Cleared on Sep 18, 2009 as substantially equivalent to K080742 (Medcom GmbH, 2008) after a 21-day review. Its family tree reaches back 6 generations to 1981. 3 later devices descend from it.
- Decided
- Sep 18, 2009
- Review
- 21 days
- Class
- Class II
- Product code
- LHN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 6 generations to K803130 (1981). 25 ancestors in all. 3 later devices descend from it, 2 citing it directly.
- Root · 6 generations backK803130 Multix U. Bucky Table X-Ray UnitSiemens Corp. · 1981 · Recalled
- 5 generations backK971452 Multix Top/Pro Radiographic X-Ray TableSiemens Medical Solutions USA, Inc. · 1997 · Recalled
- 4 generations backK983732 Thorax FD and Multix FDSiemens Medical Solutions USA, Inc. · 1999 · Recalled
- 3 generations backK992794 Stingray DR, Model 1Infimed, Inc. · 1999
- 2 generations backK024147 Paxscan 4030 Medical Digital Imaging SystemVarian Medical Systems, Inc. · 2003
- 1 generation backK080742 Verisuite 1.6, Verisuite-Particle 1.6Medcom GmbH · 2008
- This deviceK092653 Verisuite and Verisuite-Particle, Version 1.8Medcom GmbH · 2009
- Descendant · cites it directly · 2 of its ownK133914 Verisuite 1.8, Verisuite-Particle 1.8, Verisuite, Verisuite-ParticleMedcom GmbH · 2014
- Descendant · cites it directly · 0 of its ownK181789 VeriSuiteMedcom GmbH · 2018
- Descendant · 2 generations on · 0 of its ownK171049 Real Time Image Gating System for Proton Beam Therapy SystemsHitachi, Ltd. Healthcare · 2017
Most influential descendants
Showing 3 of 3 · See all- K133914Verisuite 1.8, Verisuite-Particle 1.8, Verisuite, Verisuite-ParticleMedcom GmbH · 2014 · cites it directly2descendants
- K181789VeriSuiteMedcom GmbH · 2018 · cites it directly0descendants
- K171049Real Time Image Gating System for Proton Beam Therapy SystemsHitachi, Ltd. Healthcare · 2017 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K803130 | Multix U. Bucky Table X-Ray Unit | Siemens Corp. | 1981 | 1 |
| −5 | K971452 | Multix Top/Pro Radiographic X-Ray Table | Siemens Medical Solutions USA, Inc. | 1997 | 8 |
| −4 | K983732 | Thorax FD and Multix FD | Siemens Medical Solutions USA, Inc. | 1999 | 1 |
| −3 | K992794 | Stingray DR, Model 1 | Infimed, Inc. | 1999 | — |
| −2 | K024147 | Paxscan 4030 Medical Digital Imaging System | Varian Medical Systems, Inc. | 2003 | — |
| −1 | K080742 | Verisuite 1.6, Verisuite-Particle 1.6 | Medcom GmbH | 2008 | — |
| 0 (this device) | K092653 | Verisuite and Verisuite-Particle, Version 1.8 | Medcom GmbH | 2009 | — |
| +1 | K133914 | Verisuite 1.8, Verisuite-Particle 1.8, Verisuite, Verisuite-Particle | Medcom GmbH | 2014 | — |
| +1 | K181789 | VeriSuite | Medcom GmbH | 2018 | — |
| +2 | K171049 | Real Time Image Gating System for Proton Beam Therapy Systems | Hitachi, Ltd. Healthcare | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1988 | 1 | 0 |
| 1992 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 3 | 0 |
| 1997 | 1 | 0 |
| 1998 | 3 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2007 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LHN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LHN device
- #1 K260597 Virtue QAscore 15.4 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K080742 | Verisuite 1.6, Verisuite-Particle 1.6Summary page 1…VeriSuite-Particle 1.8 D. Predicate device Device trade name: VeriSuite 1.6 510(k) number: K080742 Company name: MedCom GmbH Classification Number: 892.5050… | 2008 |
What descends from it? (3)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 28 years and passes through 5 companies; a new generation was cleared every 3.3 years on median.
- 11 of the 25 ancestors have a recall of any class.
- Of its descendants, K133914 (Medcom GmbH, 2014) has gone furthest, with 2 descendants of its own.
- 1 other device also cites its predicate K080742.
How does its category compare?
All LHN devicesLHN System, Radiation Therapy, Charged-Particle, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · LHN
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LHN
190in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LHN
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LHN
11in 2025
MAUDE reports naming product code LHN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 2 | 0 |
| 2008 | 3 | 113 | 2 | 1 |
| 2009 | 5 | 69 | 0 | 5 |
| 2010 | 4 | 96 | 0 | 3 |
| 2011 | 1 | — | 0 | 1 |
| 2012 | 3 | 111 | 0 | 1 |
| 2013 | 3 | 70 | 0 | 1 |
| 2014 | 4 | 93 | 2 | 5 |
| 2015 | 3 | 53 | 1 | 2 |
| 2016 | 7 | 120 | 0 | 1 |
| 2017 | 4 | 173 | 5 | 7 |
| 2018 | 3 | 78 | 2 | 8 |
| 2019 | 2 | — | 0 | 3 |
| 2020 | 4 | 74 | 1 | 20 |
| 2021 | 0 | — | 1 | 24 |
| 2022 | 2 | — | 2 | 10 |
| 2023 | 2 | — | 1 | 7 |
| 2024 | 1 | — | 0 | 2 |
| 2025 | 3 | 190 | 0 | 11 |
| 2026 | 4 | 194 | 0 | — |
What is it indicated for?
The VeriSuite patient position verification system is used for verification and correction of the patient's position during a radiotherapy treatment with external beams or charged particles. It is based on stereoscopic X-ray images and DRRs calculated from a CT image series of the treatment region of the patient and information from the treatment planning.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K092653 · printed Nov 4, 2026
Cite this page
510(k) Report. “K092653: Verisuite and Verisuite-Particle, Version 1.8.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K092653
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026