510(k) Report

510(k) · Cleared

Cleared

2008 Hemodialysis Sorbent System

K123835510(k) SpecialCleared Feb 15, 201364-day reviewClass II21 CFR 876.5600

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Renal Solutions, Inc. · FKT System, Dialysate Delivery, Sorbent Regenerated

Cleared on Feb 15, 2013 as substantially equivalent to K093362 (Renal Solutions, Inc., 2010) after a 64-day review. Its family tree reaches back 4 generations to 1994.

Decided
Feb 15, 2013
Review
64 days
Class
Class II
Product code
FKT
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K921456 (1994). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK921456 Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc. · 1994 · Recalled
  2. 3 generations backK994267 Fresenius 2008KFresenius Medical Care · 2000 · Recalled
  3. 2 generations backK080964 Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America · 2009 · Recalled
  4. 1 generation backK093362 2008 Hemodialysis Sorbent SystemRenal Solutions, Inc. · 2010
  5. This deviceK123835 2008 Hemodialysis Sorbent SystemRenal Solutions, Inc. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K921456Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc.19943
−3K994267Fresenius 2008KFresenius Medical Care20005
−2K080964Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America20094
−1K0933622008 Hemodialysis Sorbent SystemRenal Solutions, Inc.2010—
0 (this device)K1238352008 Hemodialysis Sorbent SystemRenal Solutions, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K123835, 1994–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FKT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K0933622008 Hemodialysis Sorbent System
Summary page 1
…rbent Regenerated Regulation Number 876.5600 Proprietary Name 2008 Sorbent System Unmodified Device 2008 Sorbent System (K093362) Reason for Submission Modification to existing device Device Description The 2008 Sorbent System is inte…
Renal Solutions, Inc.2010—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 5.9 years on median.
  • 3 of the 5 ancestors have a recall of any class.

How does its category compare?

All FKT devices

FKT System, Dialysate Delivery, Sorbent Regenerated: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · FKT

1in 2013

2007: 12010: 12013: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FKT

Too few FKT 510(k)s in any year since 2007 to give a median.

Recalls per year · FKT

No recall names FKT since 2007.

Adverse event reports per year · FKT

1in 2012

2008: 12010: 12011: 12012: 1
2007high 1 (2008) · low 0 (2007)2025

MAUDE reports naming product code FKT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—01
20090—00
20101—01
20110—01
20120—01
20131—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The 2008 Sorbent System is Intended for adult acute and chronic uremic patients In the presence of a healthcare practitioner where hemodialysis Is prescribed on the order of a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123835: 2008 Hemodialysis Sorbent System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123835

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026