510(k) Report

510(k) · Cleared

Cleared

2008 Hemodialysis Sorbent System

K093362510(k) AbbreviatedCleared Aug 13, 2010289-day reviewClass II21 CFR 876.5600

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Renal Solutions, Inc. · FKT System, Dialysate Delivery, Sorbent Regenerated

Cleared on Aug 13, 2010 as substantially equivalent to K070739 (Renal Solutions, Inc., 2007) and 1 other predicate after a 289-day review. Its family tree reaches back 3 generations to 1994. 1 later device descends from it.

Decided
Aug 13, 2010
Review
289 days
Class
Class II
Product code
FKT
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K921456 (1994). 4 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK921456 Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc. · 1994 · Recalled
  2. 2 generations backK994267 Fresenius 2008KFresenius Medical Care · 2000 · Recalled
  3. 1 generation backK080964 Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America · 2009 · Recalled
  4. This deviceK093362 2008 Hemodialysis Sorbent SystemRenal Solutions, Inc. · 2010
  5. Descendant · cites it directly · 0 of its ownK123835 2008 Hemodialysis Sorbent SystemRenal Solutions, Inc. · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K1238352008 Hemodialysis Sorbent SystemRenal Solutions, Inc. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K921456Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc.19943
−2K994267Fresenius 2008KFresenius Medical Care20005
−1K080964Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America20094
0 (this device)K0933622008 Hemodialysis Sorbent SystemRenal Solutions, Inc.2010—
+1K1238352008 Hemodialysis Sorbent SystemRenal Solutions, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K093362, 1994–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FKT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070739Allient Sorbent Hemodialysis System, Model# 1500
Summary page 3
…pproved for use; it is substantially equivalent to the Fresenius 2008T hemodialysis machine (K080964) and the Renal Solutions Allient® Sorbent Hemodialysis System (K070739). 2008 SorbentH-emodialysis System 510(k) Premarket Notification…
Renal Solutions, Inc.2007—
*K080964Fresenius Model 2008T Hemodialysis Machine
Summary page 3
…erates in a similar manner to standard hemodialysis systems currently approved for use; it is substantially equivalent to the Fresenius 2008T hemodialysis machine (K080964) and the Renal Solutions Allient® Sorbent Hemodialysis System (K070739). 2008 SorbentH-emodial…
Fresenius Medical Care North America20094

Also cleared against K070739: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K1238352008 Hemodialysis Sorbent SystemRenal Solutions, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 5.9 years on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K123835 (Renal Solutions, Inc., 2013) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K070739.

How does its category compare?

All FKT devices

FKT System, Dialysate Delivery, Sorbent Regenerated: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · FKT

1in 2013

2007: 12010: 12013: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FKT

Too few FKT 510(k)s in any year since 2007 to give a median.

Recalls per year · FKT

No recall names FKT since 2007.

Adverse event reports per year · FKT

1in 2012

2008: 12010: 12011: 12012: 1
2007high 1 (2008) · low 0 (2007)2025

MAUDE reports naming product code FKT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—01
20090—00
20101—01
20110—01
20120—01
20131—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The 2008 Sorbent System is intended for adult acute and chronic uremic patients in the presence of a healthcare practitioner where hemodialysis is prescribed on the order of a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K093362: 2008 Hemodialysis Sorbent System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K093362

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026