510(k) · Cleared
ClearedSynoss Collagen Synthetic Mineral-Collagen Bone Graft Matrix
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Collagen Matrix, Inc. · LYC Bone Grafting Material, Synthetic
Cleared on Feb 12, 2009 as substantially equivalent to K072397 (Collagen Matrix, Inc., 2007) and 2 other predicates after a 58-day review. Its family tree reaches back 4 generations to 1987.
- Decided
- Feb 12, 2009
- Review
- 58 days
- Class
- Class II
- Product code
- LYC
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 4 generations to K871773 (1987). 11 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK871773 Bio-Oss Pure Nat Hydroxyapatite Endoss ImplantGeistlich-Pharma · 1987
- 3 generations backK033815 Bio-Oss, Bio-Oss Blocks and Bio-Oss CollagenGeistlich-Pharma · 2004
- 2 generations backK043034 Osteoguide Anorganic Bone Mineral ProductsCollagen Matrix, Inc. · 2005 · Recalled
- 1 generation backK072397 Synoss Synthetic Bone Graft MaterialCollagen Matrix, Inc. · 2007
- This deviceK083742 Synoss Collagen Synthetic Mineral-Collagen Bone Graft MatrixCollagen Matrix, Inc. · 2009
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K871773 | Bio-Oss Pure Nat Hydroxyapatite Endoss Implant | Geistlich-Pharma | 1987 | — |
| −3 | K033815 | Bio-Oss, Bio-Oss Blocks and Bio-Oss Collagen | Geistlich-Pharma | 2004 | — |
| −2 | K043034 | Osteoguide Anorganic Bone Mineral Products | Collagen Matrix, Inc. | 2005 | 3 |
| −1 | K072397 | Synoss Synthetic Bone Graft Material | Collagen Matrix, Inc. | 2007 | — |
| 0 (this device) | K083742 | Synoss Collagen Synthetic Mineral-Collagen Bone Graft Matrix | Collagen Matrix, Inc. | 2009 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1995 | 2 | 0 |
| 1998 | 2 | 0 |
| 2000 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LYC device
- #1 K253317 Cytrans™ Elashieldscore 14.3 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K072397 | Synoss Synthetic Bone Graft MaterialSummary page 1…LYC Class II Predicate Device(s): SynOss T M Synthetic Bone Graft Material K072397 OsteoGuideTM Anorganic Bone Mineral Products K043034… | 2007 |
| * | K043034 | Osteoguide Anorganic Bone Mineral ProductsSummary page 1…Graft Material K072397 OsteoGuideTM Anorganic Bone Mineral Products K043034 FOUNDATION TM Bone Filling Augmentation Material K040783 De… | 2005 |
| * | K040783 | FoundationSummary page 1…l Products K043034 FOUNDATION TM Bone Filling Augmentation Material K040783 Description of the Device Synthetic Mineral - Collagen Bone Graft Matrix is a composite of synthetic calcium phosphate based g… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 2 companies; a new generation was cleared every 2.2 years on median.
- 1 of the 11 ancestors has a recall of any class.
- 2 other devices also cite its predicate K072397.
How does its category compare?
All LYC devicesLYC Bone Grafting Material, Synthetic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · LYC
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LYC
267in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LYC
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LYC
2in 2025
MAUDE reports naming product code LYC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 80 | 0 | 23 |
| 2008 | 8 | 73 | 0 | 25 |
| 2009 | 14 | 100 | 1 | 25 |
| 2010 | 13 | 164 | 2 | 28 |
| 2011 | 9 | 224 | 0 | 21 |
| 2012 | 5 | 120 | 2 | 10 |
| 2013 | 2 | — | 0 | 12 |
| 2014 | 1 | — | 0 | 9 |
| 2015 | 0 | — | 0 | 14 |
| 2016 | 2 | — | 2 | 140 |
| 2017 | 0 | — | 0 | 19 |
| 2018 | 0 | — | 1 | 14 |
| 2019 | 0 | — | 0 | 15 |
| 2020 | 3 | 156 | 0 | 5 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 2 | — | 0 | 6 |
| 2023 | 0 | — | 0 | 9 |
| 2024 | 0 | — | 0 | 6 |
| 2025 | 3 | 267 | 0 | 2 |
| 2026 | 3 | 266 | 0 | — |
What is it indicated for?
Synthetic Mineral - Collagen Bone Graft Matrix is intended for use in dental surgery. The products may be used in surgical procedures such as:
* Augmentation or reconstructive treatment of alveolar ridge
* Filling of periodontal defects
* Filling of defects after root resection, apicocectomy, and cystectomy
* Filling of extraction sockets to enhance preservation of the alveolar ridge
* Elevation of maxillary sinus floor
* Filling of periodontal defects in conjunction with products intended for Guided Tissue Regeneration (GTR) and Guided Bone Regeneration (GBR)
* Filling of peri-implant defects in conjunction with products intended for Guided Bone Regeneration
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K083742 · printed Nov 6, 2026
Cite this page
510(k) Report. “K083742: Synoss Collagen Synthetic Mineral-Collagen Bone Graft Matrix.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083742
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026