510(k) Report

510(k) · Cleared

Cleared

Quantum Perfusion Hybrid System

K241206510(k) TraditionalCleared Jul 18, 202479-day reviewClass II21 CFR 870.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Spectrum Medical S.R.L. · DTN Reservoir, Blood, Cardiopulmonary Bypass

Cleared on Jul 18, 2024 as substantially equivalent to K122844 (Sorin Group Italia S.R.L., 2012) after a 79-day review. Its family tree reaches back 6 generations to 1992.

Decided
Jul 18, 2024
Review
79 days
Class
Class II
Product code
DTN
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K922933 (1992). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK922933 Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc. · 1992
  2. 5 generations backK980600 D903 Avant Adult Hollow Fiber OxygenatorDideco S.P.A. · 1998
  3. 4 generations backK020351 D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber OxygenatorDideco S.P.A. · 2002
  4. 3 generations backK033323 D 903 Avant Adult Hollow Fiber Oxygenator and D 903 Avant 2…Dideco S.P.A. · 2004 · Recalled
  5. 2 generations backK121536 Inspire 8F Oxygenator with Integrated Arterial Filter & Hardshell…Sorin Group Italia S.R.L. · 2012
  6. 1 generation backK122844 Inspire 8F Dual Hollow Fiber Oxygenator with Integrated Arterial…Sorin Group Italia S.R.L. · 2012
  7. This deviceK241206 Quantum Perfusion Hybrid SystemSpectrum Medical S.R.L. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K922933Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc.1992—
−5K980600D903 Avant Adult Hollow Fiber OxygenatorDideco S.P.A.1998—
−4K020351D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber OxygenatorDideco S.P.A.2002—
−3K033323D 903 Avant Adult Hollow Fiber Oxygenator and D 903 Avant 2 PH.I.S.I.O. Adult…Dideco S.P.A.20041
−2K121536Inspire 8F Oxygenator with Integrated Arterial Filter & Hardshell ReservoirSorin Group Italia S.R.L.2012—
−1K122844Inspire 8F Dual Hollow Fiber Oxygenator with Integrated Arterial Filter and…Sorin Group Italia S.R.L.2012—
0 (this device)K241206Quantum Perfusion Hybrid SystemSpectrum Medical S.R.L.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200120
200410
FIG. 1 — Lineage of K241206, 1992–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTN device

  1. #1 K251783 Inspire HCR and HCR DUAL cardiotomy reservoirsscore 12.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122844Inspire 8F Dual Hollow Fiber Oxygenator with Integrated Arterial Filter and Hardshell…
Summary page 5
…Blood, Cardiopulmonary Bypass Regulatory Class: II Product Code: DTN,DTZ 510(k) Number: K122844 Reference Device Proprietary Name: Affinity Fusion™ Oxygenator with Integrated…
Sorin Group Italia S.R.L.2012—
†K183490Affinity NT Oxygenator, Affinity NT Oxygenator with Trillium Biosurface, Affinity NT…Medtronic, Inc.2019—

Also cleared against K122844: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 4 companies; a new generation was cleared every 5.7 years on median.
  • 1 of the 9 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K122844.

How does its category compare?

All DTN devices

DTN Reservoir, Blood, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · DTN

1in 2025

2007: 22008: 12009: 72010: 12011: 22013: 42014: 32015: 22017: 22023: 12024: 22025: 1
2007high 7 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTN

38in 2014

2009: 211 days median2013: 79 days median2014: 38 days median
2007high 211 (2009) · low 38 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTN

2in 2018

2007: 12008: 12009: 12011: 12016: 12017: 12018: 2
2007high 2 (2018) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DTN

8in 2025

2007: 102008: 82009: 102010: 182011: 102012: 172013: 472014: 522015: 272016: 62017: 32018: 42019: 112020: 62021: 122022: 72023: 82024: 102025: 8
2007high 52 (2014) · low 3 (2017)2025

MAUDE reports naming product code DTN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—110
20081—18
20097211110
20101—018
20112—110
20120—017
2013479047
2014338052
20152—027
20160—16
20172—13
20180—24
20190—011
20200—06
20210—012
20220—07
20231—08
20242—010
20251—08
20260—0—

What is it indicated for?

The Quantum Perfusion Hybrid System is intended to collect, defoam and filter venous and suction blood during cardiopulmonary bypass. The device is intended to be used for periods up to six hours. The device is intended for adult patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K241206: Quantum Perfusion Hybrid System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K241206

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026