510(k) Report

510(k) · Cleared

Cleared

Kubtec Xpert 20

K083510510(k) TraditionalCleared Jan 8, 200943-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kub Technologies, Inc. · KPR System, X-Ray, Stationary

Cleared on Jan 8, 2009 as substantially equivalent to K071233 (Kub Technologies, Inc., 2007) after a 43-day review. Its family tree reaches back 3 generations to 2002. 15 later devices descend from it.

Decided
Jan 8, 2009
Review
43 days
Class
Class II
Product code
KPR
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K021113 (2002). 5 ancestors in all, the oldest K953404 (1995). 15 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor1995: 1 other ancestor2011: 1 descendant cleared2012: 1 descendant cleared2017: 2 descendants cleared2021: 3 descendants cleared2019: 3 descendants cleared2026: 1 descendant cleared2020: 1 descendant cleared2018: 1 descendant cleared2023: 2 descendants clearedK021113 · Mammopath · Fischer Imaging Corp. · 2002K052433 · Pixarray 100 Digital Specimen Radiography (DSR) System · Bioptics, Inc. · 2005K071233 · Xpert 40 Specimen Radiography System · Kub Technologies, Inc. · 20071995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 6 descendants3 generations forward: 4 descendants4 generations forward: 3 descendants5 generations forward: 1 descendant K071233 · Xpert 40 Specimen Radiography System · Kub Technologies, Inc. · 2007K052433 · Pixarray 100 Digital Specimen Radiography (DSR) System · Bioptics, Inc. · 2005K021113 · Mammopath · Fischer Imaging Corp. · 20020+5
  1. Root · 3 generations backK021113 MammopathFischer Imaging Corp. · 2002
  2. 2 generations backK052433 Pixarray 100 Digital Specimen Radiography (DSR) SystemBioptics, Inc. · 2005
  3. 1 generation backK071233 Xpert 40 Specimen Radiography SystemKub Technologies, Inc. · 2007
  4. This deviceK083510 Kubtec Xpert 20Kub Technologies, Inc. · 2009
  5. Descendant · cites it directly · 14 of its ownK111508 Trident Specimen Radiography System, Model : RC Tri-00001Hologic, Inc. · 2011
  6. Descendant · 2 generations on · 4 of its ownK122428 Faxitron Specien Radiography SystemFaxitron Bioptics, LLC · 2012
  7. Descendant · 2 generations on · 3 of its ownK182727 Trident HD Specimen Radiography SystemHologic, Inc. · 2019
  8. Descendant · 3 generations on · 2 of its ownK202713 TrueView 100 ProCompai Healthcare (Shenzhen) Co.,Ltd · 2020
  9. Descendant · 3 generations on · 2 of its ownK170786 Faxitron Bioptics Speciemen Radiography SystemFaxitron Bioptics, LLC · 2017

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2011: 12012: 12017: 22018: 12019: 32020: 12021: 32023: 22026: 1
2011high 3 (2019) · low 0 (2013)2026

Most influential descendants

Showing 5 of 15 · See all
  • K111508Trident Specimen Radiography System, Model : RC Tri-00001Hologic, Inc. · 2011 · cites it directly14descendants
  • K122428Faxitron Specien Radiography SystemFaxitron Bioptics, LLC · 2012 · 2 generations on4descendants
  • K182727Trident HD Specimen Radiography SystemHologic, Inc. · 2019 · 2 generations on3descendants
  • K202713TrueView 100 ProCompai Healthcare (Shenzhen) Co.,Ltd · 2020 · 3 generations on2descendants
  • K170786Faxitron Bioptics Speciemen Radiography SystemFaxitron Bioptics, LLC · 2017 · 3 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K021113MammopathFischer Imaging Corp.2002—
−2K052433Pixarray 100 Digital Specimen Radiography (DSR) SystemBioptics, Inc.2005—
−1K071233Xpert 40 Specimen Radiography SystemKub Technologies, Inc.2007—
0 (this device)K083510Kubtec Xpert 20Kub Technologies, Inc.2009—
+1K111508Trident Specimen Radiography System, Model : RC Tri-00001Hologic, Inc.2011—
+2K122428Faxitron Specien Radiography SystemFaxitron Bioptics, LLC2012—
+2K182727Trident HD Specimen Radiography SystemHologic, Inc.2019—
+3K202713TrueView 100 ProCompai Healthcare (Shenzhen) Co.,Ltd2020—
+3K170786Faxitron Bioptics Speciemen Radiography SystemFaxitron Bioptics, LLC2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
201720
201810
201930
202010
202130
202320
202610
FIG. 1 — Lineage of K083510, 2002–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KPR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPR device

  1. #1 K242119 Innovision-Exiiscore 17.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071233Xpert 40 Specimen Radiography System
Summary page 2
…ography System > XPERT 20 Specimen X-Ray System / Cabinet Class 11, Product Code MWP,-21 CFR 892.1680 Predicate Device [21 CFR 807.92(a)(3)] o XPERT 40 (K071233) Description of the Device [21 CFR 807.92(a)(4)] The XPERT Specimen Radiography System is a self contained, shielded cabi…
Kub Technologies, Inc.2007—

Also cleared against K071233: 4 other devices →

What descends from it? (15)

See all 15

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111508Trident Specimen Radiography System, Model : RC Tri-00001Hologic, Inc.201114

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 1.7 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K111508 (Hologic, Inc., 2011) has gone furthest, with 14 descendants of its own.
  • 4 other devices also cite its predicate K071233.

How does its category compare?

All KPR devices

KPR System, X-Ray, Stationary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · KPR

8in 2025

2007: 122008: 152009: 92010: 92011: 92012: 112013: 52014: 102015: 182016: 112017: 62018: 152019: 122020: 162021: 62022: 82023: 92024: 112025: 82026 (partial year): 6
2007high 18 (2015) · low 5 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPR

155in 2025

2007: 31 days median2008: 48 days median2009: 35 days median2010: 126 days median2011: 152 days median2012: 58 days median2013: 163 days median2014: 108 days median2015: 81 days median2016: 84 days median2017: 75 days median2018: 30 days median2019: 33 days median2020: 39 days median2021: 55 days median2022: 43 days median2023: 76 days median2024: 162 days median2025: 155 days median2026 (partial year): 197 days median
2007high 197 (2026) · low 30 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPR

7in 2025

2007: 102008: 102009: 52010: 32011: 52012: 12013: 52014: 82015: 12016: 42017: 32018: 42019: 12020: 12022: 22023: 42024: 12025: 7
2007high 10 (2007) · low 0 (2021)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KPR

39in 2025

2007: 1202008: 952009: 612010: 822011: 1032012: 742013: 242014: 342015: 592016: 182017: 312018: 362019: 772020: 412021: 372022: 272023: 392024: 342025: 39
2007high 120 (2007) · low 18 (2016)2025

MAUDE reports naming product code KPR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123110120
200815481095
2009935561
20109126382
201191525103
20121158174
20135163524
201410108834
20151881159
20161184418
2017675331
20181530436
20191233177
20201639141
2021655037
2022843227
2023976439
202411162134
20258155739
202661970—

What is it indicated for?

Provide digital x-ray images of harvested tissue specimens from various anatomical regions in order to provide rapid verification that the correct tissue has been excised during the biopsy procedure.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083510: Kubtec Xpert 20.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083510

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026