Dimension Vista Loci CA 19-9 Flex Reagent Cartridge, and Dimension LOCI7 Calibrator with Model (S) K6457, and KC604

K100375510(k) TraditionalCleared Apr 6, 2011418-day reviewClass II21 CFR 866.6010

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics, Inc. · NIG System, Test, Carbohydrate Antigen (Ca19-9), For Monitoring And Management Of Pancreatic Cancer

Cleared on Apr 6, 2011 as substantially equivalent to K031393 (Bayer Healthcare, LLC, 2003) after a 418-day review. Its family tree reaches back 2 generations to 2002.

Decided
Apr 6, 2011
Review
418 days
Class
Class II
Product code
NIG
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K020566 (2002). No later device cites it as a predicate yet.

  1. Root · 2 generations backK020566 Fujirebio Diagnostics CA 19-9 RiaFujirebio Diagnostics,Inc. · 2002
  2. 1 generation backK031393 Bayer Advia Centaur CA 19-9 AssayBayer Healthcare, LLC · 2003 · Recalled
  3. This deviceK100375 Dimension Vista Loci CA 19-9 Flex Reagent Cartridge, and Dimension…Siemens Healthcare Diagnostics, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K020566Fujirebio Diagnostics CA 19-9 RiaFujirebio Diagnostics,Inc.2002—
−1K031393Bayer Advia Centaur CA 19-9 AssayBayer Healthcare, LLC20038
0 (this device)K100375Dimension Vista Loci CA 19-9 Flex Reagent Cartridge, and Dimension LOCI7…Siemens Healthcare Diagnostics, Inc.2011—
FIG. 1 — Lineage of K100375, 2002–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NIG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NIG device

  1. #1 K253528 Atellica IM CA 19-9 IIscore 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031393Bayer Advia Centaur CA 19-9 Assay
Summary page 1
…. The predicate device used to demonstrate substantial equivalence to the Dimension Vista® tOCl 7 Calibrator is the ADVIA Centaur® Calibrator 9 previously cleared under k031 393. G. Device Description: The CA19-9 method is a homogeneous, sandwich chemilurninescent immunoassay based on LOCI…
Bayer Healthcare, LLC20038

Also cleared against K031393: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 7.8 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • 1 other device also cites its predicate K031393.

How does its category compare?

All NIG devices

NIG System, Test, Carbohydrate Antigen (Ca19-9), For Monitoring And Management Of Pancreatic Cancer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · NIG

1in 2023

2011: 12019: 12020: 12023: 12026 (partial year): 1
2007high 1 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NIG

Too few NIG 510(k)s in any year since 2007 to give a median.

Recalls per year · NIG

2in 2016

2010: 12011: 12012: 12016: 2
2007high 2 (2016) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NIG

98in 2025

2007: 62008: 92009: 112010: 122011: 82012: 1,7852013: 1822014: 1172015: 292016: 692017: 982018: 582019: 1352020: 932021: 692022: 832023: 1292024: 1212025: 98
2007high 1,785 (2012) · low 6 (2007)2025

MAUDE reports naming product code NIG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—06
20080—09
20090—011
20100—112
20111—18
20120—11,785
20130—0182
20140—0117
20150—029
20160—269
20170—098
20180—058
20191—0135
20201—093
20210—069
20220—083
20231—0129
20240—0121
20250—098
20261—0—

What is it indicated for?

The LOCI 7 CAL is an in vitro diagnostic product for the calibration of the Cancer Antigen 19-9 (CA19-9) method on the Dimension Vista® System. The LOCI CA19-9 method is an in vitro diagnostic test for the quantitative measurement of the CA 19-9 tumor-associated antigen in human serum and lithium heparin and EDTA plasma on the Dimension Vista® System. Measurements of CA 19-9 are indicated for the serial measurement of CA19-9 to aid in managing patients…

Read the full statement (147 words)

The LOCI 7 CAL is an in vitro diagnostic product for the calibration of the Cancer Antigen 19-9 (CA19-9) method on the Dimension Vista® System.

The LOCI CA19-9 method is an in vitro diagnostic test for the quantitative measurement of the CA 19-9 tumor-associated antigen in human serum and lithium heparin and EDTA plasma on the Dimension Vista® System. Measurements of CA 19-9 are indicated for the serial measurement of CA19-9 to aid in managing patients diagnosed with cancers of the exocrine pancreas. The test is useful as an aid in monitoring of disease status in those patients having confirmed pancreatic cancer who have levels of serum CA 19-9 at some point in their disease process exceeding the median concentration determined for the apparently healthy cohort. CA 19-9 values must be interpreted in conjunction with all other clinical and laboratory data before a medical decision is determined.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100375: Dimension Vista Loci CA 19-9 Flex Reagent Cartridge, and Dimension LOCI7 Calibrator with Model (S) K6457, and KC604.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100375

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026