510(k) Report

510(k) · Cleared

Cleared

Vitriblast, Thermoblast, Model VB-010, TB-010

K092107510(k) TraditionalCleared Jun 15, 2010336-day reviewClass II21 CFR 884.6180

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nidacon International AB · MQL Media, Reproductive

Cleared on Jun 15, 2010 as substantially equivalent to K060168 (Irvine Scientific Sales Co., Inc., 2006) and 1 other predicate after a 336-day review. Its family tree reaches back 2 generations to 2006.

Decided
Jun 15, 2010
Review
336 days
Class
Class II
Product code
MQL
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K060168 (2006). No later device cites it as a predicate yet.

  1. Root · 2 generations backK060168 Vitrification Freeze Kit, Vitrification Thaw KitIrvine Scientific Sales Co., Inc. · 2006
  2. 1 generation backK070135 Vitrifreeze Medium; Vitrithaw MediumFertipro NV · 2007
  3. This deviceK092107 Vitriblast, Thermoblast, Model VB-010, TB-010Nidacon International AB · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K060168Vitrification Freeze Kit, Vitrification Thaw KitIrvine Scientific Sales Co., Inc.2006—
−1K070135Vitrifreeze Medium; Vitrithaw MediumFertipro NV2007—
0 (this device)K092107Vitriblast, Thermoblast, Model VB-010, TB-010Nidacon International AB2010—
FIG. 1 — Lineage of K092107, 2006–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQL device

  1. #1 K251305 Ultra-Fast Vitri; Ultra-Fast Warmscore 14.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K060168Vitrification Freeze Kit, Vitrification Thaw Kit
Summary page 2
…welling during thawing and the removal of the ethylene glycol. Products claimed for substantial equivalence: * VitKit-Freeze and VitKit-Thaw from Irvine Scientific (K060 168) (DMSO, Ethylene glycol, Sucrose) * Vitri Freeze Kit from FertiPro (K070 135) (same as above + Ficoll) Comparison to predicat…
Irvine Scientific Sales Co., Inc.2006—
*K070135Vitrifreeze Medium; Vitrithaw Medium
Summary page 2
…d for substantial equivalence: * VitKit-Freeze and VitKit-Thaw from Irvine Scientific (K060 168) (DMSO, Ethylene glycol, Sucrose) * Vitri Freeze Kit from FertiPro (K070 135) (same as above + Ficoll) Comparison to predicate device The two predicate devices were compared in the following areas and were…
Fertipro NV2007—

Also cleared against K060168: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 2.8 years on median.
  • None of the 2 ancestors has a recall.
  • 6 other devices also cite its predicate K060168.

How does its category compare?

All MQL devices

MQL Media, Reproductive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · MQL

9in 2025

2007: 32008: 122009: 22010: 62011: 12012: 52014: 52015: 72016: 122017: 102018: 42019: 62020: 82021: 12022: 32023: 52024: 122025: 92026 (partial year): 3
2007high 12 (2008) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQL

225in 2025

2007: 212 days median2008: 151 days median2010: 235 days median2012: 253 days median2014: 142 days median2015: 87 days median2016: 170 days median2017: 113 days median2018: 94 days median2019: 170 days median2020: 257 days median2022: 316 days median2023: 199 days median2024: 195 days median2025: 225 days median2026 (partial year): 179 days median
2007high 316 (2022) · low 87 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQL

1in 2023

2012: 12020: 12021: 22022: 12023: 1
2007high 2 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQL

3in 2025

2012: 12013: 22014: 32016: 22023: 12024: 62025: 3
2007high 6 (2024) · low 0 (2007)2025

MAUDE reports naming product code MQL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007321200
20081215100
20092—00
2010623500
20111—00
2012525311
20130—02
2014514203
201578700
20161217002
20171011300
201849400
2019617000
2020825710
20211—20
2022331610
2023519911
20241219506
2025922503
202631790—

What is it indicated for?

VitriBlast is intended for ultra-rapid freezing of human blastocysts. This kit is designed for use with Nidacon's ThermoBlast Thaw Kit for optimal recovery of specimens.

This product is used for Assisted Reproductive Technology (ART.) procedures.

ThermoBlast is intended for the recovery of human blastocysts that have undergone ultra-rapid freezing using Nidacon's VitriBlast Kit. It is designed for optimal recovery of specimens.

This product is used for Assisted Reproductive Technology (A.R.T.) procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K092107: Vitriblast, Thermoblast, Model VB-010, TB-010.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K092107

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026