Med Systems, Inc., 2011) has gone furthest, with 3 descendants of its own.
- 5 other devices also cite its predicate K020530.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
The Subcutaneous Infusion Set is designed specifically for the delivery of medication to the
subcutaneous tissue
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082818 · printed Nov 6, 2026
Cite this page
510(k) Report. “K082818: Subcutaneous Needle Infusion Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082818
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026