510(k) Report

510(k) · Cleared

Cleared

Lipidpro System

K090405510(k) TraditionalCleared Dec 1, 2009285-day reviewClass II21 CFR 862.1345

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Infopia Co, Ltd. · NBW System, Test, Blood Glucose, Over The Counter

Cleared on Dec 1, 2009 as substantially equivalent to K023558 (Polymer Technology Systems, Inc., 2002) and 2 other predicates after a 285-day review. Its family tree reaches back 3 generations to 1987. 1 later device descends from it.

Decided
Dec 1, 2009
Review
285 days
Class
Class II
Product code
NBW
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K870252 (1987). 16 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2008: 1 other ancestor2002: 2 other ancestors2001: 1 other ancestor2000: 3 other ancestors1999: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor1989: 1 other ancestor1988: 2 other ancestors2013: 1 descendant clearedK870252 · Document (TM) Multi-Analyte Linearity Test Set · Casco Standards · 1987K012117 · Validate Chem 1 Calibration Verification Test Set, Model 10001 · Maine Standards Co. · 2001K022401 · PTS Panels Multi-Chemistry Controls · Polymer Technology Systems, Inc. · 20021990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 5 other ancestors3 generations back: 6 other ancestors 1 generation forward: 1 descendant K022401 · PTS Panels Multi-Chemistry Controls · Polymer Technology Systems, Inc. · 2002K012117 · Validate Chem 1 Calibration Verification Test Set, Model 10001 · Maine Standards Co. · 2001K870252 · Document (TM) Multi-Analyte Linearity Test Set · Casco Standards · 19870
  1. Root · 3 generations backK870252 Document (TM) Multi-Analyte Linearity Test SetCasco Standards · 1987
  2. 2 generations backK012117 Validate Chem 1 Calibration Verification Test Set, Model 10001Maine Standards Co. · 2001
  3. 1 generation backK022401 PTS Panels Multi-Chemistry ControlsPolymer Technology Systems, Inc. · 2002
  4. This deviceK090405 Lipidpro SystemInfopia Co, Ltd. · 2009
  5. Descendant · cites it directly · 0 of its ownK130295 Lipidpro Lipid Profile and Glucose Measuring System, Lipidpro…Infopia Co, Ltd. · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K130295Lipidpro Lipid Profile and Glucose Measuring System, Lipidpro Professional Lipid Profile…Infopia Co, Ltd. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K870252Document (TM) Multi-Analyte Linearity Test SetCasco Standards1987—
−2K012117Validate Chem 1 Calibration Verification Test Set, Model 10001Maine Standards Co.2001—
−1K022401PTS Panels Multi-Chemistry ControlsPolymer Technology Systems, Inc.2002—
0 (this device)K090405Lipidpro SystemInfopia Co, Ltd.2009—
+1K130295Lipidpro Lipid Profile and Glucose Measuring System, Lipidpro Professional…Infopia Co, Ltd.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198820
198910
199510
199610
199910
200030
200110
200220
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K090405, 1987–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NBW device

  1. #1 K260545 CONTOUR® PLUS BLUE Blood Glucose Monitoring…score 14.6 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023558PTS Panels Lipid Panel Test Strips
Summary page 1
…aterial (assayed and unassayed) (21 CFR Part 862.1660, JJX) 6. Predicate - Predicate for the Lipid profile test system PTS PANELS Lipid Panel Test Strips (K023558) / Polymer Technology Systems, Inc. - Predicate for the glucose test system Evolution~m Blood Glucose Test System…
Polymer Technology Systems, Inc.20022
*K072369Evolution Blood Glucose Monitoring System
Summary page 1
…ANELS Lipid Panel Test Strips (K023558) / Polymer Technology Systems, Inc. - Predicate for the glucose test system Evolution~m Blood Glucose Test System (K072369) / HMD Biomedical LLC. LipiPro"m 510(K) Submission…
Hmd Biomedical, LLC2008—
*K022401PTS Panels Multi-Chemistry Controls
Summary page 4
…gally marketed predicate device, PTS PANELS Lipid Panel Test Strips (K023558), Evolutionrh Blood Glucose Test System (K(072369) and PTS Panels Multi-Chemristry Controls (K022401). Similarities and Differences of the Lipid profile measuring system ~~Item…
Polymer Technology Systems, Inc.2002—

Also cleared against K023558: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K130295Lipidpro Lipid Profile and Glucose Measuring System, Lipidpro Professional Lipid Profile…Infopia Co, Ltd.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 7.3 years on median.
  • 3 of the 16 ancestors have a recall of any class.
  • Of its descendants, K130295 (Infopia Co, Ltd., 2013) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K023558.

