510(k) · Cleared
Recalled · Class II · 2013K-Shield Port Access Infusion Set with High Pressure Tubing
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Kawasumi Laboratories, Inc. · FPA Set, Administration, Intravascular
Cleared on Nov 18, 2010 as substantially equivalent to K060580 (Kawasumi Laboratories, Inc., 2006) and 1 other predicate after a 248-day review. Its family tree reaches back 7 generations to 2000. It has been recalled once.
- Decided
- Nov 18, 2010
- Review
- 248 days
- Class
- Class II
- Product code
- FPA
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 7 generations to K001901 (2000). 21 ancestors in all, the oldest K863606 (1986). No later device cites it as a predicate yet.
- Root · 7 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
- 6 generations backK012902 Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly…C.R. Bard, Inc. · 2001
- 5 generations backK031129 Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc. · 2003
- 4 generations backK034019 Poly Per-Q-Cath Picc CathetersC.R. Bard, Inc. · 2004 · Recalled
- 3 generations backK050931 6 FR DL Powerpicc CatheterC.R. Bard, Inc. · 2005
- 2 generations backK051672 PowerpiccBard Access Systems, Inc. · 2005 · Recalled
- 1 generation backK060812 Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex…C.R. Bard, Inc. · 2006 · Recalled
- This deviceK100720 K-Shield Port Access Infusion Set with High Pressure TubingKawasumi Laboratories, Inc. · 2010
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K001901 | Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline… | C.R. Bard, Inc. | 2000 | 2 |
| −6 | K012902 | Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath… | C.R. Bard, Inc. | 2001 | — |
| −5 | K031129 | Poly Per-Q-Cath Picc Catheters; Poly Radpicc | C.R. Bard, Inc. | 2003 | — |
| −4 | K034019 | Poly Per-Q-Cath Picc Catheters | C.R. Bard, Inc. | 2004 | 1 |
| −3 | K050931 | 6 FR DL Powerpicc Catheter | C.R. Bard, Inc. | 2005 | — |
| −2 | K051672 | Powerpicc | Bard Access Systems, Inc. | 2005 | 1 |
| −1 | K060812 | Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-Multiple | C.R. Bard, Inc. | 2006 | 1 |
| 0 (this device) | K100720 | K-Shield Port Access Infusion Set with High Pressure Tubing | Kawasumi Laboratories, Inc. | 2010 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1989 | 4 | 0 |
| 1991 | 1 | 0 |
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2004 | 2 | 0 |
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K060580 | K-Shield Port Access Infusion SetSummary page 1…21 CFR 880.5540. PRODUCT CODE NUMBER: FPA 3. PREDICATE DEVICE: Kawasumi Laboratories Port Access Infusion Set with Antineedle Stick Protector (K(060580), and, Bard Power Loc Safety Infusion Set (K(060812) 4. DESCRIPTION OF THE DEVICE: The K-Shield Port Access Infusion Set with Hi… | 2006 |
| * | K060812 | Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-MultipleSummary page 2…material. The technological characteristics of being able to withstand high pressure is substantially equivalent to the Bard device (K0608 12). The other identified differences do not have a significant impact on the safety or effectivenes… | 2006 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 25, 2013 | Class II | Z-0826-2014 | Device Design | Navilyst Medical has recalled a Port Kit with Access Infusion Set due to a possible breach of sterilization barrier. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 12 months on median.
- 11 of the 21 ancestors have a recall of any class.
- 1 other device also cites its predicate K060580.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
The K-Shield Port Access Infusion Set with High Pressure Tubing is an intravascular administration set with a non-coring Huber needle that is used to access an implanted medication port for solution infusion and blood sampling. The high pressure tubing allows for the injection of contrast media with a power injector to 300 psi into an implanted port indicated for use with a power injector. The device is supplied sterile, non-pyrogenic and for single use.…
Read the full statement (112 words)
The K-Shield Port Access Infusion Set with High Pressure Tubing is an intravascular administration set with a non-coring Huber needle that is used to access an implanted medication port for solution infusion and blood sampling. The high pressure tubing allows for the injection of contrast media with a power injector to 300 psi into an implanted port indicated for use with a power injector. The device is supplied sterile, non-pyrogenic and for single use. The port access infusion sets are designed with an integral antineedle stick protector that provides a safety feature intended to minimize accidental needle stick injuries when the needle is activated during removal from the patient's implanted medication port.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K100720 · printed Nov 6, 2026
Cite this page
510(k) Report. “K100720: K-Shield Port Access Infusion Set with High Pressure Tubing.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100720
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026