Pogo Screw Instrumentation Tray

K091806510(k) TraditionalCleared Feb 22, 2010249-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fxdevices · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories

Cleared on Feb 22, 2010 as substantially equivalent to K040223 (Symmetry Medical USA, Inc., 2004) after a 249-day review. Its family tree reaches back 5 generations to 1984.

Decided
Feb 22, 2010
Review
249 days
Class
Class II
Product code
KCT
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K844002 (1984). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK844002 HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc. · 1984
  2. 4 generations backK980065 C/T Med-Systems Cassette SystemC/T Med System, Ltd. · 1998
  3. 3 generations backK990761 Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd. · 1999
  4. 2 generations backK012105 Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc. · 2002
  5. 1 generation backK040223 Polyvac Instrument Delivery SystemSymmetry Medical USA, Inc. · 2004
  6. This deviceK091806 Pogo Screw Instrumentation TrayFxdevices · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K844002HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc.1984—
−4K980065C/T Med-Systems Cassette SystemC/T Med System, Ltd.1998—
−3K990761Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd.1999—
−2K012105Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc.2002—
−1K040223Polyvac Instrument Delivery SystemSymmetry Medical USA, Inc.2004—
0 (this device)K091806Pogo Screw Instrumentation TrayFxdevices2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710
200110
200210
FIG. 1 — Lineage of K091806, 1984–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KCT device

  1. #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040223Polyvac Instrument Delivery System
Summary page 1
…Identification of Predicate or Legally Marketed Device The POGO Screw Instrumentation Tray is substantially equivalent tothe PolyVac Tray cleared under K(040223. 4. Device Description: The P000 Screw Instrumentation Tray is a custom autoclavable, compartmentalized, and perfor…
Symmetry Medical USA, Inc.2004—

Also cleared against K040223: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 6 companies; a new generation was cleared every 3.1 years on median.
  • None of the 9 ancestors has a recall.
  • 6 other devices also cite its predicate K040223.

How does its category compare?

All KCT devices

KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · KCT

11in 2025

2007: 32008: 62009: 62010: 122011: 62012: 102013: 82014: 112015: 152016: 122017: 102018: 152019: 182020: 142021: 182022: 112023: 102024: 82025: 112026 (partial year): 9
2007high 18 (2019) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KCT

205in 2025

2007: 199 days median2008: 182 days median2009: 89 days median2010: 202 days median2011: 117 days median2012: 236 days median2013: 131 days median2014: 169 days median2015: 151 days median2016: 182 days median2017: 211 days median2018: 192 days median2019: 187 days median2020: 134 days median2021: 185 days median2022: 137 days median2023: 94 days median2024: 106 days median2025: 205 days median2026 (partial year): 122 days median
2007high 236 (2012) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KCT

17in 2022

2010: 12011: 22013: 12014: 12016: 32017: 12021: 12022: 17
2007high 17 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KCT

50in 2025

2007: 22008: 82009: 52010: 32011: 32012: 22013: 62014: 52015: 62016: 162017: 32018: 222019: 152020: 662021: 262022: 82023: 302024: 182025: 50
2007high 66 (2020) · low 2 (2007)2025

MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007319902
2008618208
200968905
20101220213
2011611723
20121023602
2013813116
20141116915
20151515106
201612182316
20171021113
201815192022
201918187015
202014134066
202118185126
202211137178
20231094030
20248106018
202511205050
202691220—

What is it indicated for?

The POGO Screw Instrumentation Tray is intended for the protection, organization and delivery to the surgical field of the POGO Screw Instrumentation Set. The trays are not intended to maintain sterility by themselves. They are designed to, facilitate the pre-vacuum autoclave sterilization process when used in conjunction with a wrapping material (FDA cleared sterilization wrap). Wrapping materials are designed to allow air removal, steam…

Read the full statement (103 words)

The POGO Screw Instrumentation Tray is intended for the protection, organization and delivery to the surgical field of the POGO Screw Instrumentation Set.

The trays are not intended to maintain sterility by themselves. They are designed to, facilitate the pre-vacuum autoclave sterilization process when used in conjunction with a wrapping material (FDA cleared sterilization wrap). Wrapping materials are designed to allow air removal, steam penetration/evacuation and maintain the sterility of the internal components.

Sterilization Cycle Parameters

Method: Steam or Method: Steam

Cycle: Pre-vacuum Cycle: Gravity

Temperature: 1320C Temperature: 1320C

Exposure: 4 minutes Exposure: 15 minutes

Drying Time: 30 minutes Drying Time: 80 minutes

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091806: Pogo Screw Instrumentation Tray.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K091806

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026