How does its category compare?

All NBW devices

NBW System, Test, Blood Glucose, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · NBW

2in 2025

2007: 292008: 372009: 382010: 312011: 302012: 302013: 472014: 242015: 322016: 202017: 252018: 192019: 102020: 72021: 72022: 122023: 52024: 72025: 22026 (partial year): 5
2007high 47 (2013) · low 2 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NBW

243in 2024

2007: 85 days median2008: 128 days median2009: 140 days median2010: 132 days median2011: 328 days median2012: 230 days median2013: 167 days median2014: 202 days median2015: 237 days median2016: 233 days median2017: 244 days median2018: 168 days median2019: 127 days median2020: 121 days median2021: 465 days median2022: 410 days median2023: 193 days median2024: 243 days median2026 (partial year): 190 days median
2007high 465 (2021) · low 85 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NBW

1in 2025

2007: 92008: 22009: 52010: 112011: 12012: 12013: 5, 2 Class I2014: 12016: 12019: 142025: 1
2007high 14 (2019) · low 0 (2015)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · NBW

4,745in 2025

2007: 7,9912008: 7,7042009: 10,9632010: 11,6312011: 22,9092012: 23,4492013: 35,4082014: 38,5242015: 62,1112016: 76,6212017: 37,5382018: 16,9112019: 14,4722020: 10,7032021: 9,1982022: 8,1032023: 7,2562024: 6,2202025: 4,745
2007high 76,621 (2016) · low 4,745 (2025)2025

MAUDE reports naming product code NBW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007298597,991
20083712827,704
200938140510,963
2010311321111,631
201130328122,909
201230230123,449
2013471675 (2)35,408
201424202138,524
201532237062,111
201620233176,621
201725244037,538
201819168016,911
2019101271414,472
20207121010,703
2021746509,198
20221241008,103
2023519307,256
2024724306,220
20252—14,745
202651900—

What is it indicated for?

LipidProtm system is intended for in home (self-testing) or health care professionals and for testing outside the body (in vitro diagnostic use only). LipidPro Tm system which consists of meter and test strips, measures total cholesterol (TC), high density lipoprotein cholesterol (HDL-C), triglyceride (TG) and glucose in capillary whole blood. Cholesterol measurements are used in the diagnosis and treatment of disorders involving excess cholesterol in…

Read the full statement (295 words)

LipidProtm system is intended for in home (self-testing) or health care professionals and for testing outside the body (in vitro diagnostic use only). LipidPro Tm system which consists of meter and test strips, measures total cholesterol (TC), high density lipoprotein cholesterol (HDL-C), triglyceride (TG) and glucose in capillary whole blood.

Cholesterol measurements are used in the diagnosis and treatment of disorders involving excess cholesterol in the blood and lipid and lipoprotein metabolism disorders. Lipoprotein measurements are used in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis and various liver and renal diseases. Triglyceride measurements are used in the diagnosis and treatment of patients with diabetes mellitus, nephrosis, liver obstruction, other diseases involving lipid metabolism, or various endocrine disorders. Calculated LDL-cholesterol values are reported only when triglycerides are < 350 mg/dL; when triglycerides are > 350 mg/dL, calculated LDL-cholesterol are not reported.

Glucose measurement is for the quantitative measurement of the concentration of glucose in capillary whole blood that can be taken from the fingertip, ventral palm, dorsal hand, upper arm, forearm, calf and/or thigh by diabetic patients or health care professionals as an aid in the management of diabetes. Glucose measurement is not to be used for the diagnosis of or screening for diabetes or for neonatal use. Alternate site testing should be done during steady- state times when glucose is not changing rapidly.

LipidProTm Total Cholesterol control solution, HDL-cholesterol control solution, Triglyceride control solution, and Glucose control solution are used to test the precision of the LipidPro TM system and to detect systematic analytic deviations that may arise from reagent or analytical variation and they are for testing outside the body (in vitro diagnostic use only.) LipidPro TM control solutions are intended for in home and health care professionals use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K090405: Lipidpro System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K090405

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026