510(k) Report

510(k) · Cleared

Cleared

Berichrom Heparin LMW Calibrator, Berichrom Heparin LMW Control 1, and Berichrom Heparin LMW Control 2

K083159510(k) TraditionalCleared Jan 26, 200991-day reviewClass II21 CFR 864.5425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics · JPA System, Multipurpose For In Vitro Coagulation Studies

Cleared on Jan 26, 2009 as substantially equivalent to K030964 (Instrumentation Laboratory CO, 2003) and 1 other predicate after a 91-day review. Its family tree reaches back 2 generations to 2000.

Decided
Jan 26, 2009
Review
91 days
Class
Class II
Product code
JPA
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K002400 (2000). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2003: 1 other ancestorK002400 · Modification of Acl Advance · Instrumentation Laboratory CO · 2000 · recalledK030964 · Calibration Plasma LMW Heparin · Instrumentation Laboratory CO · 2003200020022004200620082010
Other ancestors, by generation 1 generation back: 1 other ancestor K030964 · Calibration Plasma LMW Heparin · Instrumentation Laboratory CO · 2003K002400 · Modification of Acl Advance · Instrumentation Laboratory CO · 2000 · recalled0
  1. Root · 2 generations backK002400 Modification of Acl AdvanceInstrumentation Laboratory CO · 2000 · Recalled
  2. 1 generation backK030964 Calibration Plasma LMW HeparinInstrumentation Laboratory CO · 2003
  3. This deviceK083159 Berichrom Heparin LMW Calibrator, Berichrom Heparin LMW Control 1…Siemens Healthcare Diagnostics · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002400Modification of Acl AdvanceInstrumentation Laboratory CO20002
−1K030964Calibration Plasma LMW HeparinInstrumentation Laboratory CO2003—
0 (this device)K083159Berichrom Heparin LMW Calibrator, Berichrom Heparin LMW Control 1, and…Siemens Healthcare Diagnostics2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K083159, 2000–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JPA device

  1. #1 K243858 TEG 6s Hemostasis System Citrated: K, KH, RT…score 12.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030964Calibration Plasma LMW Heparin
Summary page 2
…II 3 Classification Panel(s) Hematology (81) 4 Product Code(s) JPA, GIZ, GGC D Predicate Device(s) Calibration Plasma LMW Heparn - K030964 Control Plasma LMW Hepann - K030965 E Device Description(s) Benchrom Heparn LMW Calibrator Benchrom Heparn LMW C…
Instrumentation Laboratory CO2003—
*K030965Control Plasma LMW Heparin
Summary page 2
…Hematology (81) 4 Product Code(s) JPA, GIZ, GGC D Predicate Device(s) Calibration Plasma LMW Heparn - K030964 Control Plasma LMW Hepann - K030965 E Device Description(s) Benchrom Heparn LMW Calibrator Benchrom Heparn LMW Calibrator is a !yophilized product contai…
Instrumentation Laboratory CO2003—

Also cleared against K030964: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 5.6 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K030964.

How does its category compare?

All JPA devices

JPA System, Multipurpose For In Vitro Coagulation Studies: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · JPA

3in 2025

2007: 12008: 22009: 62010: 12011: 12013: 12015: 22016: 62017: 42018: 12019: 32021: 12022: 12023: 32024: 12025: 32026 (partial year): 1
2007high 6 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JPA

30in 2025

2009: 91 days median2016: 114 days median2017: 117 days median2019: 175 days median2023: 506 days median2025: 30 days median
2007high 506 (2023) · low 30 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JPA

1in 2020

2007: 12010: 62011: 42012: 12016: 32020: 12026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JPA

11in 2025

2007: 1,7442008: 9182009: 1,3632010: 7272011: 1612012: 522013: 432014: 482015: 452016: 62017: 152018: 392019: 272020: 182021: 72022: 92023: 112024: 82025: 11
2007high 1,744 (2007) · low 6 (2016)2025

MAUDE reports naming product code JPA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—11,744
20082—0918
200969101,363
20101—6727
20111—4161
20120—152
20131—043
20140—048
20152—045
2016611436
20174117015
20181—039
20193175027
20200—118
20211—07
20221—09
20233506011
20241—08
2025330011
20261—1—

What is it indicated for?

Benchrom Heparin LMW Calibrator is an in vitro diagnostic product used for the calibration of the Benchrom Heparin assay for measurement of low molecular weight (LMW) heparin

Benchrom Heparin LMW Control 1 is an assayed, low level, quality control material for assessment of precision and analytical bias in the quantitative determination of low molecular weight (LMW) heparin with the Berichrom Heparin assay

Berichrom Heparin LMW Control 2 is an assayed, high level, quality control material for assessment of precision and analytical bias in the quantitative determination of low molecular weight (LMW) heparin with the Berichrom Heparin assay

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083159: Berichrom Heparin LMW Calibrator, Berichrom Heparin LMW Control 1, and Berichrom Heparin LMW Control 2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083159

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026