510(k) · Cleared
ClearedK-Shield Arterial Venous Fistula Set with Antineedle Stick Protector
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Kawasumi Laboratories, Inc. · FMI Needle, Hypodermic, Single Lumen
Cleared on Nov 3, 2010 as substantially equivalent to K073257 (Kawasumi Laboratories, Inc., 2008) and 2 other predicates after a 26-day review. Its family tree reaches back 2 generations to 1997. 1 later device descends from it.
- Decided
- Nov 3, 2010
- Review
- 26 days
- Class
- Class II
- Product code
- FMI
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 2 generations to K970259 (1997). 7 ancestors in all, the oldest K873421 (1987). 1 later device descends from it, 1 citing it directly.
- Root · 2 generations backK970259 E-Z Set Infusion Set/Saf-T E-Z Set Infusion SetBecton Dickinson Vascular Access, Inc. · 1997
- 1 generation backK980414 Vacutainer Brand Safety-Lok Blood Collection Set Model Multiple…Bd Becton Dickinson Vacutainer Systems Preanalytic · 1998 · Recalled
- This deviceK102994 K-Shield Arterial Venous Fistula Set with Antineedle Stick ProtectorKawasumi Laboratories, Inc. · 2010
- Descendant · cites it directly · 0 of its ownK172957 Kawasumi Laboratories Blood Drawing Kit (BDK) SystemKawasumi Laboratories, Inc. · 2018
Most influential descendants
Showing 1 of 1 · See all- K172957Kawasumi Laboratories Blood Drawing Kit (BDK) SystemKawasumi Laboratories, Inc. · 2018 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K970259 | E-Z Set Infusion Set/Saf-T E-Z Set Infusion Set | Becton Dickinson Vascular Access, Inc. | 1997 | — |
| −1 | K980414 | Vacutainer Brand Safety-Lok Blood Collection Set Model Multiple, Vacutainer… | Bd Becton Dickinson Vacutainer Systems Preanalytic | 1998 | 1 |
| 0 (this device) | K102994 | K-Shield Arterial Venous Fistula Set with Antineedle Stick Protector | Kawasumi Laboratories, Inc. | 2010 | — |
| +1 | K172957 | Kawasumi Laboratories Blood Drawing Kit (BDK) System | Kawasumi Laboratories, Inc. | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1994 | 1 | 0 |
| 2000 | 2 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FMI device
- #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K073257 | Kawasumi Laboratories Large Wing Sets with Antineedle Stick ProtectorSummary page 1…lass 1I, Codified at 21 CFR 880.5570. PRODUCT CODE NUMBER: PFM1 3. PREDICATE DEVICE: Kawasumi Laboratories Large Wing Sets with Antineedle Stick Protector (K073257), Medisystems Masterguard (K(932074) and the Becton Dickinson Vacutainer Brand Safety-Lok Blood Collection Set (K980414 )… | 2008 |
| * | K932074 | Medisystems Apheresis Needle with GuardSummary page 2…tified predicate devices and performs as well as the predicate devices Large Wing Sets with Antineedle Stick Protector (073257), Medisystems Masterguard (K932074) and the Becton Dickinson Vacutainer Safety- Lok Blood Collection Set (980414) for their intended use. DE… | 1994 |
| * | K980414 | Vacutainer Brand Safety-Lok Blood Collection Set Model Multiple, Vacutainer Brand Blood…Summary page 1…with Antineedle Stick Protector (K073257), Medisystems Masterguard (K(932074) and the Becton Dickinson Vacutainer Brand Safety-Lok Blood Collection Set (K980414 ). 4. DESCRIPTION OF THE DEVICE: The K-Shield Arterial Venous Fistula Set with Antineedle Stick Protector, K-Shield Bl… | 1998 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K172957 | Kawasumi Laboratories Blood Drawing Kit (BDK) System | 2018 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 12.7 years on median.
- 1 of the 7 ancestors has a recall of any class.
- Of its descendants, K172957 (Kawasumi Laboratories, Inc., 2018) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K073257.
How does its category compare?
All FMI devicesFMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · FMI
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FMI
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FMI
1in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · FMI
2,424in 2025
MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 71 | 2 | 208 |
| 2008 | 10 | 85 | 4 | 177 |
| 2009 | 7 | 177 | 3 | 263 |
| 2010 | 15 | 119 | 79 | 249 |
| 2011 | 12 | 113 | 5 | 240 |
| 2012 | 17 | 107 | 1 | 215 |
| 2013 | 11 | 87 | 1 | 255 |
| 2014 | 14 | 155 | 3 | 287 |
| 2015 | 10 | 89 | 1 | 567 |
| 2016 | 20 | 217 | 0 | 941 |
| 2017 | 9 | 253 | 16 | 1,547 |
| 2018 | 20 | 176 | 0 | 2,398 |
| 2019 | 12 | 186 | 5 | 4,896 |
| 2020 | 11 | 263 | 3 | 4,245 |
| 2021 | 18 | 143 | 7 | 4,532 |
| 2022 | 23 | 189 | 0 | 4,885 |
| 2023 | 18 | 112 | 2 | 4,986 |
| 2024 | 3 | 90 | 1 | 4,053 |
| 2025 | 11 | 141 | 0 | 2,424 |
| 2026 | 12 | 119 | 1 (1) | — |
What is it indicated for?
Name: Kawasumni A.V. Fistula Set Intended Use: This device is intended to be used to access a vein or artery and to be used as a conduit to connect to blood tubing lines for performing patient hemodialysis. The device is designed with an integral antineedle stick protector that provides a safety feature intended to minimize accidental needle stick injuries when the device is activated during removal from the patient's vein or artery. Name: Kawasumni…
Read the full statement (228 words)
Name: Kawasumni A.V. Fistula Set
Intended Use: This device is intended to be used to access a vein or artery and to be used as a conduit to connect to blood tubing lines for performing patient hemodialysis. The device is designed with an integral antineedle stick protector that provides a safety feature intended to minimize accidental needle stick injuries when the device is activated during removal from the patient's vein or artery.
Name: Kawasumni Laboratory Blood Drawing Kit
Intended Use: This is a therapeutic device used to access a patients vein for blood removal from the patient to a blood bag reservoir to aid in the treatment of a disease or other condition. This device is not intended for blood transfusions. The device is designed with an integral antineedle stick protector that provides a safety feature intended to minimize accidental needle stick injuries when the device is activated during removal from the patient's vein.
Name: Kawasumi Laboratories Phlebotomy Set
Intended Use: This device is intended to be used to access a patient's vein and as a conduit for blood removal to a vacuum bottle to aid in the treatment of a disease or other condition. The device is designddi with an integral antineedle stick protector that provides a safety feature intended to minimize accidental needle stick injuries when the device is activated during removal from the patient's vein.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K102994 · printed Nov 6, 2026
Cite this page
510(k) Report. “K102994: K-Shield Arterial Venous Fistula Set with Antineedle Stick Protector.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102994
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026