510(k) · Cleared
ClearedVenous Softbag Reservoirs with Softline Coating
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Maquet Cardiopulmonary, AG · DTN Reservoir, Blood, Cardiopulmonary Bypass
Cleared on Dec 23, 2009 as substantially equivalent to K070605 (Maquet Cardiopulmonary, AG, 2008) and 1 other predicate after a 282-day review. Its family tree reaches back 7 generations to 1992.
- Decided
- Dec 23, 2009
- Review
- 282 days
- Class
- Class II
- Product code
- DTN
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 7 generations to K922933 (1992). 21 ancestors in all, the oldest K920774 (1992). No later device cites it as a predicate yet.
- Root · 7 generations backK922933 Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc. · 1992
- 6 generations backK980600 D903 Avant Adult Hollow Fiber OxygenatorDideco S.P.A. · 1998
- 5 generations backK020351 D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber OxygenatorDideco S.P.A. · 2002
- 4 generations backK022450 Integrated Unit: Synthesis: Adult Membrane Oxygenator with…Dideco S.P.A. · 2002
- 3 generations backK031223 Synthesis Mimesys Adult Membrane OxygenatorDideco S.P.A. · 2003
- 2 generations backK073380 Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated…Sorin Group Italia S.R.L. · 2008 · Recalled
- 1 generation backK082117 Quadrox-I Adult with and Without Integrated Arterial Filter with…Maquet Cardiopulmonary, AG · 2009 · Recalled
- This deviceK090690 Venous Softbag Reservoirs with Softline CoatingMaquet Cardiopulmonary, AG · 2009
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K922933 | Sorin Monolyrh Integrated Membrane Lung | Sorin Biomedica, Fiat, USA, Inc. | 1992 | — |
| −6 | K980600 | D903 Avant Adult Hollow Fiber Oxygenator | Dideco S.P.A. | 1998 | — |
| −5 | K020351 | D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber Oxygenator | Dideco S.P.A. | 2002 | — |
| −4 | K022450 | Integrated Unit: Synthesis: Adult Membrane Oxygenator with Integrated Arterial… | Dideco S.P.A. | 2002 | — |
| −3 | K031223 | Synthesis Mimesys Adult Membrane Oxygenator | Dideco S.P.A. | 2003 | — |
| −2 | K073380 | Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated Areterial… | Sorin Group Italia S.R.L. | 2008 | 1 |
| −1 | K082117 | Quadrox-I Adult with and Without Integrated Arterial Filter with Softline… | Maquet Cardiopulmonary, AG | 2009 | 5 |
| 0 (this device) | K090690 | Venous Softbag Reservoirs with Softline Coating | Maquet Cardiopulmonary, AG | 2009 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1993 | 2 | 0 |
| 1995 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 2 | 0 |
| 2000 | 1 | 0 |
| 2001 | 2 | 0 |
| 2003 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DTN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DTN device
- #1 K251783 Inspire HCR and HCR DUAL cardiotomy reservoirsscore 12.4 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K070605 | Jostra Venous Softbag Reservoirs with and Without Safeline CoatingSummary page 1…(CFR 870.4400, product code: DTN) Legally Marketed Devices Jostra Venous Softbag Reservoirs with and without Safeline Coating (K070605), Quadrox-i Adult Microporous Membrane Oxygenator with and without i… | 2008 |
| * | K082117 | Quadrox-I Adult with and Without Integrated Arterial Filter with Softline Coating…Summary page 1…Quadrox-i Adult Microporous Membrane Oxygenator with and without integrated Arterial Filter (082117). Device Description The Venous Softbag Reservoir is used in extracorporeal circuits during cardiopulmonary bypass surgery and s… | 2009 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 12 months on median.
- 3 of the 21 ancestors have a recall of any class.
How does its category compare?
All DTN devicesDTN Reservoir, Blood, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DTN
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DTN
38in 2014
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DTN
2in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DTN
8in 2025
MAUDE reports naming product code DTN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 1 | 10 |
| 2008 | 1 | — | 1 | 8 |
| 2009 | 7 | 211 | 1 | 10 |
| 2010 | 1 | — | 0 | 18 |
| 2011 | 2 | — | 1 | 10 |
| 2012 | 0 | — | 0 | 17 |
| 2013 | 4 | 79 | 0 | 47 |
| 2014 | 3 | 38 | 0 | 52 |
| 2015 | 2 | — | 0 | 27 |
| 2016 | 0 | — | 1 | 6 |
| 2017 | 2 | — | 1 | 3 |
| 2018 | 0 | — | 2 | 4 |
| 2019 | 0 | — | 0 | 11 |
| 2020 | 0 | — | 0 | 6 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 0 | — | 0 | 7 |
| 2023 | 1 | — | 0 | 8 |
| 2024 | 2 | — | 0 | 10 |
| 2025 | 1 | — | 0 | 8 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Venous Softbag Reservoirs are indicated for use in extracorporeal circuits during cardiopulmonary bypass procedures in the field of open-heart-surgery. The utilization period of this device is restricted to six hours. Blood contact longer than 6 hours is not recommended. Application and use of the softbag reservoir is in the sole responsibility of the respective physician.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K090690 · printed Nov 4, 2026
Cite this page
510(k) Report. “K090690: Venous Softbag Reservoirs with Softline Coating.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K090690
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026